Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Numerical data format

The Web-based graphical user interface permits a choice from numerous criteria and the performance of rapid searches. This service, based on the chemistry information toolkit CACTVS, provides complex Boolean searches. Flexible substructure searches have also been implemented. Users can conduct 3D pharmacophore queries in up to 25 conformations pre-calculated for each compound. Numerous output formats as well as 2D and 3D visuaHzation options are supplied. It is possible to export search results in various forms and with choices for data contents in the exported files, for structure sets ranging in size from a single compound to the entire database. Additional information and down-loadable files (in various formats) can be obtained from this service. [Pg.263]

Figure 9.2-2 shows a data input screen in which general characteristics are input by radio buttons and numerical data is typed. The program calculates distances to specified in.sic concentrations and other requested consequence levels automatically. Results are available in a variety of formats including cloud footprints, sideview, cross section, pool evaporation rate, concentration vs distance and heat flux contours. Figure 9.2-3 shows the calculated results as a toxic plume. superimposed on the map with and without oligomerization. [Pg.359]

Abstract. Auto-accelerated polymerization is known to occur in viscous reaction media ("gel-effect") and also when the polymer precipitates as it forms. It is generally assumed that the cause of auto-acceleration is the arising of non-steady-state kinetics created by a diffusion controlled termination step. Recent work has shown that the polymerization of acrylic acid in bulk and in solution proceeds under steady or auto-accelered conditions irrespective of the precipitation of the polymer. On the other hand, a close correlation is established between auto-acceleration and the type of H-bonded molecular association involving acrylic acid in the system. On the basis of numerous data it is concluded that auto-acceleration is determined by the formation of an oriented monomer-polymer association complex which favors an ultra-fast propagation process. Similar conclusions are derived for the polymerization of methacrylic acid and acrylonitrile based on studies of polymerization kinetics in bulk and in solution and on evidence of molecular associations. In the case of acrylonitrile a dipole-dipole complex involving the nitrile groups is assumed to be responsible for the observed auto-acceleration. [Pg.251]

The enthalpy of formation data appear in Table 1. Where there are numerous data for structurally related compounds, plotting the enthalpy of formation versus the number of carbons can reveal at a glance the quality of the data. For the alkyl hydroperoxides especially, the data are seen to be of mixed quality as evidenced by the lack of linearity in the plot (Figure 1). The error bars for the ethyl and n-propyl hydroperoxides are so large as to render the data meaningless. Also, the enthalpy of formation of n-propyl hydroperoxide is more negative than that of 1-hexyl hydroperoxide, another indication of its gross inaccuracy. The C2 and C3 hydroperoxide data will not be considered any further. [Pg.147]

Attention was paid to the explosive properties of ammonium nitrate as early as 1883 by Berthelot [10] who first formulated the equation of decomposition, and gave the numerical data for the heat of explosion, heat of formation, the volume of gases evolved and the temperature of explosion. [Pg.455]

There is abundant evidence that steric hindrance to coordination will decrease the formation constant of any complex formed and may even inhibit complex formation altogether. Numerical data are available for transition metals and substituted ethylenediamines,27 or substituted oxines.-3 for 1,10-phenanthroline and its 2- and 2,9-methyl-substituted derivatives28 and for other systems.29 Since the introduction of a 2-methyl substituent into oxine diminishes 0 while increasing pK2, it is not surprising that the effective concentration [Al(2-MeOxine)3] may not be great enough to cause precipitation, although this is achieved in non-aqueous media such as ethanol. [Pg.530]

Another way to get a structure into the computer is to import (read) a molecule file containing the atomic co-ordinates (and perhaps other atomic and molecular information) into your program. Unfortunately, there is no single standard file format that all programs use. However, some of the commonly encountered formats include those of SYBYL MOL2 files and Protein Data Bank (PDB) files. There are also free programs available for download from the World Wide Web that can interconvert the numerous file formats still in use. [Pg.383]

The estimate for the non-trivial knot formation probability, p(a) in the region a < 0.6 with numerical constants obtained by comparing the relation (46) with numerical data of Ref. [29] is shown in Fig. 8 by the solid line for... [Pg.27]

Overall, it seems that PHREEQC, except for the problems with high ionic strengths that require the application of PITZER equations, is the optimal program for the solution of both simple and more complex exercises and for onedimensional transport modehng with regard to user-friendliness, numerical stability, compactness and clarity of the data format as well as flexibility. It will be used for the solution of the exercises in chapter 3. The utilization of PHREEQC is presented in detail in chapter 2.2. [Pg.74]

In chemometrics we want to perform operations on numerical data. There are many ways of getting information into Matlab generally straight into matrix format. Some of die simplest are as follows. [Pg.466]

There are a number of difficulties encountered with quantification after employing derivatization. These include the fact that we are now considering another analytical step, with the concomitent increase in cost and time of each analysis. In addition, because derivatization is another handling stage in the analytical process, there is always the risk of sample contamination. Furthermore, the assumption is made that the derivatization reactions are complete and that the corresponding derivatives are stable for the period between derivative formation and analysis. Further factors are that dilutions need to be extremely accurate and precise to obtain reliable numerical data and that derivatization can potentially lead to increases in numerical errors for such data. [Pg.25]

The liquid propellant rocket combination nitrogen tetroxide (N2O4) and UDMH (unsymmetrical dimethyl hydrazine) has optimum performance at an oxidizer-to-fuel weight ratio of 2 at a chamber pressure of 67 atm. Assume that the products of combustion of this mixture are N2, CO2, H2O, CO, H2, O, H, OH, and NO. Set down the equations necessary to calculate the adiabatic combustion temperature and the actual product composition under these conditions. These equations should contain all the numerical data in the description of the problem and in the tables in the appendices. The heats of formation of the reactants are... [Pg.32]

Establish the format of the numeric data if it is different from the default values. This can be done globally (affecting the entire spreadsheet) or locally (affecting only a specified part of the spreadsheet). [Pg.308]

Numerical data are a result of a literature search performed in the CAS database using the software SciFinder Scholar 2000. This search could not cover aU immunoassay publications, but was limited only to the ones in which the assay format (competitive or non-competitive) was specified. We consider, however, that the probability for the assay format to be mentioned is the same for both competitive and non-competitive immunoassays. [Pg.599]

Note that the text is wrapped within cells, which makes the table of data somewhat difficult to read. You can manually change the width of the columns as discussed previously, but there is a better and more automatic way to improve the appearance and readability of the table. The table of data should already be highlighted, so click on Format/Cells..., click on the Alignment tab, click twice to uncheck the Wrap button, and click on OK. Finally, click on Format/ Column.../AutoFit Selection, and your worksheet should be formatted and readable as shown in Figure 3-10. Scroll down the worksheet, and notice that each column is now exactly the correct width to accommodate the largest number of characters in the column and that no cells have wrapped text. Text in the cells is left justified, and numerical data are right justified. [Pg.62]

Such numerical data are not available from analyses of in vivo solutions, since the total metal concentration may not change, but can conveniently be calculated using computer simulation of the multiple equilibria present in biological fluids. These are based upon formation constants, upon total quantities of each of the materials present, and upon large computer programmes which calculate the distribution of metal ions at concentrations below those normally available to analytical chemists. [Pg.46]


See other pages where Numerical data format is mentioned: [Pg.148]    [Pg.148]    [Pg.354]    [Pg.131]    [Pg.84]    [Pg.307]    [Pg.98]    [Pg.533]    [Pg.167]    [Pg.145]    [Pg.292]    [Pg.309]    [Pg.322]    [Pg.225]    [Pg.131]    [Pg.60]    [Pg.386]    [Pg.81]    [Pg.59]    [Pg.129]    [Pg.60]    [Pg.94]    [Pg.97]    [Pg.34]    [Pg.410]    [Pg.225]    [Pg.70]    [Pg.229]    [Pg.1137]    [Pg.446]    [Pg.156]    [Pg.88]    [Pg.928]   
See also in sourсe #XX -- [ Pg.148 ]




SEARCH



Data, format

Numerical data

© 2024 chempedia.info