Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Ongoing servicing

Observations have shown that the cause of the greatest number of faults even in the best HR systems is poor-quality servicing during production. [Pg.321]

Rigorous measures must therefore be put in place to prevent  [Pg.321]

Breaks in operation. Some plastics, e.g., PC, may remain in the injection machine cylinder or in the HR system even after a dozen hours when the temperature is set to around 160 °C. The phenomenon of very strong adhesion between the metal surface of the cylinder and the solidified melt may even cause detachment of the nitrided layei and it is therefore recommended that purging with HOPE always be carried out before any lengthy stoppage. There are no recommendations here for HR systems, but this should be borne in mind particularly for nozzle components with a nickel coating or made of sintered materials. [Pg.321]

End of operation. The procedure is similar to that used in the injection moulding machine  [Pg.321]

High temperature plastics should be purged with PC after a temperature reduction, and then when a second temperature reduction has taken place, with HDPE or PP. [Pg.322]


Outsource regularly used in-house services that provide no competitive advantage, for example IT and computing, information library support and routine analytical services, by agreeing an ongoing service contract with a specialist organisation. [Pg.89]

If the SAP determines that the driver needs ongoing services the SAP must provide recommendations in his/her follow-up evaluation report. The driver is required to comply with the SAP s recommendations. [Pg.99]

The Hazardous Materials Regulations of DOT and similar regulations of TC require that cylinders be periodically requalified including a visual inspection to determine their suitability for ongoing service. A formal visual inspection is authorized instead of the periodic hydrostatic retest for certain low pressure cylinders dedicated for noncorrosive gas service. Specific details for this allowance can be found in DOT regulations under 49 CFR 173.34, or CAN/CSA B339 and B340 [1, 3, 4]. Otherwise, visual inspection is a mandatory supplement to a hydrostatic test. [Pg.172]

The Hazardous Materials Regulations of the U.S. Department of Transportation and similar regulations of Transport Canada require that cylinders be visually inspected to determine their suitability for ongoing service at a prescribed pressure. Note that for the purpose of this discussion, a tube trailer tube may be thought of as a large high pressure cylinder. [Pg.168]

This presentation will not attempt to present all these projects, but instead focus on the ongoing network activities and the available sources for further information through the Commission s information services, with the CORDIS database being the prime source of information (see details at the end of the paper). [Pg.932]

The achievement of more effective levels of quality requires systematic planning and budgeting. There should be evidence of ongoing effort to identify variability in the quality of service and plans for improvement in areas that will have major benefits to the client. [Pg.193]

Installation of a new plant may cause serious disruption of the user s ongoing business, and the extent of this disruption should be determined before it is too late. Apart from the installation of the plant itself, there is the associated builders work and the temporary disconnection of other services. The use of factory-built packaged equipment helps to reduce this nuisance. [Pg.121]

O Antithrombotic therapies require meticulous and systematic monitoring, as well as ongoing patient education. Well-organized anticoagulation management services improve the quality of patient care and reduce the overall cost. [Pg.133]

Emergency Service Procedures and Facilities undergoing ongoing modification, as extreme weather risks are too unpredictable to be fully contained (IDNDR s research units for hazard mitigation and/or disaster preparedness are in place at the Universite de Quebec a Rimouski, the University of Manitoba, the University of British Columbia). [Pg.62]

Technical audits of SCADA devices and networks are critical to ongoing security effectiveness. Many commercial and open-source security tools are available that allow system administrators to conduct audits of their systems/networks to identify active services, patch level, and common vulnerabilities. The use of these tools will not solve systemic problems, but will eliminate the paths of least resistance that an attacker could exploit. Analyze identified vulnerabilities to determine their significance, and take corrective actions as appropriate. Track corrective actions and analyze this information to identify trends. Additionally, retest systems after corrective actions have been taken to ensure that vulnerabilities were actually eliminated. Scan nonproduction environments actively to identify and address potential problems. [Pg.131]

This chapter is devoted to the subject matter of electrochemistry in the service of, and how it relates to, medicine. It is indeed timely for this kind of topic to be discussed in a book such as this one. Medicine is the second-oldest profession, and as such, alone deserves our closer attention. Further, in the ongoing process of globalization, we are witnessing not only the tendency of commercial unification of the globe but the rapidly emerging interdependency of different scientific and technical disciplines as well. [Pg.351]

Over 5001 of HLW have been vitrified in France and Germany. In the USA, the HLW at the Nuclear Fuel Services plant in West Valley Plant, New York, have been vitrified (300 two-ton canisters) and vitrification is ongoing at the Defense Waste Processing Facility (DWPF) at Savannah River, South Carolina 1600 canisters by February 2004). A vitrification plant is under construction at Hanford, Washington. Vitrification of all of the HLW in the USA will generate approximately 20 000 canisters, which are destined for disposal at the geological repository at Yucca Mountain. [Pg.16]

Discussion It is important that the apparatus assigned to the companies and personnel of this department be available to answer any and all alarms to ensure the safety of this community. Over the past few months, there have been reports that minor problems with apparatus have not been addressed in a timely manner. This is a concern due to the high number of reports of accidents and incidents involving fire service vehicles in the United States. This order will establish a method to ensure that there is a program to inspect and report the findings to the Mechanic s Office before a minor problem becomes the cause of a failure. The Mechanic s Office has an ongoing program... [Pg.280]


See other pages where Ongoing servicing is mentioned: [Pg.118]    [Pg.231]    [Pg.321]    [Pg.45]    [Pg.173]    [Pg.118]    [Pg.231]    [Pg.321]    [Pg.45]    [Pg.173]    [Pg.519]    [Pg.194]    [Pg.348]    [Pg.63]    [Pg.507]    [Pg.255]    [Pg.134]    [Pg.270]    [Pg.3]    [Pg.74]    [Pg.515]    [Pg.234]    [Pg.507]    [Pg.221]    [Pg.106]    [Pg.141]    [Pg.75]    [Pg.19]    [Pg.456]    [Pg.257]    [Pg.132]    [Pg.409]    [Pg.252]    [Pg.564]    [Pg.391]    [Pg.26]    [Pg.60]    [Pg.194]    [Pg.47]    [Pg.161]    [Pg.120]   


SEARCH



© 2024 chempedia.info