Open contact

The NO (normally open) contact of I/C-1 (520 is wired in the trip circuit of I/C-2 (52 ii) and vice versa. As soon as an interrupter is closed, the tripping circuit of the other gets ready to trip. [Pg.381]

To provide an insulating barrier between the open contacts after the arc is extinguished. [Pg.633]

It is sometimes possible to close an odorous system in order to prevent the release of the odor to the atmosphere. For example, a multiple-effect evaporator can be substituted for an open contact condenser on a process emithng odorous, noncondensable gases. [Pg.486]

The fact that oil was effective for the extinction of the arc formed between the opening contacts of a circuit breaker was discovered towards the end of the nineteenth century. In a bulk oil circuit breaker the oil is used both as the medium for arc extinction and as the insulating material of the contacts. The contacts are contained within a... [Pg.212]

If the spring pressure is overcome, the switch will open and stop the compressor. Normally open contacts on the cut-out can then operate a warning. The cut-out point only needs to be some 2 bar higher than the expected summer operating pressure but there is a... [Pg.105]

Operation of the oil safety cut-out indicates an unsafe condition and such controls are made with hand reset switches. Normally open contacts on the switch can be used to operate an alarm to warn of the malfunction. [Pg.107]

As she was being shunted from one Italian town to the next, Seraphina brooded on the state of her soul and the image of her loving family. In Roveredo, she plucked up the courage to make open contact with a Catholic priest. Clementino Vannetti sensed the importance of this moment ... [Pg.202]

Contacts are represented as vertical bars. A vertical bar represents a normally open contact power flows through this contact only if the device with which the contact is associated is actuated (energized). Vertical bars separated by a slash represent a normally closed contact power flows through this contact only if the device with which the contact is associated is not actuated. The level switches actuate on rising level. If the vessel level is below the location of the switch, the normally open contact is open and the normally closed contact is closed. If the level is above the location of the switch, the normally closed contact is closed and the normally open contact is open. [Pg.50]

The second rung is an almost identical circuit for pump B. The difference is the use of the normally open contact on the coil LeadlsB. [Pg.50]

LL was actuated on the previous scan of ladder logic (note the use of the normally open contact for LL1)... [Pg.51]

In the DFT method [80], each individual pore has a fixed geometry and is in open contact with the bulk vapor-phase adsorbate at a fixed temperature. For this system, the grand canonical ensemble provides the appropriate description of the thermodynamics. In this ensemble, the chemical potential jx, temperature T, and pore volume F are specified. In the presence of a spatially varying externd potential Fext, the grand potential functional of the fluid is [15]... [Pg.227]

Anchor. The next step is to open contact holes through the sacrificial oxide to the ground-plane polysilicon layer and/or the n+ runners. These contacts become the electrical and mechanical interconnections or anchors for the mechanical polysihcon structure (Fig. 5.2.6). A wet-dry etch combination provides a... [Pg.97]

Cellular Systems. Superficially, these closely packed systems are much like some of those just discussed, but the stiffness now derives from the rigidity of the continuous mass rather than the particles. Three main types are distinguished solid foams gas-filled sponges (where the cells are in open contact with each other) and plant tissues (where the cells are largely filled with liquid). [Pg.788]

FIGURE 246. Depictions of aspects of Humphry Davy s Safety Lamp for Coal Miners (London, 1818)- His ingenious solution to lamps that would ignite coal gas with deadly results was incredibly simple- The fine metallic mesh would cool the coal gas below its flash point. Thus, although the flame and combustible gas were in open contact, there would be no explosion. [Pg.407]

Vacuum and SF6 devices were developed at about the same time as competitors. There is little to choose between them since they are both simple mechanisms. Some engineers in the past considered the possibility that the vacnnm conld be lost while the circuit breaker was in its on state was a serions disadvantage. However, the technology has greatly improved and thousands of vacnnm circnit breakers are in service. Vacuum circuit breakers are limited to about 13.8 kV due to insulation difficulties across the open contacts. Current ratings at 13.8 kV are limited to about 3000 A, with corresponding fault making duties up to 100 kA peak. SF6 equipment tends to be preferred to vacuum equipment. [Pg.147]

Within the areas of water and waste water, photochemistry may be the result of open contact chambers or it may be used as a treatment process to control organic compounds or for disinfection. Within atmospheric studies, numerous photochemically induced reactions occur in cloud droplets. [Pg.1]

Epoxy/reinforced can be used for molds for open (contact), and low-pressure cold-press molding. Epoxy molds have poor temperature control and tend to be fragile. Compoimding with a metal filling improves heat conductivity but, in general, epoxy molds should only be used for short runs or for prototype parts, when quality is not the key criterion, but cost and flexibility are paramount. [Pg.425]

Mechanical joints to assemble RP moldings to each other or to other components usually employ metal inserts or fixtures (also used are RP and URP types), which are molded into the product. With open/ contact molding, this can readily be organized within the scope of the molding cycle. For press molding of both TSs and TPs, it can often be a... [Pg.459]

The typical MAC is of the open contact Break Glass type, suitable for Division 1 locations. MACs should be covered with a guard to prevent inadvertent alarm activation. Alternatively, the MAC can be actuated by a pulling action (to prevent spurious trips caused by someone pushing the button by mistake). The emergency response system should tell the operators and ERT which MAC was activated. [Pg.535]

Supports are positioned to rest on the tank bottom and extend to the height of the tank sides. On these supports the floor for the pile is laid, which is also the lid of the 65 melting, under such cooling as may be obtained from the outlet water tank. This floor is pierced with openings contact with the atmosphere. [Pg.682]

Output of the central door lock. The lock cable connected to the executor of the central door lock is u ua% grounded through the normally-closed contact of the internal relay when the door is locked by the remote controller or locked manually, the public contact of the relay will get through the normally-open contact, realizing an output of 12V voltage. [Pg.351]

A switch used on guard doors that is used to detect if the door is opened while the machine is running, and uses a coded actuator to prevent intentional defeat. Safety interlock switches use positive opening contacts, which ensure that the closed switching contact is forced open when the guard is opened, without reliance upon spring action. [Pg.261]