Quantitation sensitivity

Nevertheless, the quantitative sensitivity when using ASV is of the order of 10 °, or even 10 , mol dm of analyte. This improvement over other coulo-metric methods arises solely from the pre-concentration by a factor of up to 1000 times, thereby decreasing the relative magnitude of charging currents. [Pg.188]

Since a larger sample volume is presumed to be probed, the use of transmission mode has led to simpler, more accurate models requiring fewer calibration samples [50]. Scientists at AstraZeneca found that with a transmission Raman approach as few as three calibration samples were required to obtain prediction errors nearly equivalent to their full model [42]. For a fixed 10-s acquisition time, the transmission system had prediction errors as much as 30% less than the WAI system, though both approaches had low errors. It is hoped that this approach in combination with advanced data analysis techniques, such as band target entropy minimization (BTEM) [51], might help improve Raman s quantitative sensitivity further. [Pg.210]

Poly(p-formyloxystyrene) was also subjected to quantitative sensitivity analysis using a calibrated multidensity resolution mask. A plot of the normalized thickness remaining as a function of dose is provided in Figure 11. The resist exhibits a sensitivity of approximately 70 mJ/cm2 in the deep UV and has a contrast ( ) comparable to that of the classical diazonaphtoquinone-novolac positive resists that are commonly employed in semiconductor manufacturing. [Pg.282]

The reliability of a method can be determined by assessing certain method performance criteria including, specificity, accuracy, precision, limit of detection and quantitation, sensitivity, applicability, and practicability as appropriate (13). This very often requires that an extensive collaborative study be undertaken to obtain the necessary data. Methods that have successfully undergone this performance review testing have been considered to be validated for the purpose of the analysis (14). [Pg.418]

Ramirez-MuRoz, J. Qualitative and Quantitative Sensitivity in Flame Photometry. Talanta 13, 87 (1966). [Pg.110]

Ramirez-Munoz, J., N. Shifrin, and A. Hell Quantitative Sensitivity in Atomic-Absorption Spectroscopy. Microchem. J. 11, 204 (1966). [Pg.111]

PCR is a very powerful technique, providing a sizable amount of DNA from a trace of a DNA sample. Hence it would be natural to expect that the trace amount of starting DNA can be quantitated sensitively from the amount of the finally-obtained PCR product. However, this type of quantitation based on the end-point detection is not reliable because of the saturation effects of PCR. This problem has been overcome by real-time PCR, which monitors PCR amplification in real time and enables accurate quantitation from the kinetics of the exponential phase. Real-time PCR thereby provides a highly sensitive and specific quantitation method for nucleic acids. [Pg.203]

Sensitivity analysis can be either qualitative or quantitative. In a qualitative analysis, the assessor identifies the uncertainties affecting the assessment and forms a judgement of their relative importance. Such an evaluation is implicit in the qualitative approaches to assessing uncertainty, described in section 5.1. This is subjective and therefore less reliable than a quantitative sensitivity analysis. However, it is a practical first step for identifying the most important uncertainties as a focus for quantitative analysis. [Pg.58]

Sensitive, semi-quantitative Sensitive, quantitative High resolution In vivo or in vitro labeling No labeling necessary Bidifferential expression Small sample size Detects PTMs Sensitive, quantitative In vivo or in vitro labeling 4 stable isotope labels Detects PTMs Sensitive, quantitative Cell culture labeling Bidifferential expression Detects PTMs... [Pg.64]

The DNA-based sensors should have a rapid response time and should be quantitative, sensitive, suitable for automation, cost effective, disposable and solve analytical problems in a wide range of industrial contexts in order to be commercially viable. The developments attained so far by different transducing systems are going to be reviewed. [Pg.386]

Other OTM compounds that are indicated by preliminary studies to be efficient triplet sensitizers include ClRe(C0)2L (Table 12). In dichloromethane at room temperature these complexes are strongly luminescent and photo-inert (41). Under the same conditions, the emissions are quenched by oxygen, anthracene, and trans-stilbene. The trans cis isomerization of trans-stilbene is efficiently sensitized by several of these species. Quantitative sensitization experiments indicated that the luminescing excited states of ClRe(C0)3L are produced with 100 percent... [Pg.274]

How quantitatively sensitive is e to other forms of anisotropy that characterize the pair potential in real polar molecules ... [Pg.315]

Only exposed atoms on the surface, that is, the top monolayer of atoms, contributes to the signal in ISS. It is therefore the most surface sensitive of the surface analysis techniques. ISS is one technique that provides isotopic information on surface atoms. ISS can be used to determine all elements with an atomic number greater than that of the bombarding ion. The elemental and isotopic compositions of the surface can be determined both qualitatively and quantitatively. Sensitivity is about 1% of a monolayer for most elements. [Pg.907]

Mannans. — D-Galacto-D-mannan dyed with Remazol Brilliant Blue has been used in a simple assay procedure for D-mannanase. The procedure is quantitative, sensitive, and highly specific. [Pg.645]

Inhibitor constants (A j) or the concentration of inhibitor required for half-maximal inhibition under specified assay conditions ffo.s) provide an indication of the quantitative sensitivity of an enzyme. Such indicators of plant aspartate kinase sensitivity are consistently below 1.0 mM and in several instances are less than 100 fiM (Table III). Even though the effective concentration of regulatory metabolites in plant cells is difficult to estimate (Section III,C), the demonstrable inhibitory effects of comparatively low concentrations of lysine or threonine on aspartate kinase i/t vitro suggest that enzyme activity is likely to be regulated by these pathway products in vivo. [Pg.423]

Branney SW, Wolfe RE (1995) Quantitative sensitivity of ultrasound in detecting free intraperitoneal fluid. J Trauma 39 375-380... [Pg.157]

The simultaneous use of two or more detectors, whose outputs complement each other, can aid in compovmd identification by generating substance-characteristic detector response ratios. In some instances, the detectors are operated sequentially or, alternatively, the column eluate is split and passed separately to the individual detectors. The combination of a selective with a universal detector can provide information on both the whole sample and, at the same time, greater quantitative sensitivity on specific components. [Pg.1804]

We have already seen the effects of spectrometer resolution on quantitative sensitivity. This effect will, naturally, vary with the width of the band being used and the region of the spectrum in which we are working. This increased sensitivity can be applied to quantitative analysis because it permits use of more dilute solutions, which tends to promote better agreement with Beer s law in some solutions. In addition, the higher dispersion may permit use of wider slits, thereby effecting an increase in signal-to-noise ratio and an improvement in the readability of absorbance values. [Pg.86]

Campolongo, F., Saltelli, A., Cariboni, J. From screening to quantitative sensitivity analysis. A unified approach. Comput. Phys. Commun. 182, 978-988 (2011)... [Pg.134]

Wang W, Feng ZY, Jiang W, Zhan JH (2013) Electrospun porous CuO-Ag nanofibers for quantitative sensitive SERS detection. Crystengcomm 15 1339-1344... [Pg.352]


See other pages where Quantitation sensitivity is mentioned: [Pg.352]    [Pg.494]    [Pg.97]    [Pg.32]    [Pg.33]    [Pg.394]    [Pg.70]    [Pg.1057]    [Pg.127]    [Pg.417]    [Pg.368]    [Pg.321]    [Pg.560]    [Pg.328]    [Pg.172]    [Pg.77]    [Pg.160]    [Pg.161]    [Pg.145]    [Pg.985]    [Pg.68]    [Pg.83]    [Pg.100]    [Pg.5]    [Pg.420]    [Pg.172]   
See also in sourсe #XX -- [ Pg.470 ]