Principle and operation modes

It must be made clear that WSL has only used olfactometers constructed on its own premises and calibrated by WSL staff one such instrument is the WSL Transportable model. (It is emphasised that this olfactometer is not the same as the commercially-available Portable model.) The WSL Transportable olfactometer and its operation have been described in detail previously (1) and only its main features need be reviewed here. From time to time, certain applications have required a special re-design of the olfactometer, e.g. to measure very weak odours, but the basic principles and the mode of operation have remained unchanged for some years. The main features of the standard WSL Transportable olfactometer are as follows ... [Pg.70]

Various combinations of bioreactors and operation mode have been used for the production of mAbs in several systems of expression, as shown in Chapter 9. All cells utilized for the production of mAbs grow in suspension. Those that did not initially have this capacity have been adapted (as is the case for CHO and BHK) (Butler, 2005). This results in a large number of options for production systems. Cells with this characteristic are easily cultivated in stirred-tank reactors, which have been scaled up to a volume of 10 000 L (Chu and Robinson, 2001 Kretzmer, 2002). This kind of bioreactor provides excellent homogeneity, facility for the implementation of control techniques, and the principles of scaling up are relatively well known. Other kinds of bioreactors for the production of mAbs are also available, such as air-lift, with volumes up to 1000 L, and also fixed-bed bioreactors (Moro et al., 1994 Irving et al., 1996 Kretzmer, 2002). [Pg.429]

In the first chapter, we introduce the concept of methanol economy, as an alternative to the most popular but still elusive hydrogen economy, and we also provide a brief historical description of fundamental research on electrochemical oxidation of methanol and the development of the first alkaline direct methanol fuel cells more than 60 years ago. The operating principles of PEM and alkaline direct alcohol fuel cells are analyzed, as well as their components, configuration, and operation modes, with a final remark on the state of the art of the technology. [Pg.377]

Howland, Rebecca, and Lisa Benatar. A Practical Guide to Scanning Probe Microscopy. ThermoMi-croscopes. March 2000. Web. Accessed September, 2011. This introductory guide to scanning probe microscopy describes several techniques and operating modes of the devices, as well as their structure and principles of operation, and discusses the occurrence of ims e artifacts in their use. [Pg.1645]

Only several commonly used SECM methods and operation modes are briefly described in the following sections. Different methods are listed and available in commercially available SECMs. The operational principles and practical procedures for each technique are described in the other chapters. [Pg.19]

Figure Bl.19.1. Principle of operation of a scanning tiimrelling microscope. The x- andj -piezodrives scan the tip across the surface. In one possible mode of operation, the current from the tip is fed into a feedback loop that controls the voltage to die z-piezo, to maintam constant current. The Ime labelled z-displacement shows the tip reacting both to morphological and chemical (i.e. electronic) inliomogeneities. (Taken from [213].)... Figure Bl.19.1. Principle of operation of a scanning tiimrelling microscope. The x- andj -piezodrives scan the tip across the surface. In one possible mode of operation, the current from the tip is fed into a feedback loop that controls the voltage to die z-piezo, to maintam constant current. The Ime labelled z-displacement shows the tip reacting both to morphological and chemical (i.e. electronic) inliomogeneities. (Taken from [213].)...
Scrubber Ttfpes and Performance The diversity of particulate scrubber designs is so great as to defy any detailed and selhconsistent system of classification based on configuration or principle of operation. However, it is convenient to cliaracterize scrubbers loosely according to prominent constructional features, even though the modes of operation of different devices in a group may vary widely. [Pg.1591]

Electronic ratio controller. In this type of controller, a proportion of both gas and air is diverted through a bypass in which a thermistor sensor measures the flow. The air and gas flows can be compared and the ratio calculated and displayed. A ratio control valve in the air or gas supply, depending on whether the mode of operation is gas- or air-led, will automatically restore a deviation from the pre-set ratio. The electronic controller maintains ratio over a 19 1 turndown. The principle of operation is based on mass flow, so that it can be used with preheated air in recuperative systems. [Pg.278]

In this chapter, we present the principles of conventional Mossbauer spectrometers with radioactive isotopes as the light source Mossbauer experiments with synchrotron radiation are discussed in Chap. 9 including technical principles. Since complete spectrometers, suitable for virtually all the common isotopes, have been commercially available for many years, we refrain from presenting technical details like electronic circuits. We are concerned here with the functional components of a spectrometer, their interaction and synchronization, the different operation modes and proper tuning of the instrument. We discuss the properties of radioactive y-sources to understand the requirements of an efficient y-counting system, and finally we deal with sample preparation and the optimization of Mossbauer absorbers. For further reading on spectrometers and their technical details, we refer to the review articles [1-3]. [Pg.25]

Principles and Characteristics Many of the planar chromatography methods rely on fluorescence detection to achieve the required identification limits exploitation of sensitive and selective derivatisation reactions is of considerable importance. Most TLC scanning densitometers can be operated in the fluorescence mode and are able to record in situ excitation spectra of TLC... [Pg.531]

Thus, selective product removal between stages as described has increased the rate of production from 0.043, part (a), to 0.0565 mol h-1, part (b), and the conversion from 0.689 to 0.905. Of course, this has been achieved at the expense of whatever additional equipment is required for the selective product removal. Whether this operating mode is feasible in a particular situation requires further analysis, including optimization with respect to the extent of selective removal of products and a cost analysis. This example is for illustration of the operating mode in principle. [Pg.426]

The principle of operation of this sensor is based on the fact that, as the fundamental optical mode travels through the MNF, its shape is modified depending on the index contrast between the solution in the channel and the polymer. Consequently, the change of the fundamental mode results in variation of the MNF... [Pg.350]

In principle, a further inexpensive method is to work at constant cell voltage. But here the potentials of the working and of the counter electrode, and all voltage drops of the electrolytes and of the cell separator are included (see Fig. 2). Thus, in most cases, clearly defined conditions at the working electrode cannot be adjusted using this operation mode (nevertheless, because of its uncomplicated realization, it is applied in most technical electrolyses to achieve approximately the desired cell current). [Pg.37]

To implement the principles of the basic system and extended basic systems into experimental systems operated in several operational modes. The analytical models developed in this study will be used to design experimental operational conditions and to investigate the results obtained. [Pg.28]

However, the situation is not always clear-cut and more than one binding principle can operate, which means that many SOs and CSPs have mixed-mode interaction sites. [Pg.210]


See other pages where Principle and operation modes is mentioned: [Pg.420]    [Pg.193]    [Pg.193]    [Pg.163]    [Pg.165]    [Pg.420]    [Pg.193]    [Pg.193]    [Pg.163]    [Pg.165]    [Pg.249]    [Pg.284]    [Pg.241]    [Pg.165]    [Pg.363]    [Pg.50]    [Pg.356]    [Pg.399]    [Pg.417]    [Pg.994]    [Pg.285]    [Pg.290]    [Pg.362]    [Pg.393]    [Pg.490]    [Pg.496]    [Pg.275]    [Pg.352]    [Pg.357]    [Pg.141]    [Pg.156]    [Pg.347]    [Pg.240]    [Pg.195]    [Pg.113]    [Pg.202]   
See also in sourсe #XX -- [ Pg.165 , Pg.166 , Pg.167 , Pg.168 , Pg.169 , Pg.170 , Pg.171 ]