Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Recovery time

Clinical evaluation is underway to test transvenous electrodes. Transvenous leads permit pacemakers to be implanted under local anesthesia while the patient is awake, greatly reducing recovery time and risk. As of 1996, the generation of implantable defibrillators requires a thoracotomy, a surgical opening of the chest, in order to attach electrodes to the outside of the heart. Transvenous electrodes would allow cardiologists to perform pacemaker procedures without a hospital or the use of general anesthesia. [Pg.181]

The Class I antiarrhythmic agents inactivate the fast sodium channel, thereby slowing the movement of Na" across the cell membrane (1,2). This is reflected as a decrease in the rate of development of phase 0 (upstroke) depolarization of the action potential (1,2). The Class I agents have potent local anesthetic effects. These compounds have been further subdivided into Classes lA, IB, and IC based on recovery time from blockade of sodium channels (11). Class IB agents have the shortest recovery times (t1 ) Class lA compounds have moderate recovery times (t 2 usually <9 s) and Class IC have the longest recovery times (t 2 usually >9 s). [Pg.112]

During turn-on, the transition is controlled by the forward recovery characteristic of the selected rectifier. The forward recovery time (q ) is the time it takes... [Pg.137]

Creep strain when load is removed Recovery time... [Pg.201]

Period Basic working week, e.g. <40 hr/wk, 48 wk/yr plus overtime therefore intermittent elimination and recovery times. Holidays excepted Continual unless area vacated therefore elimination and recovery depend on irregular periods of low/ zero concentrations... [Pg.502]

Tests have shown that when total strain is plotted against the logarithm of the total creep time (ie NT or total experimental time minus the recovery time) there is a linear relationship. This straight line includes the strain at the end of the first creep period and thus one calculation, for say the 10th cycle allows the line to be drawn. The total creep strain under intermittent loading can then be estimated for any combinations of loading/unloading times. [Pg.106]

The total creep strain after the stress of 10.5 MN/m has been applied for the 11th time would be 0.121 -I- 0.747 = 0.868%. Now tests have shown that a plot of total creep strain plotted against the logarithm of the total creep time (i.e. ignoring the recovery times) is a straight line which includes the point edT). [Pg.109]

Loss of offsite power at nuclear power plants is addressed in EPRI NP-2301, 1982 giving data on the frequency of offsite power loss and subsequent recoveiy at nuclear power plants. Data analysis includes point estimate frequency with confidence limits, assuming a constant rate of occurrence. Recovery time is analyzed with a lognormal distribution for the time to recover. [Pg.157]

Suspend mode This mode, also known as sleep mode, has the lowest power level (without being off) but has a longer recovery time than for standby. [Pg.901]

Some PCs qualify for a second standard of 15 percent of the rating of the power supply, usually at least 3Q W. For monitors, an initial low-power mode of 15 W is also required. (2) "NA" means hot applicable," which means that no requirement exists. (3) Additional Tier 2 requirement for copiers includes a required recovery time of 30 seconds for midspeed copiers (recommended for high speed copiers). [Pg.902]

Comparing the two optical transduction techniques (absorption or SPR) used in this work, we can conclude that SPR technique appears to be more suitable for gas sensing even if it presents some limitation regarding the suitable film thickness for SPR excitation. Moreover, the response and recovery times during the anal5fle/sensing layer interaction appears shortest in the case of optical absorption measurements. Further investigations are in... [Pg.285]

In addition to minimizing the acute inflammatory response, rest prevents additional injury to the affected area.13 The properties of the muscle-tendon unit are altered during the acute injury, with limitations on the ability of the muscles and tendons to stretch. Early activity predisposes a patient to further injury, but prolonged inactivity can lengthen recovery times. [Pg.902]

Recently, a robust, sensitive, and versatile HMBC experiment for rapid structure elucidation has been proposed. The suggested IMPACT-HMBC experiment eliminates the weaknesses of the basic HMBC experiment and the overall performance of the pulse sequence is improved significantly. In addition, it can be recorded with short recovery times, which is useful in routine analysis by NMR when the experimental time is limited. [Pg.343]

Recovery time from this operation can last anywhere from six to eight weeks. As soon as the patient can begin to eat solid food, he or she must learn how to eat again. The stomach has essentially become a small pouch and cannot hold the same amount of food that it used to (Figure 8.2). Patients must eat a healthier diet after this surgery they are much less able to tolerate a diet high in fat. Overall,... [Pg.99]

After the detection of a single photon, PMTs need a specific recovery time before they are sensitive again. During this deadtime, no photons can be detected. Because of the stochastic nature... [Pg.120]

Response and recovery times of NO sensors are extremely important for their use in vivo. Theoretically, since the rate of mass transport at a microelectrode is very... [Pg.35]


See other pages where Recovery time is mentioned: [Pg.182]    [Pg.228]    [Pg.169]    [Pg.59]    [Pg.104]    [Pg.902]    [Pg.53]    [Pg.140]    [Pg.270]    [Pg.10]    [Pg.145]    [Pg.111]    [Pg.36]    [Pg.165]    [Pg.240]    [Pg.906]    [Pg.282]    [Pg.80]    [Pg.140]    [Pg.198]    [Pg.274]    [Pg.274]    [Pg.75]    [Pg.198]    [Pg.346]    [Pg.647]    [Pg.77]    [Pg.92]    [Pg.88]    [Pg.268]    [Pg.141]   
See also in sourсe #XX -- [ Pg.200 ]

See also in sourсe #XX -- [ Pg.322 , Pg.326 , Pg.341 ]

See also in sourсe #XX -- [ Pg.15 , Pg.19 , Pg.24 , Pg.37 , Pg.38 , Pg.53 , Pg.104 , Pg.143 , Pg.150 , Pg.160 , Pg.197 , Pg.362 , Pg.364 , Pg.380 ]

See also in sourсe #XX -- [ Pg.165 ]

See also in sourсe #XX -- [ Pg.607 ]




SEARCH



Conjugated polymer nanocomposites recovery time

Course-time recoveries, labeled

Energy recovery time

Inversion-recovery spin-lattice relaxation time

Recovery rate Residence time

Recovery time objective

Recovery times in pulse NMR

Response and recovery times

Response-recovery time

Short time inversion recovery

Sinus node recovery time

Time Frame for NAPL Recovery

Time-course recovery

© 2024 chempedia.info