Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Instrumentation scatterer

Fig. 10. Scattered light including ghosts appearing in a single, double, and triple monochromator. Although scattered light plunges to the square root in a double monochromator, interference with Raman spectra still occurs occasionally. In a triple monochromator, instrumental scatter has never been known to interfere with Raman scatter... Fig. 10. Scattered light including ghosts appearing in a single, double, and triple monochromator. Although scattered light plunges to the square root in a double monochromator, interference with Raman spectra still occurs occasionally. In a triple monochromator, instrumental scatter has never been known to interfere with Raman scatter...
Fiq. 20a. The pulsed Raman spectrum of Mn-doped ZnSe single crystal using a detection interval of 200 nsec. Broad band fluorescence superimposed on a large instrumental scattered light component was observed. Recordings taken with ratemeter time constants (TC) of 1 sec and 10 sec are shown (37). [Pg.328]

Here the symbols R, P and G denote respectively the Rayleigh ratio, particle scattering function and instrument scattering reading. It is possible to take other angles such as 60° and 120°, which are also symmetrical about 90°. However, the angles 45° and 135° are most frequently selected, and the widely used Brice-Phoenix photo-... [Pg.178]

The pioneering work of Svedherg and other early researchers, as continued over the years through the application of much improved instrumentation (scattered laser light, electron microscopy, among other methods for investigating microstructure) are described briefly later in this article. [Pg.416]

Several parameters affect the NIR results, for example, are the seeds whole or ground Grinding samples make a nonhomogenous sample more homogenous, which often improves the repeatability and reproducibility of the results. Particle size can affect NIR results, so the shape and distribution of the ground samples are important. This is particularly important for filter instruments in monochromator and FT-NIR instruments, scatter corrections and derivatives can be used to correct for particle size differences. [Pg.132]

See also Fourier Transformation and Sampling Theory PET, Methods and Instrumentation Scattering Theory Statistical Theory of Mass Spectra. [Pg.628]

See also Diffusion Studied Using NMR Spectroscopy Electromagnetic Radiation Fourier Transformation and Sampling Theory Laser Applications in Electronic Spectroscopy Laser Spectroscopy Theory Light Sources and Optics Neutron Diffraction, Instrumentation Scattering Theory. [Pg.907]

Flowever, in order to deliver on its promise and maximize its impact on the broader field of chemistry, the methodology of reaction dynamics must be extended toward more complex reactions involving polyatomic molecules and radicals for which even the primary products may not be known. There certainly have been examples of this notably the crossed molecular beams work by Lee [59] on the reactions of O atoms with a series of hydrocarbons. In such cases the spectroscopy of the products is often too complicated to investigate using laser-based techniques, but the recent marriage of intense syncluotron radiation light sources with state-of-the-art scattering instruments holds considerable promise for the elucidation of the bimolecular and photodissociation dynamics of these more complex species. [Pg.881]

This text covers quantitative analysis by electron energy-loss spectroscopy in the electron microscope along with instrumentation and applicable electron-scattering theory. [Pg.1328]

Figure 10.9 Light-scattering photometers, (a) Schematic top view showing movable photodetector. (Reprinted from Ref. 2, p. 176.) (b) Cutaway photograph of commercial light-scattering instrument, the Brice-Phoenix Universal Scattering Photometer. (Photo courtesy of the Virtis Co., Gardiner, New York.)... Figure 10.9 Light-scattering photometers, (a) Schematic top view showing movable photodetector. (Reprinted from Ref. 2, p. 176.) (b) Cutaway photograph of commercial light-scattering instrument, the Brice-Phoenix Universal Scattering Photometer. (Photo courtesy of the Virtis Co., Gardiner, New York.)...
Photomultipliers are used to measure the intensity of the scattered light. The output is compared to that of a second photocell located in the light trap which measures the intensity of the incident beam. In this way the ratio [J q is measured directly with built-in compensation for any variations in the source. When filters are used for measuring depolarization, their effect on the sensitivity of the photomultiplier and its output must also be considered. Instrument calibration can be accomplished using well-characterized polymer solutions, dispersions of colloidal silica, or opalescent glass as standards. [Pg.692]

The Q and ft) dependence of neutron scattering structure factors contains infonnation on the geometry, amplitudes, and time scales of all the motions in which the scatterers participate that are resolved by the instrument. Motions that are slow relative to the time scale of the measurement give rise to a 8-function elastic peak at ft) = 0, whereas diffusive motions lead to quasielastic broadening of the central peak and vibrational motions attenuate the intensity of the spectrum. It is useful to express the structure factors in a form that permits the contributions from vibrational and diffusive motions to be isolated. Assuming that vibrational and diffusive motions are decoupled, we can write the measured structure factor as... [Pg.479]

Optical measurements permit the quantification of visibility degradation under different conditions. Several instruments are capable of measuring visual air quality, e.g., cameras, photometers, telephotometers, transmis-someters, and scattering instruments. [Pg.208]

Still be smooth, free of fouling material, and the edges sharp and square. It will be diffieult to achieve, but remember the better the instrumentation performs, the less the data scatter that will require rationalization later. [Pg.432]


See other pages where Instrumentation scatterer is mentioned: [Pg.719]    [Pg.166]    [Pg.346]    [Pg.719]    [Pg.166]    [Pg.346]    [Pg.67]    [Pg.68]    [Pg.76]    [Pg.327]    [Pg.873]    [Pg.1165]    [Pg.1200]    [Pg.1308]    [Pg.1313]    [Pg.1338]    [Pg.1385]    [Pg.1623]    [Pg.1625]    [Pg.1689]    [Pg.1806]    [Pg.1807]    [Pg.767]    [Pg.442]    [Pg.446]    [Pg.164]    [Pg.690]    [Pg.318]    [Pg.402]    [Pg.417]    [Pg.766]    [Pg.1662]    [Pg.1827]    [Pg.1827]    [Pg.90]    [Pg.478]    [Pg.478]    [Pg.205]    [Pg.209]    [Pg.38]   
See also in sourсe #XX -- [ Pg.20 ]




SEARCH



HPLC instrumentation evaporative light scattering detector

Inelastic neutron scattering instruments

Instrumentation scattering

Instrumentation, laser Doppler scattering

Instruments dynamic light-scattering

Instruments light-scattering

Instruments neutron scattering

Light scattering instrumentation

Light scattering method instrumentation

Light-scattering instrumentation analysis

Light-scattering instrumentation implementation

Light-scattering instrumentation innovation

Light-scattering instrumentation principles

Light-scattering instrumentation process

Light-scattering instrumentation product development

Light-scattering instrumentation that process

Multiangle light scattering instruments

Raman scattering instrument design

Raman scattering instrumentation

Resonance neutron scattering instruments

Response function, light scattering instrument

Small Angle Neutron Scattering Instruments

Small-angle neutron scattering instrumentation

© 2024 chempedia.info