Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Remote damage

Passive piezoelectric sensors can also be applied to detect cracking and crack growth via acoustic emission or to identify damage proceedings via impact detection. Active piezoelectric sensors in SHM structures are suited for the detection of remote damage via pulse-echo, pulse-transmission and phased-array methods or for the identification of damages nearby the sensors via high-frequency electromechanical impedance methods. [Pg.362]

A knowledge of the molecular composition of a petroleum also allows environmentalists to consider the biological impact of environmental exposure. Increasingly, petroleum is being produced in and transported from remote areas of the world to refineries located closer to markets. Although only a minuscule fraction of that oil is released into the environment, the sheer volume involved has the potential for environmental damage. Molecular composition can not only identify the sources of contamination but also aids in understanding the fate and effects of the potentially hazardous components (7). [Pg.164]

Improved sensors allow computer monitoring of the system for safety and protection of the equipment from damage. Sensors include lubrication-flow monitors and alarms, bearing-temperature sensors, belt scales, rotation sensors, and proximity sensors to detect ore level under the crusher. The latter prevent jamming of the output with too high an ore level, and protect the conveyor from impact of lumps with too low an ore level. Motion detectors assure that the conveyor is moving. Control applied to crusher systems including conveyors can facilitate use of mobile crushers in quarries and mines, since these can be controlled remotely by computer with reduced labor. [Pg.1845]

The cathodic protection of pipelines is best monitored by an intensive measurement technique according to Section 3.7, by an off potential survey eveiy 3 years and by remote monitoring of pipe/soil potentials. After installation of parallel pipelines, it can be ascertained by intensive measurements whether new damage of the pipe coating has occurred. These measurements provide evidence of possible external actions that can cause mechanical damage. [Pg.288]

Check valves are required in the piping system at any point where backflow of gas after a shutdown has the ability to restart the compressor, running it backwards or, for that matter, even in the normal direction. Reverse rotation is totally bad, as many components of the various compressor types are not designed for reverse rotation, and there is some possibility, generally remote, that the compressor could reach a destructive over speed. Forward rotation is bad primarily because the intent was to stop the compressor, and it is now operating out of control. This is a problem, particularly if the shutdown was caused by a compressor failure indication, and the need to stop was to prevent further damage. In this mode, it is unlikely that the compressor can attain an overspeed condition. An application with a high potential for backflow is the parallel operation of two or more compressors. [Pg.472]

There are several suppliers of electron accelerators suitable for remote repair of composites, including Varian, Siemans, and Schonberg. At present, the only manufacturer of suitable portable electron accelerators is Schonberg Radiation Corporation of Santa Clara, California. Field repair of damaged aircraft components can be accomplished with a remotely controlled, truck-mounted accelerator. Table 13 gives the characteristics for several electron accelerators, all portable, supplied by Schonberg. Fig. 5 shows a schematic layout of a 10-MeV accelerator... [Pg.1030]

The technology to routinely cure applied adhesives for repairing damaged composite structures at remote repair stations is currently available. There are already systems that use portable accelerators for X-ray radiographic inspection of aircraft components [43]. Fig. 6 shows a conceptual picture of a portable accelerator unit that would contain the power unit, vacuum systems, and computer... [Pg.1030]

If the pump had been fitted with a remotely operated emergency isolation valve as recommended in Section 7.2.1, the leak could have been stopped quickly. Damage would have been slight. As it was, the unit shut dow n for five weeks. [Pg.301]

Groundbeds remote from the structure can be considered but usually with this type of installation problems arise due to damage to the connecting cable by ships anchors, etc. The calculation of rectifier voltage/anode resistance is exactly as described for impressed current pipeline installations except that the voltage required is very small because of the low resistance of the electrolyte—normally 20-3612 cm for typical sea-water. [Pg.221]

However, when a problem is particularly difficult or only limited time exists, consider a new and imaginative approach with techniques that previously generated creative ideas. First generate as many ideas as possible that may be even remotely related to the problem. During the idea-generating phase it is of critical importance to be totally positive no ideas are bad. Evaluation comes later, so do not attempt to provide creativity and evaluation at the same time it could be damaging to your creativity. Look for quantity of ideas, not quality, at this point. Now all ideas are good the best will become obvious later. [Pg.587]

Chemical spills in the laboratory may be hazardous, damaging to flooring and furniture finishes, or simply messy to clean up. Laboratory equipment houses and distributors of safety equipment carry a variety of clean-up kits made for specific types of spills, depending on the types of chemicals handled. Generally, the kits contain absorbents or neutralizers, or a combination of the two, plus instructions for use. Kits should be stored as close as possible to where spills are likely to occur and not in a remote storeroom. Instructions must be kept with the kits, not in a file cabinet. Quick action in case of a spill is important in reducing both hazards and damage. [Pg.44]

DNA CT also permits chemistry at a distance. Oxidative DNA damage and thymine dimer repair can proceed in a DNA-mediated reaction initiated from a remote site. These reactions too are sensitive to intervening DNA dynamical structure, and such structures can serve to modulate DNA CT chemistry. The sensitivity of DNA CT to base pair stacking also provides the basis for the design of new DNA diagnostics, tools to detect mutations in DNA and to probe protein-DNA interactions. [Pg.121]

In addition to the generation of platelets, hydrogenation of silicon also induces electronic deep levels in the band gap. As in the case of platelet formation, these defects are considered to be unrelated to either plasma or radiation damage because they can be introduced with a remote hydrogen plasma. Comparison of depth distributions and annealing kinetics of the platelets and gap states has been used to a limited extent to probe the relationship among these manifestations of H-induced defects. [Pg.146]

When more than one pump is installed, they should be coordinated to start in sequence, since immediate start up of all pumps may not be necessary and could cause damage to the system. Depending on the number of pumps available, they can be set to startup on sequentially decreasing fire main set points. All fire water pumps should be able to be started from remote activation switches located in manned control rooms. [Pg.207]


See other pages where Remote damage is mentioned: [Pg.284]    [Pg.393]    [Pg.449]    [Pg.124]    [Pg.236]    [Pg.97]    [Pg.352]    [Pg.1686]    [Pg.223]    [Pg.256]    [Pg.313]    [Pg.268]    [Pg.926]    [Pg.237]    [Pg.140]    [Pg.84]    [Pg.84]    [Pg.240]    [Pg.133]    [Pg.83]    [Pg.118]    [Pg.203]    [Pg.77]    [Pg.97]    [Pg.73]    [Pg.181]    [Pg.521]    [Pg.97]    [Pg.21]    [Pg.38]    [Pg.129]    [Pg.143]    [Pg.145]    [Pg.146]    [Pg.318]   
See also in sourсe #XX -- [ Pg.362 ]




SEARCH



Remote

© 2024 chempedia.info