Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Method transfer experimental

Once the method transfer experimentation is complete, the data are compiled and analyzed, and the final report drafted. The transfer report should indicate whether the transfer was successful and all data recorded and reviewed. The report should indicate the file or location of the raw data. Any deviations to the protocol should be appended to the report. [Pg.437]

With the above functions and empirical correlations, it becomes possible to calculate the overall convective heat transfer coefficient hc by Eqs. (16, 4, and 22-24). Figure 26 shows a plot presented by Lints and Glicksman which compares predictions by this method with experimental data from several different sources. Reasonably good agreement is obtained over a range of bed densities corresponding to approximately 0.5 to 3% volumetric solid concentration. [Pg.195]

To understand the catalytic system under investigation as a whole, we tried to transfer experimental methods and the corresponding/orma/ism from inorganic chemistry (see Chap. 3) and enzyme chemistry to metal catalysis. To get an insight into the... [Pg.48]

McFarland and Bakowski methods bracket experimental values, vapor phase mass transfer coefficients is cited in Section 13.9. [Pg.442]

This is referred to as the 2-level model (6) and was used in the past to understand trends in p with structural modifications of the molecule. With the computational methods and experimental accuracy available today this method is viewed as inadequate although it does serve to illustrate the essential features of molecular structure that control p. In the two level model, px (the component of the tensor along the charge transfer axis) is given by... [Pg.43]

Weller s work [5-7] on the kinetics of ESPT brought out the importance of competition between the rates of deactivation of the excited states and the rates of proton transfer. In cases where the deactivation rates are slow enough for a complete establishment of excited-state equilibrium, fluorimetric titrations provide a method for experimental determinations of pK a. However, it has been realized that for a fairly large number of ESPT molecules, there is a frequent mismatch of pA"f, values obtained from Forster cycle and fluorimetric titrations methods. There are also examples of extended fluorimetric titration curves resulting from low proton availability in the mid-pH region (4-10). Various modifications of the Forster cycle and extensions of Weller s original kinetic considerations have been made from time to time and have been reviewed periodically. Some of the earlier important ones include those by Weller [7] in 1961, Vander Donckt [8] in 1970, Schulman [9] in 1974, and Klopffer [10] in 1977. The review by Ireland and Wyatt [11] contains extensive references of experimental results available in the literature until 1976. [Pg.578]

Comparison of the results of the integral method with experimental results and exact solutions show that the prediction of the heat transfer coefficient with the integral method is satisfactory. [Pg.155]

Unfortunately the theory, when used for data interpretation, is based on many simplifications that are not always valid. The success of the method depends on the significance of the axial dispersion and the interfacial mass transfer and on the accuracy of the description of these effects. A comparative study of different measuring technique by [25] has shown, for the chromatographic method, that experimental uncertainties may lead to significantly broader confidence limits for the diffusion coefficients than for measurements in single pellets in a diffusion cell. [Pg.90]

In summary, as it happens with granular and powder carbons, a proper selection of the CF and the activation method and experimental conditions permits the preparation of ACFs with a tailored pore size distribution, with the additional advantage of their fiber shape and small diameters that allow faster mass transfer rates when compared with conventional ACs. [Pg.436]

The USP definition of robustness equals that of the ICH (3) The robustness of an analytical procedure is a measure of its capacity to remain unaffected by small, but deliberate variations in method parameters and provides an indication of its reliability during normal usage. A robustness test is the experimental setup used to evaluate method robustness. It quantifies the insensitivity of the results for a method transfer to another laboratory or instrument. The ICH guidelines also state that One consequence of the evaluation of robustness should be that a series of system suitability parameters (eg., resolution tests) is established to ensure that the validity of the analytical procedure is maintained whenever used (3). [Pg.15]

In the case that qualification is included in the method transfer, the contract should contain an agreed list of all analytical characteristics to be addressed. Specific criteria for success and failure of qualification experiments should be agreed upon and described in a protocol. Responsibility for the cost of experimental repeats that are caused by suspicious Vaberrant/anomalous results should be clarified. The criteria for defining anomalous results and how they would trigger repeat analysis should be well documented. [Pg.271]

A lot of effort is invested at the beginning of the project in defining the scope of work and expectations for transfer completion. This is best covered in a document defining the scope and goal of the method transfer, the regulatory standard to be applied (e.g., following GLP or not), experimental outline, acceptance criteria for assay performance, and transfer or development summary or report. It is useful to spend some time on such a protocol to reduce the risk of misunderstanding and to assure that expectations from both sides match. [Pg.274]

Impact of Experimental Failures on the Method Transfer Timeline... [Pg.278]

Describe a detailed method of data analysis to determine the coefficient Cl and the powers a and from mass transfer experimental data that is typically correlated in the following manner for streamline flow adjacent to a no-slip interface ... [Pg.355]

The methods of experimental measurement of heat and mass transfer coefficients are summarized in Table 4.8, and resulted mainly from heat and mass transfer investigations in packed beds. Heat transfer techniques are either steady or unsteady state. In steady-state methods, the heat flow is... [Pg.89]

During method development (Chapter 9) and validation (Chapter 10), QCs are used for several purposes including checks on precision and accuracy, lower limit of quantitation (LLOQ), recovery and method robustness and ruggedness (Section 9.8.4), as well as stability studies of various kinds (Sections 10.2.7 and 10.2.8), studies of inter-day validation within a specified laboratory and cross-validations in inter-laboratory method transfer (Section 10.2.11). QC samples are also used during method development to assess the final method prior to validation experimental runs that use QCs for this purpose are often referred to as assay prequalifications or pre-study assay evaluations (PSAE). [Pg.42]

Kinetics of the mass transfer Experimental problems Steady-state voltammetry Characterization of the steady state method Membrane-covered and polymer-coated electrodes Microelectrodes for steady state voltammetry Achievement of the steady state at microelectrodes... [Pg.41]


See other pages where Method transfer experimental is mentioned: [Pg.415]    [Pg.437]    [Pg.163]    [Pg.179]    [Pg.415]    [Pg.437]    [Pg.163]    [Pg.179]    [Pg.358]    [Pg.268]    [Pg.41]    [Pg.21]    [Pg.391]    [Pg.252]    [Pg.731]    [Pg.20]    [Pg.264]    [Pg.379]    [Pg.241]    [Pg.843]    [Pg.22]    [Pg.20]    [Pg.79]    [Pg.15]    [Pg.371]    [Pg.70]    [Pg.1215]    [Pg.278]    [Pg.240]    [Pg.459]    [Pg.19]    [Pg.253]    [Pg.72]    [Pg.795]    [Pg.83]   