We might simply low-limit the steam and use no temperature control, erroneously expecting that this would provide overpurification at low loads. This structure is fatally flawed. [Pg.439]

Simply putting a low limiter on the reboUer steam flow rate and using no temperature control will not result overpurification. Remember that the control structure in use has a reflux-to-feed ratio. As the feed flow rate drops below 50% of design, the reflux also will drop below 50% of design. If the reboUer heat input is fixed at the 50% level, the lower reflux and the same vapor boilup will produce an increase in distillate. This will drive water up the column and sent the distillate off-spec. [Pg.439]

To demonstrate this problem, steady-state runs are made under conditions where the feed flow rate and the reflux flow rate are 49% of design, but the reboiler duty is varied from 49% to 50% of design. At 49% reboiler duty, the distillate water impurity is the specified 0.1 mol%. If reboiler duty is raised to 49.5%, distillate composition is 1.3 mol% water. At the set low-limit of 50% reboiler duty, distillate composition is 2.6 mol% water. These results demonstrate the strong effect of changes in the distillate flow rate that occur when the reflux is 49% of design while the reboiler duty is 50% of design. Simply low-limiting the steam will not work. [Pg.439]

Some other modification of the control stmcture would also be necessary. We might think of also limiting the reflux flow rate or switching to a reflux ratio scheme. However, neither of these will work in the face of feed composition disturbances. Control of some temperature or composition in the column must be included in any workable control stmcture (Second Law of Distillation Control). [Pg.439]

To demonstrate this problem, steady-state mns are made at the 100% design level. Feed and reflux flow rate and reboiler duty are fixed at their 100% levels. There is no temperature control. Then very small changes are made in feed composition. Table 15.1 gives results when methanol feed composition is decreased from its design value of 81.53 mol% methanol with corresponding increases in water concentration. There is no temperature control. The effect on bottoms impurity is striking. [Pg.439]


The first microwave-assisted Suzuki reactions involving heteroaromatic skeletons were reported in 1996 [35]. Hallberg et al. Hnked the substrates 4-iodo and 4-bromobenzoic acid to a TentaGel-Rink resin (Scheme 16). Suzuki reactions on these soUd-phase-Unked substrates were easily performed in less than 4 min using a constant microwave irradiation power (45 W) (no temperature control Standard acidic cleavage with TEA yielded the corresponding biaryls with an excellent yield. [Pg.164]

No temperature control Is required because of the non-exothermic nature of this reaction. [Pg.30]

An HPLC assay, content uniformity and related compounds method for a blockbuster new drug product, was developed that utilized concave gradient elution, a flow rate of 1.25 ml/min and no temperature control of the column. Samples were placed in 1000-ml volumetric flasks, sample diluent was added, and the flasks were sonicated for 10 min followed by 30 min of mechanical shaking. This method was to be run in a QC laboratory at the contract manufacturing facility in Puerto Rico. While the developed method worked flawlessly in the development laboratory, the QC laboratory had many problems in performing the procedure. [Pg.149]

Microwave power output and sample weight seem to have minor effects on extraction efficiency. It was reported that the increase in oven power gave higher recovery of PAHs from atmospheric particles [82], The reason could be that the microwave system used in that study had no temperature control. [Pg.172]

Scheme 9 Model reactions for microwave-scale-up in open vessels (no temperature control)... Scheme 9 Model reactions for microwave-scale-up in open vessels (no temperature control)...
An important case is the application of enzymes in laundry detergents. Market trends in the United States show that consumers prefer liquids to powder detergents by a ratio of 2 to 1. These products are stored with no temperature control on shelves in the presence of harsh surfactants, such as linear alkylbenzyl sulfonate (LAS) and require extraordinary measures for stabilization. LAS, by its nature as an effective cleaning agent, causes surfactant-induced unfolding in proteins. There are countless examples of the development of stabilization systems in the intellectual property space. A common theme is to reduce the water activity and to use borate/glycol stabilizers that bind to the active site of proteases. [Pg.1340]

Latex stability. Effect of temperature. Usually no temperature control was imposed. The rise in temperature during the test was 1-2 °C. For purposes of temperature control the bottle containing the sample was provided with a water jacket through which water at specified temperature was circulated. The effect of temperature on the stability is described in Figure 9 To avoid confusion the experimental points are not indicated on the figure, except those obtained at room temperature. The temperature dependence was found to obey the Arrhenius equation. At any given emulsifier level a linear plot of the logarithm of the stability versus 1/T could be obtained. [Pg.268]

Most importantly, no temperature control is performed in these... [Pg.2242]

Two time acquisition windows (in the range of 0-1040 s and 1820-2120 s) are specifically analyzed in Figs. 6.13 and 6.14. In the first window, the stack power increases up to 1.8 kW, while no temperature control is adopted until 335 K. [Pg.178]

Volumetric handling +/- Non calibrated glassware No temperature control Dilution etc. carried out with calibrated glassware, temperature control... [Pg.36]

For example, if the temperature is controlled on tray 3, the bottoms composition will vary shghtly as reflux is changed. This is illustrated in Figure 12.94. With no temperature control in place, reflux has a huge effect on bottoms composition. With tray 3 under temperature control the bottoms composition is kept close to target but not exactly so. The controller is effectively keeping constant the composition of the hquid on tray 3. As reflux is increased more separation takes places between tray 3 and the base of the column, so improving the product purity. [Pg.335]

Besides the properties and the geometrical setup, the operating mode of the sensor device is important for the application and sensitivity. The heater can be operated in two modes [16] with constant electrical power or at a constant controlled temperature. With constant electrical heating power, the measurement of the temperature difference AT is appropriate for low liquid flow rates or gas flow. No temperature control is necessary for the heater. The heater cannot be overheated when an error occurs. Measuring the heater temperature 7h is suitable for liquid flow rates, but the fluid temperature has to be known. With... [Pg.2046]

Figure 3. Effect of temperature control on the stability of the UV detector. A = No temperature control of cell or column eluent. B = Cell and column eluent measured at the same temperature. Figure 3. Effect of temperature control on the stability of the UV detector. A = No temperature control of cell or column eluent. B = Cell and column eluent measured at the same temperature.

See other pages where No Temperature Control is mentioned: [Pg.53]    [Pg.214]    [Pg.369]    [Pg.163]    [Pg.140]    [Pg.1157]    [Pg.211]    [Pg.158]    [Pg.131]    [Pg.47]    [Pg.287]    [Pg.52]    [Pg.641]    [Pg.494]    [Pg.170]    [Pg.35]    [Pg.439]    [Pg.3287]    [Pg.219]    [Pg.442]    [Pg.46]    [Pg.338]    [Pg.219]    [Pg.191]   


SEARCH



Temperature control

Temperature control controllers

Temperature controller

Temperature-controlled

© 2024 chempedia.info