Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Polystyrenes analysis

Methylene Chloride Fractionation of Cross-Coupled 1. 2 and 7. A sample of the block polymer (above 0.50g) was dissolved in 10 mL of methylene chloride. The soluton was stored at 2 C for 2 days. A polymer methylene chloride complex precipitate formed which was removed by filtration at 2aC. The precipitate was then heated at 50 to drive off the methylene chloride. The dried polymer weighed 0.43g and contained (based on IR analysis) 58% by weight of poly(phenylene oxide) and 42% by weight of polystyrene. Analysis of the filtrate after evaporation of the methylene chloride established the presence of a residue containing 17% polyphenylene oxide and 83% polystyrene. On the basis of these results, at least 72% of the initial polystyrene charged to the reaotion medium was calculated as having been incorporated into an acyl-coupled polyphenylene oxide-polystyrene block polymer. [Pg.196]

PL 10 pM gel mixed B 500-10 Polymer MW distributions Polystyrene standard separation, polystyrene analysis, polymethyl methacrylate analysis polyethylene terephthalate, polymide, polyvinylchloride, pyrrolidone, fluoropolymei butyl rubber, polyethylene, copolymers... [Pg.270]

Samples of analyte are dissolved in a suitable solvent and placed on the IR card. After the solvent evaporates, the sample s spectrum is obtained. Because the thickness of the PE or PTEE film is not uniform, the primary use for IR cards has been for qualitative analysis. Zhao and Malinowski showed how a quantitative analysis for polystyrene could be performed by adding an internal standard of KSCN to the sample. Polystyrene was monitored at 1494 cm- and KSCN at 2064 cm-. Standard solutions were prepared by placing weighed portions of polystyrene in a 10-mL volumetric flask and diluting to volume with a solution of 10 g/L KSCN in... [Pg.453]

Principal component analysis has been used in combination with spectroscopy in other types of multicomponent analyses. For example, compatible and incompatible blends of polyphenzlene oxides and polystyrene were distinguished using Fourier-transform-infrared spectra (59). Raman spectra of sulfuric acid/water mixtures were used in conjunction with principal component analysis to identify different ions, compositions, and hydrates (60). The identity and number of species present in binary and tertiary mixtures of polycycHc aromatic hydrocarbons were deterrnined using fluorescence spectra (61). [Pg.429]

For quantitative analysis of solid supported thiol residues on free macroporous or PEG grafts, Ellman s reagent has been used [5,5 -dithio-hfr-(2-nitrobenzoic acid]. However only qualitative information can be gained using lightly crosslinked polystyrene resins [Badyal et al. Tetrahedron Lett 42 8531 2007]. [Pg.76]

Figure 1 shows a positive static SIMS spectrum (obtained using a quadrupole) for polyethylene over the mass range 0—200 amu. The data are plotted as secondary ion intensity on a linear y-axis as a function of their chaige-to-mass ratios (amu). This spectrum can be compared to a similar analysis from polystyrene seen in Figure 2. One can note easily the differences in fragmentation patterns between the... Figure 1 shows a positive static SIMS spectrum (obtained using a quadrupole) for polyethylene over the mass range 0—200 amu. The data are plotted as secondary ion intensity on a linear y-axis as a function of their chaige-to-mass ratios (amu). This spectrum can be compared to a similar analysis from polystyrene seen in Figure 2. One can note easily the differences in fragmentation patterns between the...
Small particle size resins provide higher resolution, as demonstrated in Fig. 4.41. Low molecular weight polystyrene standards are better separated on a GIOOOHxl column packed with 5 /u,m resin than a GlOOOHg column packed with 10 /Ltm resin when compared in the same analysis time. Therefore, smaller particle size resins generally attain a better required resolution in a shorter time. In this context, SuperH columns are best, and Hhr and Hxl columns are second best. Most analyses have been carried out on these three series of H type columns. However, the performance of columns packed with smaller particle size resins is susceptible to some experimental conditions such as the sample concentration of solution, injection volume, and detector cell volume. They must be kept as low as possible to obtain the maximum resolution. Chain scissions of polymer molecules are also easier to occur in columns packed with smaller particle size resins. The flow rate should be kept low in order to prevent this problem, particularly in the analyses of high molecular weight polymers. [Pg.143]

FIGURE 10.6 Analysis of sulfonated polystyrenes on SynChropak GPC 100. Column 2S0 X 4.6 mm i.d. Mobile phase 0.1 /H sodium sulfate. Flow rate 0.2S ml/min. (From MICRA Scientific, Inc., with permission.)... [Pg.312]

For organic SEC separations the use of polystyrene/divinylbenzene (PS/ DVB) particles is almost universal throughout the industry. Polymer Laboratories PS/DVB material, PLgel, which is produced in a series of individual pore sizes, formed the basis for the original product line of SEC columns. Developments in the refinement of particle sizing introduced the benefits of smaller particle size and more efficient columns, which significantly reduced SEC analysis time through a reduction in the number of columns required for... [Pg.349]

Gel permeation ehromatography (GPC)/normal-phase HPLC was used by Brown-Thomas et al. (35) to determine fat-soluble vitamins in standard referenee material (SRM) samples of a fortified eoeonut oil (SRM 1563) and a eod liver oil (SRM 1588). The on-line GPC/normal-phase proeedure eliminated the long and laborious extraetion proeedure of isolating vitamins from the oil matrix. In faet, the GPC step permits the elimination of the lipid materials prior to the HPLC analysis. The HPLC eolumns used for the vitamin determinations were a 10 p.m polystyrene/divinylbenzene gel eolumn and a semipreparative aminoeyano eolumn, with hexane, methylene ehloride and methyl tert-butyl ether being employed as solvent. [Pg.232]

The formation of these polar groups contributes increased adhesion. Observation of disappearing vinyl groups in the silane coupling agent and of the formation of polystyrene in the silica by FTIR analysis (Fig. 15) have confirmed the occurrence of a reaction between the polymer and the silane coupling agent [77]. [Pg.827]

Figures 12-12 and 12-13 document that trap-free SCL-conduction can, in fact, also be observed in the case of electron transport. Data in Figure 12-12 were obtained for a single layer of polystyrene with a CF -substituted vinylquateiphenyl chain copolymer, sandwiched between an ITO anode and a calcium cathode and given that oxidation and reduction potentials of the material majority curriers can only be electrons. Data analysis in terms of Eq. (12.5) yields an electron mobility of 8xl0 ycm2 V 1 s . The rather low value is due to the dilution of the charge carrying moiety. The obvious reason why in this case no trap-limited SCL conduction is observed is that the ClVquatciphenyl. substituent is not susceptible to chemical oxidation. Figures 12-12 and 12-13 document that trap-free SCL-conduction can, in fact, also be observed in the case of electron transport. Data in Figure 12-12 were obtained for a single layer of polystyrene with a CF -substituted vinylquateiphenyl chain copolymer, sandwiched between an ITO anode and a calcium cathode and given that oxidation and reduction potentials of the material majority curriers can only be electrons. Data analysis in terms of Eq. (12.5) yields an electron mobility of 8xl0 ycm2 V 1 s . The rather low value is due to the dilution of the charge carrying moiety. The obvious reason why in this case no trap-limited SCL conduction is observed is that the ClVquatciphenyl. substituent is not susceptible to chemical oxidation.
Dynamic differential thermal analysis is used to measure the phase transitions of the polymer. IR is used to determine the degree of unsaturation in the polymer. Monitoring of the purity and raw is done commercially using gas phase chromatography for fractionization and R1 with UV absorption at 260 nanometers for polystyrene identification and measurement Polystyrene is one of the most widely used plastics because of fabrication ease and the wide spectrum of properties possible. Industries using styrene-based plastics are packaging, appliance, construction, automotive, radio and television, furniture, toy, houseware and baggage. Styrene is also used by the military as a binder in expls and rocket propints... [Pg.327]

Instrumental methods of peroxide analysis feature polarography, which is used to detn hydroperoxides, peroxyesters and diacyl peroxides as well as dicyclohexyl peroxydicarbonate in polystyrene. Other techniques include infrared (800 to 900cm 1) chemiluminescent analysis for kinetic studies, and chromatography for the identification and separation of peroxides in complex mixts (Refs 5,6, 7,14,15,16,17, 20 21)... [Pg.681]

Fig. 5. Hydrogen depth profile of a deuterated polystyrene PS(D) film deposited on a protonated polystyrene PS(H) film on top of a silicon wafer as obtained by l5N-nuclear reaction analysis ( 5N-NRA). The small hydrogen peak at the surface is due to contamination (probably water) of the surface. The sharp interface between PS(D) and PS(H) is smeared by the experimental resolution (approx. 10 nm at a depth of 80 nm) [57], The solid line is a guide for the eye... Fig. 5. Hydrogen depth profile of a deuterated polystyrene PS(D) film deposited on a protonated polystyrene PS(H) film on top of a silicon wafer as obtained by l5N-nuclear reaction analysis ( 5N-NRA). The small hydrogen peak at the surface is due to contamination (probably water) of the surface. The sharp interface between PS(D) and PS(H) is smeared by the experimental resolution (approx. 10 nm at a depth of 80 nm) [57], The solid line is a guide for the eye...
Under argon, a mixture of 145 (0.046 mmol), 132 (0.046 mmol), Pd(PPli3)4 (0.2 (junol), Cul (0.2 [miol), and diisopropylamine (0.015 mmol) in THF (4 mL) was stirred in the dark at 50°C for 2 days. Ethynylbenzene (0.92 mmol) was then added and stirred at 50°C overnight. After concentration, die residue was dissolved in CHCI3 and filtered. The filtrate was subjected to preparative SEC with CHCI3 as eluent in order to remove catalyst residues and unreacted starting materials. Polymer 42 was obtained as a yellow solid in 85% yield. SEC analysis (THF, polystyrene standards) Mw = 280,000 (PDI = 6.5). [Pg.522]


See other pages where Polystyrenes analysis is mentioned: [Pg.378]    [Pg.481]    [Pg.9]    [Pg.125]    [Pg.319]    [Pg.63]    [Pg.479]    [Pg.378]    [Pg.481]    [Pg.9]    [Pg.125]    [Pg.319]    [Pg.63]    [Pg.479]    [Pg.370]    [Pg.198]    [Pg.549]    [Pg.148]    [Pg.151]    [Pg.11]    [Pg.258]    [Pg.498]    [Pg.589]    [Pg.149]    [Pg.371]    [Pg.19]    [Pg.292]    [Pg.308]    [Pg.548]    [Pg.270]    [Pg.309]    [Pg.871]    [Pg.114]    [Pg.469]    [Pg.43]    [Pg.358]    [Pg.361]    [Pg.370]    [Pg.371]    [Pg.385]   
See also in sourсe #XX -- [ Pg.130 , Pg.134 ]




SEARCH



© 2024 chempedia.info