Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Operation scanning

Bonnell D A 1993 Microscope design and operation Scanning Tunnelling Microscopy and Spectroscopy ed D A Bonnell (Weinheim VCH) ch 2... [Pg.1720]

CR Yellow Alert Gas leak in MSM Audible alarm, yellow flashing light on fire gas panel Uncertain could be real 1. Accept alarm 2. Cz area technician 3. Make PA announcement 4. Determine which gas detector is in alarm (its location) Suspend current operation. Scan panels for flashing yellow or red light. Turn around to MSM Fire Gas panel. Press "accept" button CCR Layout MSM Fire Gas panel Visual and audible Whatever op is doing when alarm occurs Initially disorientating because MSM does not have its own sound source. Alarm could be missed if second simultaneous alarm occurs on main bank of Fire Gas panels... [Pg.343]

A designer of lighting systems was called in. He recommended surface mounted fluorescent fixtures, which he considered more efficient than the recessed ones. The laboratory operator scanned all work areas with a light meter after the job was completed. The light was even and well within recommended levels. Fiirther-more, there were never any problems with the fixtures themselves, except for an occasional change of tubes. [Pg.146]

In subprograms for operating scanning devices, the primary algorithm may include a do and wait operation (for a stepper motor) or a do and look operation (for a servo system). Try to avoid problems that could arise if you move your software to a faster, newer PC. With a new PC running at a faster clock speed than an old one, the faster do operation will require a longer wait if the scanner operation is matched to the duration of do + wait. Thus, the CAM should be treated as three separate units the microscope, the interface, and the PC. The PC will become obsolete before the microscope. [Pg.138]

Besocke, K. (1987). An easily operable scanning tunneling microscope. Surf. Sci. 181, 145-155. [Pg.385]

The next stage of characterization focuses upon the different phases present within the catalyst particle and their nature. Bulk, component structural information is determined principally by x-ray powder diffraction (XRD). In FCC catalysts, for example, XRD is used to determine the unit cell size of the zeolite component within the catalyst particle. The zeolite unit cell size is a function of the number of aluminum atoms in the framework and has been related to the coke selectivity and octane performance of the catalyst in commercial operations. Scanning electron microscopy (SEM) can provide information about the distribution of crystalline and chemical phases greater than lOOnm within the catalyst particle. Differential thermal analysis (DTA) and thermogravimetric analysis (TGA) can be used to obtain information on crystal transformations, decomposition, or chemical reactions within the particles. Cotterman, et al describe how the generation of this information can be used to understand an FCC catalyst system. [Pg.27]

The instrument was operated scanning from m/z 150-650 in 1 second using positive or negative ion detection (the most sensitive mode for the particular compound). The instrument was tuned daily and calibrated with polypropylene glycol (MW 425 and 1000). [Pg.16]

It is our practice to perform a stimulated Tg assay at the time of the initial post-operative scans. This is repeated... [Pg.1019]

A barcode basically is a machine-readable visual representation of information printed on the surface of objects. There are several different kinds of barcodes, for example, barcodes which store data in the widths and spacing of printed parallel lines, and those that store data within the patterns of dots, or concentric circles, or even hidden within images. This encoded data on the barcodes is read by barcode readers, which update the backend ERP, SCM, or WMS systems. However there are some inherent issues with using a barcode, for instance, barcodes become ineffective in rain, fog, snow, dirt and grime, and so forth (Tecstra, n.d.). Since barcodes rely on optical sensors, any minor change on the barcode print can make it difficult to read. This can be commonly seen at point of sale (POS) in the supermarkets, where the POS operator scans the barcode several times because it is either wet or not aligned properly. [Pg.113]

Figure 2 Schematic illustration of basic AFM operation. Scanning occurs either by translating the cantilever or the sample stage via piezoelectric crystals. A laser reflected from the back of the cantilever measures its deflection. Figure 2 Schematic illustration of basic AFM operation. Scanning occurs either by translating the cantilever or the sample stage via piezoelectric crystals. A laser reflected from the back of the cantilever measures its deflection.
Depending on the mode of operation (scan at constant rate, isothermal, temperature modulated), effects such as melting, crystallization, glass transition, and reversing melting can be studied. After a short introduction on the different techniques, some applications and limitations of the techniques are discussed. The examples on applications are limited to semicrystalline and glass-forming polymers, and chemical reactions and other applications are not considered. [Pg.794]


See other pages where Operation scanning is mentioned: [Pg.56]    [Pg.269]    [Pg.161]    [Pg.602]    [Pg.244]    [Pg.743]    [Pg.1015]    [Pg.807]    [Pg.1218]    [Pg.100]    [Pg.499]    [Pg.148]   
See also in sourсe #XX -- [ Pg.145 , Pg.178 ]




SEARCH



© 2024 chempedia.info