Rooms pressure control

Total enclosure may be in the form of a room with grilles to facilitate air flow this functions as a hood and operates under a slight negative pressure with controls located externally. Entry is restricted and usually entails use of comprehensive personal protective equipment. Ancillary requirements may include air filters/scmbbers, atmospheric monitoring, decontamination procedures and a permit-to-work system (see page 417). [Pg.406]

Total enclosure may be in the form of a room with grilles to facilitate air flow this functions as a hood and operates under a slight negative pressure with controls located... [Pg.274]

Facilities validation is a critical process in a pharmaceutical industry and the types of pharmaceutical forms produced must be considered. Facilities that produce different pharmaceutical forms have different specific requirements and different critical parameters based on risk assessment. All facilities must have an adequate flow of people, raw materials, bulk products, and finished products. These flows must be created in order to avoid cross-contamination. Additionally, pressurized rooms and adequate SOPs should be supplied to minimize the risk of cross-contamination. Controlled air temperature and humidity are also required and should be validated to ensure adequate stability of the product. [Pg.837]

Fig. 3 Schematic diagram of the gas-handling system and the environment-controlled AFM chamber. The alcohol partial pressure is controlled by varying the ratio of dry Ar and alcohol saturated Ar gas flowrates. The alcohol saturated Ar gas stream is generated by flowing Ar through a heated bubbler followed by a condensor held at room temperature. Fig. 3 Schematic diagram of the gas-handling system and the environment-controlled AFM chamber. The alcohol partial pressure is controlled by varying the ratio of dry Ar and alcohol saturated Ar gas flowrates. The alcohol saturated Ar gas stream is generated by flowing Ar through a heated bubbler followed by a condensor held at room temperature.
A series of two-pha.se detonations were performed using liquid hexane cis the fuel and gaseous oxygen as the oxidizer. The experiments were performed at atmospheric pressure and room temperature. The equivalence ratio and fuel pressure (which controls mean droplet diameter) were varied, and the effect on detonation velocity was observed. The results of this series of experiments are collected in Fig. 1.5 and shown alongside gcis-phase CJ velocity predictions. [Pg.279]

The charge, having known proportions of CaC03 and Ca(OH)2, was mixed with liquid water and then heated to above the liquidus temperature. The system pressure was controlled by venting excess steam from valve A. After holding the system at the desired temperature and pressure for about 20 min., the charge was cooled at 5°F./min. to just below the eutectic temperature, then rapidly to room temperature. [Pg.160]

Room controllers are basically maintenance-free devices as long as they receive accurate input signals, have clean uninterrupted power or supply air, and are not abused. Once installed, they usually require little calibration unless they have been tampered with or application requirements change. It is still a good idea to check the operation of a controller by reading the output pressure or voltage for a known condition in the space. [Pg.504]

The letdown flow outside containment isolation valve is a normally closed, fail closed, air-operated globe valve that isolates letdown to the liquid radwaste system. This valve automatically opens and closes on a plant control system signal from the pressuriser level control system or a containment isolation signal from the protection and safety monitoring system. Ibis valve operates in the same fashion as the letdown flow inside containment isolation valve. The letdown flow outside containment isolation valve eloses more quickly than inside containment letdown flow isolation valve to limit seat wear of inside containment isolation valve. This valve operator has a flow restricting orifice in the air line, so it opens more slowly than inside containment letdown flow isolation valve. In addition, during brief periods of shutdown, when the reactor coolant system is water solid, this valve throttles to maintain the reactor coolant system pressure. Manual control is also provided in the main control room and at the remote shutdown workstation. [Pg.216]

If ac power is unavailable for more than 10 minutes, pressurizer pressure falls below the low setpoint, or if "high-high" particulate or iodine radioactivity is detected in the main control room supply air duct, the protection and safety monitoring system automatically isolates the main control room from the normal main control room/control support area HVAC subsystem by closing the supply, return, and toilet exhaust isolation valves. Main control room habitability is maintained by the main control room emergency habitability system, which is discussed in Section 6.4.4 of this PCSR. [Pg.285]

In a 500 ml. three-necked flask, equipped with a mechanical stirrer, thermometer and dropping funnel, place 300 ml. of 88-90 per cent, formic acid and add 70 ml. of 30 per cent, hydrogen peroxide. Then introduce slowly 41 g. (51 ml.) of freshly distilled cyclohexene (Section 111,12) over a period of 20-30 minutes maintain the temperature of the reaction mixture between 40° and 45° by cooling with an ice bath and controlling the rate of addition. Keep the reaction mixture at 40° for 1 hour after all the cyclohexene has been added and then allow to stand overnight at room temperature. Remove most of the formic acid and water by distillation from a water bath under reduced pressure. Add an ice-cold solution of 40 g. of sodium hydroxide in 75 ml. of water in small portions to the residual mixture of the diol and its formate take care that the tempera... [Pg.894]


See other pages where Rooms pressure control is mentioned: [Pg.34]    [Pg.260]    [Pg.60]    [Pg.641]    [Pg.418]    [Pg.1452]    [Pg.2021]    [Pg.59]    [Pg.116]    [Pg.301]    [Pg.1124]    [Pg.1137]    [Pg.1149]    [Pg.542]    [Pg.545]    [Pg.429]    [Pg.284]    [Pg.285]    [Pg.285]    [Pg.285]    [Pg.46]    [Pg.260]    [Pg.44]    [Pg.140]    [Pg.182]    [Pg.418]    [Pg.1004]    [Pg.232]    [Pg.50]    [Pg.370]    [Pg.82]    [Pg.498]    [Pg.298]    [Pg.177]    [Pg.54]    [Pg.90]    [Pg.96]    [Pg.97]   
See also in sourсe #XX -- [ Pg.594 , Pg.595 , Pg.596 ]




SEARCH



Control rooms

Pressure control

Pressure, room

Room Pressure Control Systems