Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Phase system, choice

The choice of variables remaining with the operator, as stated before, is restricted and is usually confined to the selection of the phase system. Preliminary experiments must be carried out to identify the best phase system to be used for the particular analysis under consideration. The best phase system will be that which provides the greatest separation ratio for the critical pair of solutes and, at the same time, ensures a minimum value for the capacity factor of the last eluted solute. Unfortunately, at this time, theories that predict the optimum solvent system that will effect a particular separation are largely empirical and those that are available can be very approximate, to say the least. Nevertheless, there are commercially available experimental routines that help in the selection of the best phase system for LC analyses, the results from which can be evaluated by supporting computer software. The program may then suggest further routines based on the initial results and, by an iterative procedure, eventually provides an optimum phase system as defined by the computer software. [Pg.364]

The choice of the anion ultimately intended to be an element of the ionic liquid is of particular importance. Perhaps more than any other single factor, it appears that the anion of the ionic liquid exercises a significant degree of control over the molecular solvents (water, ether, etc.) with which the IL will form two-phase systems. Nitrate salts, for example, are typically water-miscible while those of hexaflu-orophosphate are not those of tetrafluoroborate may or may not be, depending on the nature of the cation. Certain anions such as hexafluorophosphate are subject to hydrolysis at higher temperatures, while those such as bis(trifluoromethane)sulfonamide are not, but are extremely expensive. Additionally, the cation of the salt used to perform any anion metathesis is important. While salts of potassium, sodium, and silver are routinely used for this purpose, the use of ammonium salts in acetone is frequently the most convenient and least expensive approach. [Pg.35]

As the individual components of a mixture are moved apart on the basis of their differing retention, then the separation can be partly controlled by the choice of the phase system. In contrast, the peak dispersion that takes place in a column results from kinetic effects and thus is largely determined by the physical properties of the column and its contents. [Pg.16]

The effect of molecular interactions on the distribution coefficient of a solute has already been mentioned in Chapter 1. Molecular interactions are the direct effect of intermolecular forces between the solute and solvent molecules and the nature of these molecular forces will now be discussed in some detail. There are basically four types of molecular forces that can control the distribution coefficient of a solute between two phases. They are chemical forces, ionic forces, polar forces and dispersive forces. Hydrogen bonding is another type of molecular force that has been proposed, but for simplicity in this discussion, hydrogen bonding will be considered as the result of very strong polar forces. These four types of molecular forces that can occur between the solute and the two phases are those that the analyst must modify by choice of the phase system to achieve the necessary separation. Consequently, each type of molecular force enjoins some discussion. [Pg.23]

It is clear that the first challenge facing the analyst is the choice of the phase system that is appropriate for the particular sample to be analyzed. Only after the phase system has been chosen, can the correct column be selected. It is therefore necessary to know the types and properties of the different stationary phases that are available and how to formulate the pertinent mobile phases that must be used with them. [Pg.48]

It has been shown that, in LC, the size of the distribution coefficient of a solute between the two phases determines the extent of its retention. As a consequence, the difference between the distribution coefficients of two solutes establishes the extent of their separation. The distribution coefficients are controlled by the nature and strength of the molecular interactions that takes place between the solutes and the two phases. Thus it is the choice of the phase system that primarily determines the separation that is achieved by the chromatographic system. [Pg.93]

The use of other important phase systems such as exclusion media, ion exchange media and polar stationary phases such as silica gel have not been discussed as this chapter is primarily concerned with sample preparation. The last chapter will give examples of the use of these other phase systems and explain the separations obtained on a basis of molecular interactions and, at that time, the subject of solvent choice will again be discussed. [Pg.236]

The examples given in this chapter illustrate how the basic mechanisms that control solute retention and, consequently, sample resolution can be changed and varied to achieve a particular separation. The choice of the best phase system for a particular LC analysis is not an art but can be deduced from the physical and... [Pg.319]

Apart from the choice of an appropriate stationary and mobile phase, the essential problem for PLC is to attain equilibrium in a three-phase system — between the stationary, mobile, and gas phases. In a nonequilibrated system, the velocity of the mobile phase in a thicker layer (i.e., the effect of solvent evaporation) is less in a lower part of an adsorbent. Such a situation leads to the diffusion of bands and deterioration of the adjacent bands separation. This can be minimized or avoided by prerunning the plate with the mobile phase before spotting of the sample and the saturated chromatographic chambers. [Pg.259]

The choice of the chromatographic system depends on the chemical character of the extracts being separated. The mobile phase should accomplish all requirements for PLC determined by volatility and low viscosity, because nonvolatile components (e.g., ion association reagents and most buffers) should be avoided. It means that, for PLC of plant extracts, normal phase chromatography is much more preferable than reversed-phase systems. In the latter situation, mixtures such as methanol-ace-tonitrile-water are mostly used. If buffers and acids have to be added to either the... [Pg.259]

In this chapter, we describe how experimental rate data, obtained as described in Chapter 3, can be developed into a quantitative rate law for a simple, single-phase system. We first recapitulate the form of the rate law, and, as in Chapter 3, we consider only the effects of concentration and temperature we assume that these effects are separable into reaction order and Arrhenius parameters. We point out the choice of units for concentration in gas-phase reactions and some consequences of this choice for the Arrhenius parameters. We then proceed, mainly by examples, to illustrate various reaction orders and compare the consequences of the use of different types of reactors. Finally, we illustrate the determination of Arrhenius parameters for die effect of temperature on rate. [Pg.64]

There is a very wide choice of pairs of liquids to act as stationary and mobile phases. It is not necessary for them to be totally immiscible, but a low mutual solubility is desirable. A hydrophilic liquid may be used as the stationary phase with a hydrophobic mobile phase or vice versa. The latter situation is sometimes referred to as a reversed phase system as it was developed later. Water, aqueous buffers and alcohols are suitable mobile phases for the separation of very polar mixtures, whilst hydrocarbons in combination with ethers, esters and chlorinated solvents would be chosen for less polar materials. [Pg.85]

The shape of an isotherm depends on the choice of adsorbate, substrate, temperature T and, in a solution-phase system, the solvent. [Pg.491]

NaClO, or else in the two-phase system but with a quaternary ammonium (viz. AUquat) ion as a phase-transfer catalyst, overoxidation to the corresponding carboxylic acid is obtained (entry 4). Therefore, by proper choice of the experimental conditions, a synthetically useful distinction in products formation can be made for the oxidation of primary alcohols, even though we are far from a satisfactory understanding of the reason behind this different behaviour. In fact TEMPO, as a well-known inhibitor of free-radical processes is allegedly responsible for the lack of overoxidation of an aldehyde to carboxylic acid (entry 3) this notwithstanding, TEMPO is also present under those conditions where the overoxidation does occur (eutry 4). Moreover, a commou teuet is that the formation of the hydrated form of an aldehyde (in water solution) prevents further oxidation to the carboxylic acid however, both entries 3 and 4 refer to water-organic solutions, and their... [Pg.734]

Reaction engineering helps in characterization and application of chemical and biological catalysts. Both types of catalyst can be retained in membrane reactors, resulting in a significant reduction of the product-specific catalyst consumption. The application of membrane reactors allows the use of non-immobilized biocatalysts with high volumetric productivities. Biocatalysts can also be immobilized in the aqueous phase of an aqueous-organic two-phase system. Here the choice of the enzyme-solvent combination and the process parameters are crucial for a successful application. [Pg.425]

At this point, we have to decide which system (A or B) is selected as the reference phase. Our choice determines the actual form of the overall transfer law and explains the asymmetry between the two phases which we meet, for instance, in the equations expressing air-water exchange (see Chapter 20, Eq. 20-3). Here we choose A as the reference system. Then ... [Pg.844]


See other pages where Phase system, choice is mentioned: [Pg.110]    [Pg.130]    [Pg.110]    [Pg.130]    [Pg.1289]    [Pg.4]    [Pg.62]    [Pg.403]    [Pg.284]    [Pg.212]    [Pg.144]    [Pg.234]    [Pg.181]    [Pg.24]    [Pg.589]    [Pg.611]    [Pg.623]    [Pg.1343]    [Pg.1541]    [Pg.214]    [Pg.18]    [Pg.80]    [Pg.288]    [Pg.247]    [Pg.50]    [Pg.25]    [Pg.180]    [Pg.96]    [Pg.228]    [Pg.317]    [Pg.274]    [Pg.422]   
See also in sourсe #XX -- [ Pg.94 , Pg.95 ]




SEARCH



Choice of Phase Systems in MD-LC

Mobile phase system choice

System choice

© 2024 chempedia.info