Column Efficiency. Under ideal conditions the profile of a solute band resembles that given by a Gaussian distribution curve (Fig. 11.1). The efficiency of a chromatographic system is expressed by the effective plate number defined from the chromatogram of a single band. [Pg.1105]

Band Asymmetry. The peak asymmetry factor AF is often defined as the ratio of peak half-widths at 10% of peak height, that is, the ratio b/a, as shown in Fig. 11.2. When the asymmetry ratio lies outside the range 0.95-1.15 for a peak of k =2, the effective plate number should be calculated from the expression... [Pg.1105]

Normal Stress (Weissenberg Effect). Many viscoelastic fluids flow in a direction normal (perpendicular) to the direction of shear stress in steady-state shear (21,90). Examples of the effect include flour dough climbing up a beater, polymer solutions climbing up the inner cylinder in a concentric cylinder viscometer, and paints forcing apart the cone and plate of a cone—plate viscometer. The normal stress effect has been put to practical use in certain screwless extmders designed in a cone—plate or plate—plate configuration, where the polymer enters at the periphery and exits at the axis. [Pg.178]

Entrainment Entrainment in a plate column is that liquid which is carried with the vapor from a plate to the plate above. It is detrimental in that the effective plate efficiency is lowered because hquid from a plate of lower volatility is carried to a plate of higher volatility, thereby diluting distillation or absorption effects. Entrainment is also detrimental when nonvolatile impurities are carried upward to contaminate the overhead product from the column. [Pg.1374]

Plate Towers Plate (tray) towers are countercurrent gas-atomized spray scrubbers using one or more plates for gas-liquid contacting. They are essentially the same as, if not identical to, the devices used for gas absorption and are frequently employed in apphcations in which gases are to be absorbed simultaneously with the removal of dust. Except possibly in cases in which condensation effects are involved, countercurrent operation is not significantly beneficial in dust collection. [Pg.1594]

The idea of the effective plate number was introduced and employed by Purnell [4], Desty [5] and others in the late 1950s. Its conception was evoked as a direct result of the introduction of the capillary column or open tubular column. Even in 1960, the open tubular column could be constructed to produce efficiencies of up to a million theoretical plates [6]. However, it became immediately apparent that these high efficiencies were only obtained for solutes eluted at very low (k ) values and, consequently, very close to the column dead volume. More importantly, on the basis of the performance realized from packed columns, the high efficiencies did not... [Pg.187]

Equation (18) displays the relationship between the column efficiency defined in theoretical plates and the column efficiency given in effective plates. It is clear that the number of effective plates in a column is not aii arbitrary measure of the column performance, but is directly related to the column efficiency as derived from the plate theory. Equation (18) clearly demonstrates that, as the capacity ratio (k ) becomes large, (n) and (Ne) will converge to the same value. [Pg.189]

As a secondary consideration, the chromatographer may also need to know the minimum value of the separation ratio (a) for a solute pair that can be resolved by a particular column. The minimum value of (a) has also been suggested [8] as an alternative parameter that can be used to compare the performance of different columns. There is, however, a disadvantage to this type of criteria, due to the fact that the value of (a) becomes less as the resolving power of the column becomes greater. Nevertheless, a knowledge of the minimum value of (cxa/b) can be important in practice, and it is of interest to determine how the minimum value of (aA/B) is related to the effective plate number. [Pg.190]

It is seen that the chromatographer can arrive at the minimum (aA/e) value for a pair of solutes that the column can resolve directly, from either the resolution, as defined by Giddings, or from a simple function of the number of effective plates. However, again it must be emphasized that this will not be a unique value for any column, as it will also depend on the (k ) of the eluted solute. [Pg.190]

T. A. Berger, Separation of a gasoline on an open tubular column with 1.3 million effective plates , Chromatographia 42 63 (1996). [Pg.14]

The quantitative assessment of the degree of crystallite orientation by x-ray examination is not free of ambiguity. From a comparative analysis [23] in which results obtained from the consideration of (105) and from three different variations of equatorial reflection were compared, the conclusion was that the first procedure can lead to underrated results, i.e., to the underestimation of the orientation. However, it can be assumed that this does not result from an incorrect procedure, but from ignoring the fact that the adjacent (105) reflex can overlap. The absence of the plate effect of the orientation is characteristic of the orientation of crystallites in PET fibers. The evidence of this absence is the nearly identical azimuthal intensity distributions of the diffracted radiation in the reflexes originating from different families of lattice planes. The lack of the plate effect of orientation in the case of PET fiber stretching has to do with the rod mechanism of the crystallite orientation. [Pg.846]

The basic method allows the non-ideal heat effects of the system to be considered as they affect the plate-to-plate... [Pg.63]

We first note the very large differences in column performance for the two methods. Effective plates per second represents the speed characteristics of a column (e.g., the number of plates that can be generated in a given time interval) (13). As can be seen, HPLC is 100 to 1000 times faster than classTcal LC. (We shall discuss the differences between PLB and PB in the next section.) This improved performance arises mainly from the use of significantly smaller particle sizes in HPLC. Moreover, in classical LC, the mobile phase is delivered to the column by gravity feed, hence, the very low mobile phase velocities. In HPLC, it is desireable to improve performance... [Pg.228]

The efficiency of an open tubular column can be measured in several ways the most widely used methods are the number of theoretical plates (n), the nu3aber of effective theoretical plates (N), the height equivalent to a theoretical plate (HETP) or effective plate, the coating efficiency and the separation number (SM). No single method is ideal, standardization is lacking and... [Pg.85]

Figure 1.2 Plot of theoretical plate nunber (n), effective plate nunber (N) and separation nuober (SN) against the capacity factor for an open tubular column operated under isothermal conditions. (Reproduced with permission from ref. 41. Copyright Friedr. Vieweg Sohn). Figure 1.2 Plot of theoretical plate nunber (n), effective plate nunber (N) and separation nuober (SN) against the capacity factor for an open tubular column operated under isothermal conditions. (Reproduced with permission from ref. 41. Copyright Friedr. Vieweg Sohn).
The plate height, and thus the total number of theoretical or effective plates, depends on the average linear carrier gas velocity (van Deemter relationship) and, for a particular carrier gas, the efficiency will maximize at a particular flow rate. Only at the optimum carrier gas flow rate are n, N, and HETP Independent of the column length. The efficiency will also depend on the column diameter (see section 1.7.1) where typical values for n, N, and HETP for different column types can also be found. Values for n, N, and HETP are reasonably independent of temperature but may vary with the substance used for their determination, particularly if the test substance and statioKary phase are not compatible. [Pg.604]

Neff Effective plates NK/fl+k JP Useful for comparing columns... [Pg.23]

There is no heat transfer across the end plates, so the number of effective plates will be the total number of plates less two. [Pg.760]

Select an effective plate area of 0.75 m2, effective length 1.5 m and width 0.5 m these are typical plate dimensions. The actual plate size will be larger to accommodate the gasket area and ports. [Pg.762]

Effective plate dimensions length 1.5 m, width 0.5 m, thickness 0.75 mm. [Pg.792]


See other pages where Plate, effective plates is mentioned: [Pg.148]    [Pg.559]    [Pg.148]    [Pg.559]    [Pg.322]    [Pg.169]    [Pg.145]    [Pg.187]    [Pg.188]    [Pg.188]    [Pg.189]    [Pg.190]    [Pg.231]    [Pg.232]    [Pg.463]    [Pg.167]    [Pg.246]    [Pg.433]    [Pg.550]    [Pg.230]    [Pg.648]    [Pg.11]    [Pg.604]    [Pg.808]   
See also in sourсe #XX -- [ Pg.63 ]




SEARCH



Composite plating, additive effects

Compound plate effects

Compressibility Effects of Flow between Parallel Plates

Edge Effects with Cone and Plate

Effective number of plates

Effective plate height

Effective plate number

Effective plates

Effective plates per second

Effective theoretical plate

Effective theoretical plate number

Effectiveness factors flat plate catalyst pellets

Effectiveness factors flat plates

Plate composition effects

Plate, effective plates height

Plate, effective plates height, reduced

Plate, effective plates theoretical, definition

Plate, effective plates theory

Plate, effective plates volume, definition

Temperature effects composite plating

The Effective Plate Number

© 2024 chempedia.info