Molecular instrumentation

How does a double-beam atomic instrument differ from a double-beam molecular instrument ... [Pg.272]

Since the sample cuvette is the flame located in an open area of the atomic absorption instrument, rather than a glass container held in the light tight box in the case of molecular instruments, how is room light prevented from reaching the detector and causing an interference ... [Pg.272]

Proteins are the most abundant macromolecules in living cells, and 65% of the protein mass of the human body is intracellular. Proteins are the molecular instruments through which genetic information is expressed. All proteins are constructed from 20 amino acids joined by covalent bonds. AU 20 amino acids have the following group in common ... [Pg.79]

Flowever, in order to deliver on its promise and maximize its impact on the broader field of chemistry, the methodology of reaction dynamics must be extended toward more complex reactions involving polyatomic molecules and radicals for which even the primary products may not be known. There certainly have been examples of this notably the crossed molecular beams work by Lee [59] on the reactions of O atoms with a series of hydrocarbons. In such cases the spectroscopy of the products is often too complicated to investigate using laser-based techniques, but the recent marriage of intense syncluotron radiation light sources with state-of-the-art scattering instruments holds considerable promise for the elucidation of the bimolecular and photodissociation dynamics of these more complex species. [Pg.881]

A microwave pulse from a tunable oscillator is injected into the cavity by an anteima, and creates a coherent superposition of rotational states. In the absence of collisions, this superposition emits a free-mduction decay signal, which is detected with an anteima-coupled microwave mixer similar to those used in molecular astrophysics. The data are collected in the time domain and Fourier transfomied to yield the spectrum whose bandwidth is detemimed by the quality factor of the cavity. Hence, such instruments are called Fourier transfomi microwave (FTMW) spectrometers (or Flygare-Balle spectrometers, after the inventors). FTMW instruments are extraordinarily sensitive, and can be used to examine a wide range of stable molecules as well as highly transient or reactive species such as hydrogen-bonded or refractory clusters [29, 30]. [Pg.1244]

Molecular beam sample introduction (described in section (Bl.7.2)). followed by the orthogonal extraction of ions, results in improved resolution in TOP instruments over eflfrisive sources. The particles in the molecular beam typically have translational temperatures orthogonal to the beam path of only a few Kelvin. Thus, there is less concern with both the initial velocity of the ions once they are generated and with where in the ion source they are fonned (since the particles are originally confined to the beam path). [Pg.1354]

Time-of-flight mass spectrometers have been used as detectors in a wider variety of experiments tlian any other mass spectrometer. This is especially true of spectroscopic applications, many of which are discussed in this encyclopedia. Unlike the other instruments described in this chapter, the TOP mass spectrometer is usually used for one purpose, to acquire the mass spectrum of a compound. They caimot generally be used for the kinds of ion-molecule chemistry discussed in this chapter, or structural characterization experiments such as collision-induced dissociation. Plowever, they are easily used as detectors for spectroscopic applications such as multi-photoionization (for the spectroscopy of molecular excited states) [38], zero kinetic energy electron spectroscopy [39] (ZEKE, for the precise measurement of ionization energies) and comcidence measurements (such as photoelectron-photoion coincidence spectroscopy [40] for the measurement of ion fragmentation breakdown diagrams). [Pg.1354]

In sunnnary, the SFA is a versatile instrument that represents a unique platfonu for many present and fiiture implementations. Unlike any other experimental teclmique, the SFA yields quantitative insight into molecular dimensions, structures and dynamics under confinement. [Pg.1738]

A completely new method of determining siufaces arises from the enormous developments in electron microscopy. In contrast to the above-mentioned methods where the surfaces were calculated, molecular surfaces can be determined experimentally through new technologies such as electron cryomicroscopy [188]. Here, the molecular surface is limited by the resolution of the experimental instruments. Current methods can reach resolutions down to about 10 A, which allows the visualization of protein structures and secondary structure elements [189]. The advantage of this method is that it can be apphed to derive molecular structures of maaomolecules in the native state. [Pg.129]

Frequently an analyst must select, from several instruments of different design, the one instrument best suited for a particular analysis. In this section we examine some of the different types of instruments used for molecular absorption spectroscopy, emphasizing their advantages and limitations. Methods of sample introduction are also covered in this section. [Pg.388]

The basic design of instrumentation for monitoring molecular fluorescence and molecular phosphorescence is similar to that found for other spectroscopies. The most significant differences are discussed in the following sections. [Pg.427]

Molecular Fluorescence A typical instrumental block diagram for molecular fluorescence is shown in Figure 10.45. In contrast to instruments for absorption spectroscopy, the optical paths for the source and detector are usually positioned at an angle of 90°. [Pg.427]

Molecular Phosphorescence Instrumentation for molecular phosphorescence must discriminate between phosphorescence and fluorescence. Since the lifetime for fluorescence is much shorter than that for phosphorescence, discrimination is easily achieved by incorporating a delay between exciting and measuring phosphorescent emission. A typical instrumental design is shown in Figure 10.46. As shown... [Pg.428]

In principle, emission spectroscopy can be applied to both atoms and molecules. Molecular infrared emission, or blackbody radiation played an important role in the early development of quantum mechanics and has been used for the analysis of hot gases generated by flames and rocket exhausts. Although the availability of FT-IR instrumentation extended the application of IR emission spectroscopy to a wider array of samples, its applications remain limited. For this reason IR emission is not considered further in this text. Molecular UV/Vis emission spectroscopy is of little importance since the thermal energies needed for excitation generally result in the sample s decomposition. [Pg.434]

The evaluation of instrumentation for molecular UV/Vis spectroscopy is reviewed in the following pair of papers. Altermose, 1. R. Evolution of Instrumentation for UV-Visible Spectrophotometry Parti, /. Chem. Educ. 1986, 63, A216-A223. [Pg.458]

The Q in Q/TOF stands for quadrupole (see Chapter 25, Quadrupole Ion Optics ). A Q/TOF instrument — normally used with an electrospray ion inlet — measures mass spectra directly to obtain molecular or quasi-molecular mass information, or it can be switched rapidly to MS/MS mode to examine structural features of ions. The analyzer layout is presented in Figure 20.2. [Pg.153]

In one instrument, ions produced from an atmospheric-pressure ion source can be measured. If these are molecular ions, their relative molecular mass is obtained and often their elemental compositions. Fragment ions can be produced by suitable operation of an APCI inlet to obtain a full mass spectrum for each eluting substrate. The system can be used with the effluent from an LC column or with a solution from a static solution supply. When used with an LC column, any detectors generally used with the LC instrument itself can still be included, as with a UV/visible diode array detector sited in front of the mass spectrometer inlet. [Pg.167]

A single instrument — a hybrid of a quadrupole and a TOF analyzer — can measure a full mass spectrum of ions produced in an ion source. If these are molecular ions, their relative molecular mass is obtained. Alternatively, precursor ions can be selected for MS/MS to give a fragment-ion spectrum characteristic of the precursor ions chosen, which gives structural information about the original molecule. [Pg.173]

In an EW- of a B/E-linked scan using an electric/magnetic-sector instrument, a precursor ion is selected. In this case it is m, which might be a molecular ion but equally could be any fragment ion. All product ions (mj, m3, m4) from decomposition of m, in the first field-free region between the ion source and the ion collector are found, thereby giving connections mpm, m -m3, m -m4. [Pg.241]

Almost any type of analyzer could be used to separate isotopes, so their ratios of abundances can be measured. In practice, the type of analyzer employed will depend on the resolution needed to differentiate among a range of isotopes. When the isotopes are locked into multielement ions, it becomes difficult to separate all of the possible isotopes. For example, an ion of composition CgHijOj will actually consist of many compositions if all of the isotopes ( C, C, H, H, 0, O, and 0) are considered. To resolve all of these isotopic compositions before measurement of their abundances is difficult. For low-molecular-mass ions (HjO, COj) or for atomic ions (Ca, Cl), the problems are not so severe. Therefore, most accurate isotope ratio measurements are made on low-molecular-mass species, and resolution of these even with simple analyzers is not difficult. The most widely used analyzers are based on magnets, quadrupoles, ion traps, and time-of-flight instruments. [Pg.365]


See other pages where Molecular instrumentation is mentioned: [Pg.266]    [Pg.75]    [Pg.75]    [Pg.1]    [Pg.17]    [Pg.266]    [Pg.75]    [Pg.75]    [Pg.1]    [Pg.17]    [Pg.1244]    [Pg.1331]    [Pg.1437]    [Pg.767]    [Pg.388]    [Pg.388]    [Pg.412]    [Pg.424]    [Pg.428]    [Pg.446]    [Pg.3]    [Pg.12]    [Pg.158]    [Pg.185]    [Pg.225]    [Pg.243]    [Pg.244]    [Pg.253]    [Pg.261]    [Pg.278]    [Pg.283]    [Pg.284]   
See also in sourсe #XX -- [ Pg.427 ]