Packing the Column

Packing. The column should spread the returning liquid over a considerable surface so that the exchange with the vapour is facilitated. [Pg.96]

There are no commercial columns designed for HOPC. The user must pack the column with suitable porous materials. [Pg.617]

Satisfactory operation must be between the upper and lower limits for both liquid and vapor flow rates. At liquid rates below 0.5 GPM per square foot of packing cross-section, liquid distribution is not uniform enough to ensure thorough wetting. At liquid rates between 25 GPM and 70 GPM per square foot of packing, the column is considered liquid-loaded and becomes very sensitive to additional liquid or vapor flow. [Pg.299]

It is important to wet-pack the column with the eluting solvent. Dry packing results in strong retention of the sample and poor separation, possibly because the small amount of ether in the eluting... [Pg.10]

Ceramic and metal packings are normally dumped into the column wet , to ensure a truly random distribution and prevent damage to the packing. The column is partially filled with water and the packing dumped into the water. A height of water must be kept above the packing at all times. [Pg.615]

Discotic LC are formed by disk-like molecules with aromatic cores and side chains that are either hydrophobic (i.e., thermotropic) or hydrophilic (i.e., lyotropic). The discotic nematic (No) phase behaves like a normal nematic phase formed by rod-like molecules, and the disk-like molecules are oriented with their short molecular axes parallel to the director but show no positional order. More ordered columnar phases are commonly formed by thermotropic discotics. The two-dimensional structure can pack the columns into a hexagonal or rectangular columnar phase, while within the columns, disks can be... [Pg.131]

Attaching an in-line end-frit and packing the column by pumping a slurry of beads and solvent into the capillary under high pressure. Sonication is recommended to achieve better quality. [Pg.15]

Chirica and Remcho first created the outlet frit, packed the column with ODS beads, and then fabricated the inlet frit. The column was filled with aqueous solution of a silicate (Kasil) and the entrapment achieved by heating the column to 160 °C [105,106]. The monolithic column afforded considerably reduced retention times compared to the packed-only counterpart most likely due to a partial blocking of the pores with the silicate solution. This approach was recently extended to the immobilization of silica beads in a porous organic polymer matrix [107]. [Pg.28]

To maximise separation efficiency requires low H and high N values. In general terms this requires that the process of repeated partitioning and equilibration of the migrating solute is accomplished rapidly. The mobile and stationary phases must be mutually well-dispersed. This is achieved by packing the column with fine, porous particles providing a large surface area between the phases (0.5-4 m2/g in GC, 200-800 m2/g in LC). Liquid stationary phases are either coated as a very thin film (0.05-1 pm) on the surface of a porous solid support (GC) or chemically bonded to the support surface as a mono-molecular layer (LC). [Pg.1081]

It is recommended that these washing steps be accomplished batch-wise prior to packing the column to avoid clogging the column filters or frits with fine particles or removed protein A. [Pg.31]

After packing, the column is extensively washed with met nol and/or... [Pg.247]

Equipment. A LDC (Laboratory Data Control) Constametric III pump was used together with a Rheodyne 7120 20 yl loop injection valve and two LDC Spectromonitor III, variable wavelength UV-detectors. A Stanstead constant pressure pump was used for packing the columns. [Pg.402]

To highlight the advantages of UPLC for quantitative bioanalysis, Yu et al. (2006) enriched rat plasma with alprazolam, ibuprofen, diphenhydramine, naproxen, and prednisolone and compared HPLC-MS/MS and UPLC-MS/MS approaches for quantification of ah five compounds. Apart from the particles that were used to pack the columns, ah other separation and mass spectrometry methods were kept as similar as possible. [Pg.35]

Important considerations when generating immunoaffinity columns include the conjugation of antibody to the supporting (column) material, packing the column, developing suitable washing and elution protocols, and constructing appropriate tests to evaluate column performance. Of primary importance to the utility of an... [Pg.141]

This protocol will concentrate on the methodology used to pack the column type shown in Figure 4.3. The basic layout normally includes a short column with a detachable column extension, the combined volume of which is sufficient to hold the total slurry volume. [Pg.63]


See other pages where Packing the Column is mentioned: [Pg.226]    [Pg.534]    [Pg.40]    [Pg.695]    [Pg.123]    [Pg.231]    [Pg.24]    [Pg.332]    [Pg.185]    [Pg.1090]    [Pg.27]    [Pg.13]    [Pg.15]    [Pg.82]    [Pg.85]    [Pg.371]    [Pg.10]    [Pg.144]    [Pg.71]    [Pg.4]    [Pg.71]    [Pg.20]    [Pg.219]    [Pg.185]    [Pg.143]    [Pg.66]    [Pg.478]    [Pg.339]    [Pg.168]    [Pg.169]    [Pg.116]    [Pg.265]    [Pg.53]   


SEARCH



Comparing Calculated and Experimental Values Throughout the Entire Operating Range of Packed Columns

Detection of Packed Column Maldistribution in the Field

Effect of Mobile Phase Compressibility on the HETP Equation for a Packed GC Column

Effective separating length the introduction of column packing

Models for the packed-bubble-column gas-liquid reactors

Packed Column Design by the Group Method

Packed columns

Packed columns, packing

The Absorption of CO2 by Aqueous NaOH in Packed Column

The Column Design Process for Packed Columns

The Design of Packed Columns for GC and LC

The Relationship between Dispersion in a Packed Column to Solute Molecular Weight

© 2024 chempedia.info