A process petrochemical plant producing a synthesis gas high in hydrogen experiences an explosion that results in the destruction of a 1500 cubic foot storage vessel normally held at 50 psig. Unprotected glass windows (i.e., no wire mesh reinforcing, nor tempered) in the plant area 150 feet away from the tank are broken. WTiat pressures were involved ... [Pg.501]

Roads and walkways Concrete, slab, mesh reinforced Thickness, in. Sub-base, in. ... [Pg.806]

The overall conclusion of this research indicates that the tire cord mesh reinforcement can have a positive effect on fatigue life. [Pg.154]

It is believed that the superior strength of the chip form is derived from the ability of the glass fiber mesh reinforcement to distribute the load. [Pg.182]

Although FEP is available as a liquid dispersion, the commonly used material in liquid dispersion coatings are PFA and PVDF. Both materials are used in various ways such as filled or unfilled. T q)ical fillers for PFA are mica flakes. PVDF can be reinforced with fiberglass cloth or carbon fabric for additional permeation protection. T q)ical thicknesses achieved are up to 80 milli-inches (2 mm). PFA coatings are used with wire mesh reinforcment for additional protection from delamination. [Pg.295]

Back channels height is 3 meters its width is also 3 meters. Adopting the bolts which made of steel with thread and the model is q)22 mm x 2000 mm to support the roof The distance between two bolts is 1500 on the vertical, 1100 on the transverse, and they are equipped with mesh reinforcements and ladder beams there is a row of strand anchor cable in the roof, the model of the strand anchor cable is [Pg.48]

Testing program. The properties of the trial mixes in both the fresh and hardened state were determined. Fresh state properties measured were slump and flow parameters and workability when used in conjunction with AR fibre mesh reinforcement. Hardened state properties tested included compressive and flexural strength after 7 days of submersion curing at 26°C. Fresh state properties were measured directly after the mixing was completed. [Pg.134]

Figure 2 Step 3 of thin panel construction - placing alkali-resistant glass fibre mesh reinforcement Results and Discussion... Figure 2 Step 3 of thin panel construction - placing alkali-resistant glass fibre mesh reinforcement Results and Discussion...
M.A. Mansur and M.A. Aziz, Study of bamboo-mesh reinforced cement composites. Int. Cem. Compos. Lightweight Concr. 5(3), 165-171 (1983). [Pg.546]

Application of Mesh Reinforced Mortar for Performance Enhancement of Hollow Clay Tile Infill Walls... [Pg.171]

Application of Mesh Reinforced Mortar for Performance Enhancement.. [Pg.183]

In this study, the performance of the Mesh Reinforced Mortar (MRM) application, which is one of the proposed methods for strengthening of RC structures in the Turkish Seismic Code (2007), was verified using pseudo-dynamic (PsD) tests. In this context, a three-bay, three-story frame in Vi scale was prepared and tested. The earthquake load was applied at each story level by means of servo-controlled actuators. The grotmd motions were synthetically derived from the Diizce city center site specific acceleration spectra. The hollow clay tile (HTC) masonry wall in the mid bay was enhanced with MRM. [Pg.185]

Acun B, Sucuoglu H (2006) Strengthening of masonry infill walls in reinforced concrete frames with wire mesh reinforcement. In 8th national conference on earthquake engineering, San Francisco, paper 1852... [Pg.186]

Thick shotcrete, wire mesh reinforced, facing colored to match exposed rock and rough-screen nished to... [Pg.348]

Kyung, K. H., Meyer, C. (2007) Aramid fiber mesh-reinforced thin sheet response to impact loads, in International Workshop HPFRCC 5, RILEM, Proc.53, W. H. Reinhardt and A. E. Naaman eds pp. 447-53. [Pg.421]

The difference between standard shotcrete reinforcement and steel-fibre-reinforced shotcrete is that the mesh reinforcement should be fixed at a certain distance from the uneven surface of the rock, while the steel-fibre-reinforced shotcrete is laid directly on the rock surface. Hence, additional fixing operations are avoided and there are no void spaces behind the shotcreted layer. Tens of applications are reported mines, road and railway tunnels, slope stabilisation, repair and rehabilitation works, etc., in Europe, North America, Southern Asia and Japan. [Pg.506]

For example, consider Techturf, a rugged, natural turf system for golf courses that is based on a PP-mesh reinforcement from BriAg Industries Ltd., a York-based subsidiary of ICI Plastics. It consists of a sand and fertilizer growing medium held together with 2-... [Pg.879]

Directly impacted concrete members should be reinforced on both sides, with sufficient stirrups. Plane bearing structures should be provided with mesh reinforcement. [Pg.43]

B. Mu and C. Meyer, Flexural behavior of fiber mesh-reinforced concrete with glass aggregate , ACi Mater. J. 99, 2002, 425-434. [Pg.556]

F i bre shotcrete i s parti cu larly effective because the very nature of the appi ication ensures that the fibres are preferentially aligned in two dimensions. It has been shown by Morgan and Mowat [64] that steel fibre shotcrete, for instance, can provide better load-bearing capacity than plain wire mesh-reinforced shotcrete at small deflections, and at least equal capacity at large deflections (Figure 14.13). [Pg.572]