Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Pump Process Specification

It is usually process engineer s responsibility to specify a pump s process requirement on a pump data sheet. Providing the pump process specification is the first step to purchase a new pump or to rate an existing pump. The common practice is to select s new pump from a pump manufacturer s catalog by matching the pump s process requirement Veiy rarely, a new pump has to be designed from scratch. [Pg.16]

Prepare mechanical and process specifications for all equipment, tanks, pumps, compressors, separators, drying systems, refrigeration systems. This... [Pg.3]

An important specific feature of the present experiment is worth noting. The X-ray photons have energies that are several orders of magnitude larger than those of optical photons. The pump and probe processes thus evolve on different time scales and can be treated separately. It is convenient to start with the X-ray probing processes, and treat them by Maxwellian electrodynamics. The pumping processes are studied next using statistical mechanics of nonlinear optical processes. The electron number density n(r,t), supposed to be known in the first step, is actually calculated in this second step. [Pg.265]

Problems with insulin delivery in implanted pumps are difficult to correct. A change in Hoechst 21 pH-neutral semisynthetic insulin 400 U/ml in accordance with regulations of the European Pharmacopoeia (SEDA-20, 397) resulted in more frequent clogging when this insulin was used in the Minimed 2001 implantable pump (MIP 2001). From October 1995 to October 1996, 17 pumps were implanted (241). The refilling period was reduced from 90 to 30-45 days and the reservoirs were washed with insulin-free buffer before each refill. Backflow was seen in 13 pumps after a mean period of 7.2 months. Modification of the manufacturing process produced 21PH ETP insulin (human semisynthetic insulin, Genapol-stabilized) 400 U/ml, Hoechst, with improved stability since July 1997. All pumps were specifically cleaned before the new insulin was used for refill. The refill period was increased from 38 to 78 days. In 16 pumps, only one backflow was seen after 14 months. [Pg.408]

These unique phenotypes have provided invaluable information on the role of these pumps in specific tissues and species, and have improved our understanding of Ca2+ regulated processes in muscles, the heart and the skin in human and in mice. Although the understanding of the pathogenesis of these diseases is still incomplete, these recent advances hold the promise of improved knowledge on the disease processes and the identification of new targets for therapeutic interventions. [Pg.357]

To form the relatively undissociated water, 2 protons per electron pair, transported through complex IV, are removed from the mitochondrial matrix. An additional 2 protons per electron pair transported are extruded from the matrix by complex IV. The total number of protons lost by the mitochondrial matrix through the action of complexes I, III, and IV is thus 8-10 per electron pair, depending on the authority cited. The reason protons are extruded across the inner mitochondrial membrane is 2-fold complex IV apparently acts as a true proton pump with specific protein(s) of that complex acting as the transport particle(s). Complexes I and III, on the other hand, are associated with the so-called vectoral proton translocation process those enzymatic reactions that release protons (e.g., reoxidation of UQH2) take place at or near the intermembrane space surface on the inner mitochondrial membrane. This allows protons to be discharged into the intermembrane space rather than into the mitochondrial matrix. Overall, the pH differential between the cytosol and the mitochondrial matrix is about 1, or a 10-fold difference in [H+] (alkaline inside). [Pg.450]

There are different components that make up the extruder each with their specific important function. All components have to operate efficiently otherwise the extruder s operation is inefficient. A very important and essential parameter in the extruder is the plasticator s pumping process. It is the interaction between the rotating flights of the screw and the stationary barrel wall. For the plastic material to be conveyed, its friction must be low at the screw surface but high at the barrel wall. If this basic criterion is not met, the plastic will usually rotate with the screw and not move in the axial output direction. [Pg.231]

Now comes the key physical idea after an excited atom emits a photon, it drops down to a lower energy level and is no longer excited. Thus N decreases by the emission of photons. To capture this effect, we need to write an equation relating N to n. Suppose that in the absence of laser action, the pump keeps the number of excited atoms fixed at. Then the actual number of excited atoms will be reduced by the laser process. Specifically, we assume... [Pg.54]

The easiest method for creating many vibrational excitations is to use convenient pulsed visible or near-UV lasers to pump electronic transitions of molecules which undergo fast nonradiative processes such as internal conversion (e.g. porjDhyrin [64, 65] or near-IR dyes [66, 62, 68 and 62]), photoisomerization (e.g. stilbene [12] or photodissociation (e.g. Hgl2 [8]). Creating a specific vibrational excitation D in a controlled way requires more finesse. The easiest method is to use visible or near-UV pulses to resonantly pump a vibronic transition (e.g. [Pg.3038]


See other pages where Pump Process Specification is mentioned: [Pg.16]    [Pg.16]    [Pg.168]    [Pg.419]    [Pg.509]    [Pg.362]    [Pg.102]    [Pg.48]    [Pg.337]    [Pg.307]    [Pg.909]    [Pg.17]    [Pg.1774]    [Pg.430]    [Pg.435]    [Pg.310]    [Pg.433]    [Pg.28]    [Pg.157]    [Pg.166]    [Pg.909]    [Pg.486]    [Pg.838]    [Pg.248]    [Pg.620]    [Pg.10]    [Pg.37]    [Pg.527]    [Pg.1]    [Pg.319]    [Pg.147]    [Pg.747]    [Pg.9]    [Pg.50]    [Pg.43]    [Pg.49]    [Pg.227]    [Pg.241]   


SEARCH



Pump specification

Pumping process

© 2024 chempedia.info