Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Insulation barrier

The Hquid monomers are suitable for bulk polymerization processes. The reaction can be conducted in a mold (casting, reaction injection mol ding), continuously on a conveyor (block and panel foam production), or in an extmder (thermoplastic polyurethane elastomers and engineering thermoplastics). Also, spraying of the monomers onto the surface of suitable substrates provides insulation barriers or cross-linked coatings. [Pg.342]

To provide an insulating barrier between the open contacts after the arc is extinguished. [Pg.633]

Thermal oxidizers must be built to provide the residence time and temperatures to achieve the desired destruction efficiency (DE). As such, thermal oxidizers are comparatively larger than catalytic oxidizers since their residence time is two to four times greater. Historical designs of thermal oxidizers were comprised of carbon steel for the outer shell and castable refractory or brick as the thermal liner (a refractory is like a cement, which is put on the inside of the rector shell to act as a thermal insulation barrier). Modern units are designed and built using ceramic fiber insulation on the inside, which is a lightweight material, and has a relatively long life. Old refractory would tend to fail over a period of years by attrition of expansion and contraction. [Pg.482]

These coatings bubble and foam to form a thermal insulation when subjected to a fire. They have been used for many decades. Such coatings cannot be differentiated from conventional coatings prior to the occurrence of a fire situation. Thereupon, however, they decompose to form a thick, nonflammable, multicellular, insulative barrier over the surface on which they are applied. This insulative foam is a very effective insulation that maintains the temperature of a flammable or heat distortable substrate below its ignition or distortion point. It also restricts the flow of air (oxygen) to fuel the substrate. [Pg.400]

To remove this unwanted heat (also known as thermal management), it is often necessary to use hybrid circuits and bulky heat-dissipation devices or complicated and expensive refrigeration. Metals with good thermal conductivity, such as copper or aluminum, are presently used as heat sink materials but, since being metals they also have high electrical conductivity, they require an electrical-insulation barrier. [Pg.375]

Schiffrin and coworkers have reported about how control of the transparency of the insulation barriers between... [Pg.118]

Figure 2 is a detail of the sloped wood cap used in Figure 1. Note that the joints are taped (at the top of the cant) and caulked (between the lead flooring and wood cant) to keep manufacturing components and product out of joints. The tape material is 3 inch wide, 2 ply, 100 percent cotton, grade B fabric with a warp and fill of approximately 78 x 78 x 72 pounds breaking strength. It should be adhesive-applied using a water insoluble nitrile rubber/ resin solution. These are commonly referred to as "Airplane Fabric" and "Pliobond 20" adhesive. The Fiberfrax Paper is used below lead flooring as an insulation barrier with a low thermal conductivity to resist heat required for installation of lead conductive floor. Note also that nonsparking nails are required. These are usually aluminum or brass. Figure 2 is a detail of the sloped wood cap used in Figure 1. Note that the joints are taped (at the top of the cant) and caulked (between the lead flooring and wood cant) to keep manufacturing components and product out of joints. The tape material is 3 inch wide, 2 ply, 100 percent cotton, grade B fabric with a warp and fill of approximately 78 x 78 x 72 pounds breaking strength. It should be adhesive-applied using a water insoluble nitrile rubber/ resin solution. These are commonly referred to as "Airplane Fabric" and "Pliobond 20" adhesive. The Fiberfrax Paper is used below lead flooring as an insulation barrier with a low thermal conductivity to resist heat required for installation of lead conductive floor. Note also that nonsparking nails are required. These are usually aluminum or brass.
Electronic industry Thin films for insulating barriers or masks for etching processes XY machine tables for VLSI semiconductor manufactures ... [Pg.145]

A p-n junction can be used to rectify an electric current, that is, to make it much easier to pass in one direction than the other. The depletion of carriers for the junction effectively forms an insulating barrier. If positive potential is applied to the n-type side (a situation known as reverse bias), more carriers are removed and the barrier becomes wider. However, under forward bias the n-type is made more negative relative to the p side, so that the energy barrier is decreased and the carriers may flow through. [Pg.130]

In 1962 a postgraduate student, Brian Josephson, working in the University of Cambridge, and later to win a Nobel Prize, predicted that Cooper pairs should be able to tunnel through a thin (approximately 1 nm) insulating barrier from one superconductor to another with no electrical resistance [46]. This quantum tunnelling was confirmed by experiment and is known as the Josephson effect . The superconducting electronic devices exploit Josephson junctions. [Pg.233]


See other pages where Insulation barrier is mentioned: [Pg.309]    [Pg.476]    [Pg.371]    [Pg.272]    [Pg.110]    [Pg.346]    [Pg.636]    [Pg.636]    [Pg.279]    [Pg.327]    [Pg.190]    [Pg.108]    [Pg.118]    [Pg.645]    [Pg.230]    [Pg.203]    [Pg.125]    [Pg.126]    [Pg.127]    [Pg.6]    [Pg.270]    [Pg.222]    [Pg.146]    [Pg.663]    [Pg.663]    [Pg.371]    [Pg.110]    [Pg.153]    [Pg.278]    [Pg.562]    [Pg.161]    [Pg.46]    [Pg.187]    [Pg.327]    [Pg.178]    [Pg.141]    [Pg.164]    [Pg.254]    [Pg.449]   
See also in sourсe #XX -- [ Pg.445 ]




SEARCH



© 2024 chempedia.info