Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Primary monitoring

However, rolls are highly prone to loads induced by the process. In most cases, rolls carry some form of product or a mechanism that, in turn, carries a product. For example, a simple conveyor has rolls that carry a belt, which carries product from one location to another. The primary monitoring parameters for process rolls include bearings, load distribution, and misalignment. [Pg.711]

Figure 8. Overall system description given by the primary monitor... Figure 8. Overall system description given by the primary monitor...
The final obvious action will be to print "EXECUTE — Y or N ". If an "N" is entered the command decoder will terminate itself and the primary monitor will be started. A response of "Y" will cause the acquisition of spectral data to begin. [Pg.149]

Examination of Spectral Data. Control of the System will return to the primary monitor when data acquisition has been concluded. At this point if a 2 is given in response to the query "MODE , then the secondary monitor will be started so that it can oversee the use of the x-y point-plot-display and a Calcomp plotter. [Pg.150]

Transfer of Data From Disk to Magnetic Tape. Transfer of the spectral data from disk to magnetic tape is accomplished by responding to the primary monitor s que with a 5. Each time this mode of operation is entered two files will be written to magtape. The first file will contain one record of five hundred twelve bytes, where a byte is six bits. The information written will be the sample name and comments which were given to the data acquisition command decoder. The files are terminated with an end of file mark. [Pg.158]

The normal tendency of the rotors and helical timing gears is to generate axial shaft movement, or thrusting. However, the extremely tight clearances between the male and female rotors do not tolerate any excessive axial movement, and therefore, axial movement should be a primary monitoring parameter. Axial measurements are needed from both rotor assemblies. If there is any increase in the vibration amplitude of these measurements, it is highly probable that the compressor will fail. [Pg.166]

The interest in vesicles as models for cell biomembranes has led to much work on the interactions within and between lipid layers. The primary contributions to vesicle stability and curvature include those familiar to us already, the electrostatic interactions between charged head groups (Chapter V) and the van der Waals interaction between layers (Chapter VI). An additional force due to thermal fluctuations in membranes produces a steric repulsion between membranes known as the Helfrich or undulation interaction. This force has been quantified by Sackmann and co-workers using reflection interference contrast microscopy to monitor vesicles weakly adhering to a solid substrate [78]. Membrane fluctuation forces may influence the interactions between proteins embedded in them [79]. Finally, in balance with these forces, bending elasticity helps determine shape transitions [80], interactions between inclusions [81], aggregation of membrane junctions [82], and unbinding of pinched membranes [83]. Specific interactions between membrane embedded receptors add an additional complication to biomembrane behavior. These have been stud-... [Pg.549]

With M = He, experimeuts were carried out between 255 K aud 273 K with a few millibar NO2 at total pressures between 300 mbar aud 200 bar. Temperature jumps on the order of 1 K were effected by pulsed irradiation (< 1 pS) with a CO2 laser at 9.2- 9.6pm aud with SiF or perfluorocyclobutaue as primary IR absorbers (< 1 mbar). Under these conditions, the dissociation of N2O4 occurs within the irradiated volume on a time scale of a few hundred microseconds. NO2 aud N2O4 were monitored simultaneously by recording the time-dependent UV absorption signal at 420 run aud 253 run, respectively. The recombination rate constant can be obtained from the effective first-order relaxation time, A derivation analogous to (equation (B2.5.9). equation (B2.5.10). equation (B2.5.11) and equation (B2.5.12)) yield... [Pg.2120]

Schematic diagram of a purge-and-trap system. Anaiyte is coiiected in the primary adsorption trap. The secondary adsorption trap is monitored for evidence of breakthrough. Schematic diagram of a purge-and-trap system. Anaiyte is coiiected in the primary adsorption trap. The secondary adsorption trap is monitored for evidence of breakthrough.
Samples of analyte are dissolved in a suitable solvent and placed on the IR card. After the solvent evaporates, the sample s spectrum is obtained. Because the thickness of the PE or PTEE film is not uniform, the primary use for IR cards has been for qualitative analysis. Zhao and Malinowski showed how a quantitative analysis for polystyrene could be performed by adding an internal standard of KSCN to the sample. Polystyrene was monitored at 1494 cm- and KSCN at 2064 cm-. Standard solutions were prepared by placing weighed portions of polystyrene in a 10-mL volumetric flask and diluting to volume with a solution of 10 g/L KSCN in... [Pg.453]

The lines of primary interest ia an xps spectmm ate those reflecting photoelectrons from cote electron energy levels of the surface atoms. These ate labeled ia Figure 8 for the Ag 3, 3p, and 3t7 electrons. The sensitivity of xps toward certain elements, and hence the surface sensitivity attainable for these elements, is dependent upon intrinsic properties of the photoelectron lines observed. The parameter governing the relative iatensities of these cote level peaks is the photoionization cross-section, (. This parameter describes the relative efficiency of the photoionization process for each cote electron as a function of element atomic number. Obviously, the photoionization efficiency is not the same for electrons from the same cote level of all elements. This difference results ia variable surface sensitivity for elements even though the same cote level electrons may be monitored. [Pg.275]

The term aquifer is used to denote an extensive region of saturated material. There are many types of aquifers. The primary distinction between types involves the boundaries that define the aquifer. An unconfined aquifer, also known as a phraetic or water table aquifer, is assumed to have an upper boundary of saturated soil at a pressure of zero gauge, or atmospheric pressure. A confined aquifer has a low permeabiUty upper boundary that maintains the interstitial water within the aquifer at pressures greater than atmospheric. For both types of aquifers, the lower boundary is frequendy a low permeabihty soil or rock formation. Further distinctions exist. An artesian aquifer is a confined aquifer for which the interstitial water pressure is sufficient to allow the aquifer water entering the monitoring well to rise above the local ground surface. Figure 1 identifies the primary types of aquifers. [Pg.401]

Immunosensors promise to become principal players ia chemical, diagnostic, and environmental analyses by the latter 1990s. Given the practical limits of immunosensors (low ppb or ng/mL to mid-pptr or pg/mL) and their portabiUty, the primary appHcation is expected to be as rapid screening devices ia noncentralized clinical laboratories, ia iatensive care faciUties, and as bedside monitors, ia physicians offices, and ia environmental and iadustrial settings (49—52). Industrial appHcations for immunosensors will also include use as the basis for automated on-line or flow-injection analysis systems to analyze and control pharmaceutical, food, and chemical processing lines (53). Immunosensors are not expected to replace laboratory-based immunoassays, but to open up new appHcations for immunoassay-based technology. [Pg.30]

Tank bottom slope is important because sediment, water, and heavy phases settle at the bottom. Corrosion is usually the most severe at the bottom, and the design of the bottom can have a significant effect on the life of the tank. In addition, if the Hquid stock is changed, it is usually desirable to remove as much as the previous stock as possible. Therefore, designs that allow for the removal of water or stock and the ease of tank cleaning have evolved. In addition, specialized tank bottoms have resulted from the need to monitor and detect leaks. Tank bottoms in contact with the soil or foundations are one of the primary sources of leaks from aboveground tanks. [Pg.315]

The first human kidney and bone marrow transplants using cyclosporine were reported in 1978. Oral or intravenous cyclosporine is an immunosuppressant for transplantation of these and other organs and investigations are underway for its possible use in a variety of autoimmune diseases including rheumatoid arthritis, severe psoriasis, and Crohn s disease. Dose-dependent nephrotoxicity (261—264) remains the primary limitation of the dmg and necessitates close monitoring of patients, including measurement of dmg levels in blood. Cyclosporine research has been reviewed (265—274). [Pg.159]

One of the primary concerns of all power plants is to ensure high electricity production and reduce hazardous and waste substances. In that way green electricity could be produced. It is essential to monitor the presence and movement of impurities in various measuring sites in air, water and soil [1]. The presence of hazardous species in these eco-systems, even at low-mg/1 levels, has negative effects for nature and human beings [2, 3]. [Pg.229]

These are protection CTs lor special applications such as biased differential protection, restricted ground fault protection and distance protection schemes, where it is not possible to easily identify the elass of accuracy, the accuracy limit factor and the rated burden of the CTs and where a full primary fault current is required to be transformed to the secondary without saturation, to accurately monitor the level of fault and/or unbalance. The type of application tind the relay being used determine the knee point voltage. The knee point voltage and the excitation current of the CTs now form the basic design parameters for such CTs. They are classified as class PS CTs and can be identified by the following characteristics ... [Pg.479]


See other pages where Primary monitoring is mentioned: [Pg.14]    [Pg.238]    [Pg.238]    [Pg.387]    [Pg.317]    [Pg.125]    [Pg.45]    [Pg.14]    [Pg.238]    [Pg.238]    [Pg.387]    [Pg.317]    [Pg.125]    [Pg.45]    [Pg.295]    [Pg.322]    [Pg.200]    [Pg.279]    [Pg.378]    [Pg.374]    [Pg.257]    [Pg.403]    [Pg.511]    [Pg.18]    [Pg.413]    [Pg.234]    [Pg.153]    [Pg.33]    [Pg.7]    [Pg.83]    [Pg.245]    [Pg.421]    [Pg.151]    [Pg.190]    [Pg.379]    [Pg.2231]    [Pg.111]    [Pg.768]   
See also in sourсe #XX -- [ Pg.119 ]




SEARCH



© 2024 chempedia.info