Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Yield instrument

The attraction of SFC-MS or HPLC-MS combinations led to significant interest in the late 1960 s and early 1970 s. The early dominance of HFLC technology, dictated the emphasis on HFLC-MS development. While these efforts have shown considerable success, they have not yet yielded instrumentation comparable to GC-MS in usefulness. [Pg.264]

That is, a money market product quoted as a yield instrument, similar to a bank deposit or a certificate of deposit. The other class of money market products are discount instruments such as a Treasury bill or commercial paper. [Pg.313]

Each corporate bond will only be exposed to one of these factors, with an exposure that will typically increase with the bond s maturity. A rule of thumb is that it will be comparable to the bond s exposure to the shift factor. The spread risk of almost all AAA, AA, and A rated bonds will be less than their interest rate risk, and it is only for BBB rated bonds and in some very specific market sectors such as Energy and Telecoms that spread risk starts exceeding benchmark risk. Spread risk is by far the dominant source of systematic risk for high-yield instruments. [Pg.737]

Specific returns are residual returns not explained by common factors. Common factors returns are typically larger than specific returns for higher quality investment-grade instruments this is no longer the case in the lower portion of the investment grade segment and for high-yield instruments. [Pg.739]

A microwave pulse from a tunable oscillator is injected into the cavity by an anteima, and creates a coherent superposition of rotational states. In the absence of collisions, this superposition emits a free-mduction decay signal, which is detected with an anteima-coupled microwave mixer similar to those used in molecular astrophysics. The data are collected in the time domain and Fourier transfomied to yield the spectrum whose bandwidth is detemimed by the quality factor of the cavity. Hence, such instruments are called Fourier transfomi microwave (FTMW) spectrometers (or Flygare-Balle spectrometers, after the inventors). FTMW instruments are extraordinarily sensitive, and can be used to examine a wide range of stable molecules as well as highly transient or reactive species such as hydrogen-bonded or refractory clusters [29, 30]. [Pg.1244]

A connnon approach has been to measure the equilibrium constant, K, for these reactions as a fiinction of temperature with the use of a variable temperature high pressure ion source (see section (Bl.7.2)1. The ion concentrations are approximated by their abundance in the mass spectrum, while the neutral concentrations are known from the sample mlet pressure. A van t Hoff plot of In K versus /T should yield a straight Ime with slope equal to the reaction enthalpy (figure B1.7.11). Combining the PA with a value for basicityG at one temperature yields a value for A.S for the half-reaction involving addition of a proton to a species. While quadnipoles have been tire instruments of choice for many of these studies, other mass spectrometers can act as suitable detectors [19, 20]. [Pg.1343]

Using a guided ion beam instrument the translational energy dependent reaction cross sections of endothemiic fragmentation processes can be detemiined [32]. Modelling these cross sections ultimately yields their energy tln-esholds and a great deal of valuable themiochemical infomiation has been derived with this teclmique. Precision of 0.2 eV can be obtained for reaction tln-esholds. Bimolecular reactions can also be studied and reaction enthalpies derived from the analysis of the cross section data. [Pg.1346]

In sunnnary, the SFA is a versatile instrument that represents a unique platfonu for many present and fiiture implementations. Unlike any other experimental teclmique, the SFA yields quantitative insight into molecular dimensions, structures and dynamics under confinement. [Pg.1738]

Solid phase peptide synthesis does not solve all purification problems however Even if every coupling step m the ribonuclease synthesis proceeded in 99% yield the product would be contaminated with many different peptides containing 123 ammo acids 122 ammo acids and so on Thus Memfield and Gutte s six weeks of synthesis was fol lowed by four months spent m purifying the final product The technique has since been refined to the point that yields at the 99% level and greater are achieved with current instrumentation and thousands of peptides and peptide analogs have been prepared by the solid phase method... [Pg.1142]

Fixed-product ion scans (sector instruments). High-voltage scan or linked scan at constant B /E. Both techniques give a spectrum of all precursor (parent) ions that fragment to yield a preselected product (daughter) ion. [Pg.435]

The actual yield may be obtained from algebraic calculations or trial-and-error calculations when the heat effects in the process and any resultant evaporation are used to correc t the initial assumptions on calculated yield. When calculations are made by hand, it is generally preferable to use the trial-and-error system, since it permits easy adjustments for relatively small deviations found in practice, such as the addition of wash water, or instrument and purge water additions. The following calculations are typical of an evaporative ciy/staUizer precipitating a hydrated salt, if SI units are desired, kilograms = pounds X 0.454 K = (°F 459.7)/I.8. [Pg.1654]

When a test run is performed using the actual materials for the toll, it is a prime opportunity for the toller and the client to document the capability of the equipment, instrumentation, and process steps. During such a test, frequency of sampling may be increased, additional analyses performed and yield capabilities checked to find the optimum setpoints and timing for the toll process. Health, safety and environmental staff may choose to provide close coverage of the test run to evaluate areas for improvement during the actual startup and long term operation. [Pg.103]

None of the foregoing methods will tell the frequency or duration of exposure of any receptor to irritant or odorous gases when each such exposure may exceed the irritation or odor response threshold for only minutes or seconds. The only way that such an exposure can be measured instrumentally is by an essentially continuous monitoring instrument, the record from which will yield not only this kind of information but also all the information required to assess hourly, daUy, monthly, and annual phenomena. Continuous monitoring techniques may be used at a particular location or involve remote sensing techniques. [Pg.48]

You should review the contract and the detail specifications to identify whether your existing controls will regulate quality within the limits required. You may need to change the limits, the standards, the techniques, the methods, the environment, and the instruments used to measure quality characteristics. One technique may be to introduce Just-in-time as a means of overcoming storage problems and eliminating receipt inspection. Another technique may be Statistical Process Control as a means of increasing the process yield. The introduction of these techniques needs to be planned and carefully implemented. [Pg.192]


See other pages where Yield instrument is mentioned: [Pg.303]    [Pg.303]    [Pg.908]    [Pg.313]    [Pg.1689]    [Pg.303]    [Pg.303]    [Pg.908]    [Pg.313]    [Pg.1689]    [Pg.286]    [Pg.1330]    [Pg.767]    [Pg.655]    [Pg.98]    [Pg.104]    [Pg.110]    [Pg.199]    [Pg.283]    [Pg.284]    [Pg.479]    [Pg.417]    [Pg.2058]    [Pg.199]    [Pg.205]    [Pg.209]    [Pg.77]    [Pg.203]    [Pg.286]    [Pg.325]    [Pg.356]    [Pg.573]    [Pg.612]    [Pg.226]    [Pg.66]    [Pg.10]    [Pg.241]    [Pg.249]    [Pg.28]   
See also in sourсe #XX -- [ Pg.313 ]




SEARCH



High yield instruments

Instrumentation 74 yield strength

Money market yield instrument

© 2024 chempedia.info