Micro standards

Requirements for standards used In macro- and microspectrofluorometry differ, depending on whether they are used for Instrument calibration, standardization, or assessment of method accuracy. Specific examples are given of standards for quantum yield, number of quanta, and decay time, and for calibration of Instrument parameters. Including wavelength, spectral responslvlty (determining correction factors for luminescence spectra), stability, and linearity. Differences In requirements for macro- and micro-standards are considered, and specific materials used for each are compared. Pure compounds and matrix-matched standards are listed for standardization and assessment of method accuracy, and existing Standard Reference Materials are discussed. [Pg.98]

The difficulties of working with small quantities of liquids are much greater than with small quantities of solids. For example a competent worker can, and does in fact, often work with 100 mg, of solid without any special apparatus. With liquids this is often not practicable because of the much greater losses entailed, particularly when it is realised that one ordinary-sized drop weighs about 50-100 mg. The account which follows gives details of modifications of standard apparatus suitable for the semi-micro scale defined above. [Pg.59]

Standard Semi-micro Equipment. The authors have found, during many years, that a student provided with the following basic semimicro equipment will be enabled to carry out the majority of the small preparations described in this book. [Pg.71]

To accommodate smaller liquid flows of about 10 pl/min, micro-ultrasonic nebulizers have been designed. Although basically similar in operation to standard ultrasonic nebulizers, in these micro varieties, the end of a very-small-diameter capillary, through which is pumped the sample solution, is in contact with the surface of the transducer. This arrangement produces a thin stream of solution that runs down and across the center of the face of the transducer. The stream of sample... [Pg.148]

ANSI StandardB74.12-1982 (macro sizes) and ANSI StandardB74.10-1977 (K1983) (micro sizes), American National Standards Institute, New York, 1982 and 1977. [Pg.17]

Product particle sizes vary from standard size of 6/14 mesh—U.S. Std. Sieves to mini-size granules of 10/16 mesh—U.S. Std. Sieves for small particle blends, to micro-size granules of 14/35-U.S. Std. Sieves for use on golf course tees and greens. Approximate mm corresponding to mesh sizes are 6 mesh/3.36 mm 10 mesh /2 mm 35 mesh/0.5 mm. [Pg.134]

Currently, there is continuing work on an iadustry standard method for the direct determination of monomer, dimer, and trimer acids. Urea adduction (of the methyl esters) has been suggested as a means of determining monomer ia distilled dimer (74). The method is tedious and the nonadductiag branched-chain monomer is recovered with the polymeric fraction. A micro sublimation procedure was developed as an improvement on urea adduction for estimation of the polymer fraction. Incomplete removal of monomer esters or loss of dimer duriag distillation can lead to error (75). [Pg.116]

Whilst solving some ecological problems of metals micro quantity determination in food products and water physicochemical and physical methods of analysis are employed. Standard mixture models (CO) are necessary for their implementation. The most interesting COs are the ones suitable for graduation and accuracy control in several analysis methods. Therefore the formation of poly functional COs is one of the most contemporary problems of modern analytical chemistry. The organic metal complexes are the most prospective class of CO-based initial substances where P-diketonates are the most appealing. [Pg.405]

Fig. 2. Results of interfacial shear strength measurements of the same fiber/matrix systems using four different micro-mechanical tests during a round-robin program involving 12 different laboratories, (a) Results for untreated, unsized carbon fibers, (b) Results for carbon fibers with the standard level of surface treatment. Redrawn from ref. [13]. Fig. 2. Results of interfacial shear strength measurements of the same fiber/matrix systems using four different micro-mechanical tests during a round-robin program involving 12 different laboratories, (a) Results for untreated, unsized carbon fibers, (b) Results for carbon fibers with the standard level of surface treatment. Redrawn from ref. [13].
The first step in E-cat testing is to bum the carbon off the sample. The sample is then placed in a MAT unit (Figure 3-13), the heart of which is a fixed bed reactor. A certain amount of a standard gas oil feedstock is injected into the hot bed of catalyst. The activity i.s reported as the conversion to 430°F (221°C) material. The feedstock s quality, reactor temperature, catalyst-to-oil ratio, and space velocity are four variables affecting MAT results. Each catalyst vendor uses slightly different operating variables to conduct micro activity testing, as indicated in Table 3-2. [Pg.104]

Under micro-discontinuous chromium coatings, copper undercoats improve corrosion resistance. On non-conductors, especially on plastic substrates, copper is often applied before nickel-chromium plating over the initial electroless copper or nickel deposit in order to improve ductility and adhesion, e.g. as tested by the standard thermal-cycling test methods ... [Pg.517]

Vickers and Knoop Micro Hardness Tests, British Standard 5411 Part 6 1981... [Pg.705]

Procedure. Place 25.0 mL of the thiosulphate solution in the titration cell. Set the applied voltage to zero with respect to the S.C.E. after connecting the rotating platinum micro-electrode to the polarising unit. Adjust the range of the micro-ammeter. Titrate with the standard 0.005 M iodine solution in the usual manner. [Pg.633]

Dilute solutions of antimony(III) and arsenic(III) (ca 0.0005M) may be titrated with standard 0.002 M potassium bromate in a supporting electrolyte of 1M hydrochloric acid containing 0.05 M potassium bromide. The two electrodes are a rotating platinum micro-electrode and an S.C.E. the former is polarised to +0.2 volt. A reversed L-type of titration graph is obtained. [Pg.634]

A more typical application of micro-reticulate resins in exclusion chromatography is shown by the separation of a standard protein mixture depicted in figure 3. [Pg.288]

However, for flow in micro-channels, the wall thickness can be of the same order of channel diameter and will affect the heat transfer significantly. For example, Choi et al. (1991) reported that the average Nusselt numbers in micro-channels were much lower than for standard channels and increased with the Reynolds number. [Pg.38]

Pressure drop and heat transfer in a single-phase incompressible flow. According to conventional theory, continuum-based models for channels should apply as long as the Knudsen number is lower than 0.01. For air at atmospheric pressure, Kn is typically lower than 0.01 for channels with hydraulic diameters greater than 7 pm. From descriptions of much research, it is clear that there is a great amount of variation in the results that have been obtained. It was not clear whether the differences between measured and predicted values were due to determined phenomenon or due to errors and uncertainties in the reported data. The reasons why some experimental investigations of micro-channel flow and heat transfer have discrepancies between standard models and measurements will be discussed in the next chapters. [Pg.91]

Because most applications for micro-channel heat sinks deal with liquids, most of the former studies were focused on micro-channel laminar flows. Several investigators obtained friction factors that were greater than those predicted by the standard theory for conventional size channels, and, as the diameter of the channels decreased, the deviation of the friction factor measurements from theory increased. The early transition to turbulence was also reported. These observations may have been due to the fact that the entrance effects were not appropriately accounted for. Losses from change in tube diameter, bends and tees must be determined and must be considered for any piping between the channel plenums and the pressure transducers. It is necessary to account for the loss coefficients associated with singlephase flow in micro-channels, which are comparable to those for large channels with the same area ratio. [Pg.138]

Bo = q/Gh] Q, where t is the period between successive events, U is the mean velocity of single-phase flow in the micro-channel, Jh is the hydraulic diameter of the channel, q is heat flux, m is mass flux, /zlg is the latent heat of vaporization). The dependence t on Bo can be approximated, with a standard deviation of 16%, by... [Pg.311]


See other pages where Micro standards is mentioned: [Pg.391]    [Pg.391]    [Pg.697]    [Pg.37]    [Pg.57]    [Pg.792]    [Pg.391]    [Pg.391]    [Pg.697]    [Pg.37]    [Pg.57]    [Pg.792]    [Pg.1625]    [Pg.142]    [Pg.242]    [Pg.114]    [Pg.160]    [Pg.300]    [Pg.405]    [Pg.754]    [Pg.275]    [Pg.276]    [Pg.313]    [Pg.503]    [Pg.632]    [Pg.729]    [Pg.730]    [Pg.65]    [Pg.71]    [Pg.442]    [Pg.533]    [Pg.437]    [Pg.90]    [Pg.139]    [Pg.180]    [Pg.187]   
See also in sourсe #XX -- [ Pg.122 , Pg.127 , Pg.130 ]