Outages, power supply

The reliability of the power supply should be determined, taking into account the frequency of power outages and extent of interruption. Consideration should be given to connecting electrically driven fire water pumps to the emergency power system, where one exists. [Pg.180]

In industrial electronics, DLCs can be used in uninterruptible power supplies (UPS), elevators, pallet trucks, etc. [90], They can be combined into large modules with integrated balancing that span outages in all power categories. In power-electronic, they are particularly suitable for backup in operation independent of the line voltage. A particular example is the power supply of wind turbine pitch system which is a market which is increasing very fast. [Pg.460]

Use fireproof cases, cabinets, and safes Continuity of electrical power in the presence of an electrical outage (e.g., use of an uninterruptable power supply — UPS) or surge (e.g., electrical condihoning)... [Pg.303]

In situations where it is not feasible to depend only on physical barriers, an isolation suite can be designed for working with these materials. Air locks and rooms that have negative differential pressure to the main hall ways are required, as well as HEPA-filtered inlet air and double-HEPA-filtered exhaust air. An uninterrupted power supply should be connected to the exhaust air handler to maintain a negative differential pressure if the suite is in operation during a power outage. If the exhaust air handler fails, all plant air handlers should be programmed to automatically turn off to minimize the potential for a positive differential pressure to develop. Each isolation suite may require a dedicated HVAC system.P l... [Pg.2883]

Power supplies - If there is an outage of local power an alternative may be provided so that service can continue. The substitute technology is not dependent on mains supply and may involve a mechanical generator or battery. It is also common for servers to be fed from two separate power supply units which are themselves fed from separate mains distribution circuits. [Pg.104]

Power. Ensure that a reliable uninterrupted power supply (UPS) is installed that guards against power outages and also surges/spikes in power. Ensure that the appropriate power supply, as specified by the manufacturer, is available. [Pg.364]

Conventional unintemiptible power supply (UPS) systems employ engine generators and/or batteries as their main sources to provide electric power for critical functions or loads when the normal supply, i.e. utility power, is not available [7], A typical UPS system consists of rechargeable batteries such as sealed lead-acid or nickel cadmium (Ni-Cd). However, these batteries contain toxic heavy metals such as cadmium, mercury, and lead that may cause serious environmental problems if they are discarded without special care [7], Further, unlike batteries, fuel cells provide continuous power for as long as reactants are supplied. This feature is especially useful whenever the duration of the power outage is uncertain. [Pg.279]

UPS with Diesel Generator. These systems combine an on-line UPS with backup generation to dehver a fuU, clean power supply during extended power outages. A battery bank keeps computers and processes in operation until the generator comes on-hne. [Pg.61]

Before power is distributed to computing eqnipment, however, it is fed to an uninterruptible power supply (UPS) system that acts as an energy supply buffer against utility power failures. UPS systems are designed to support less than a minute of demand, since diesel generators canjnmp into action within 15 seconds of a utility outage. [Pg.16]

Market based methods This is also known as revealed preference, as opposed to the stated preference obtained through surveys. When using this method the consequences of an outage are assessed based on the customers behavior on the market. Expenditures on backup facilities and the use of interruptible contracts can, for instance, provide information on how households or industries value interruptions of the power supply. [Pg.190]

The production function approach This method estimates the consequences of outages through lost production (for firms) or lost leisure time (for households). The cost is calculated as the ratio of an economic measure (e.g., gross output, gross domestic product GDP) and a measure of electricity consumption. The main benefit of the approach is that it makes use of readily obtainable data. The draw-back is that it makes unrealistic assumptions. For instance it says that if x% of the yearly power supply of a company is lost its yearly productivity will decrease by x%. However this... [Pg.190]

Loss of Power sequence, especially during maintenance of emergency diesel generators, is another important element. During outages, the full separation and drain supply is not always maintained. Studies found and operational experience confirmed that loss of a part of the power supply systems has caused complete loss of residual heat removal and similar. In this case, specific administrative limitation, like strict control of the power supply for the RHR pumps or the limitation of DCs maintenance depending on the availability of the second off-site power source were introduced. [Pg.28]

All such loads generate harmonics and cause variations in the fundamental power frequency of the supply sy.stem which leads to distortion in the sinusoidal waveform of the voltage. This distortion may affect the quality of the supply system (voltage) beyond desirable limits, A non-sinusoidal and distorted supply system may adversely affect the different loads connected on the system, besides leading to outage of the sy.stem itself. [Pg.785]


See other pages where Outages, power supply is mentioned: [Pg.273]    [Pg.273]    [Pg.311]    [Pg.599]    [Pg.170]    [Pg.173]    [Pg.423]    [Pg.461]    [Pg.599]    [Pg.599]    [Pg.310]    [Pg.554]    [Pg.124]    [Pg.386]    [Pg.670]    [Pg.61]    [Pg.57]    [Pg.81]    [Pg.1162]    [Pg.53]    [Pg.57]    [Pg.77]    [Pg.327]    [Pg.190]    [Pg.428]    [Pg.296]    [Pg.2918]    [Pg.46]    [Pg.522]    [Pg.170]    [Pg.68]    [Pg.11]    [Pg.21]    [Pg.193]    [Pg.1117]    [Pg.162]    [Pg.416]    [Pg.10]   
See also in sourсe #XX -- [ Pg.350 , Pg.354 ]