Mass spectrometers accuracy

Isotopic analysis of amino acids containing natural abundance levels of 15N was performed by derivatization, GC separation, on-line combustion and direct analysis of the combustion products by isotope-ratio MS. The N2 gas showed RSD better than 0.1%c for samples larger than 400 pmol and better than 0.5%o for samples larger than 25 pmol. After on-column injection of 2 nmol of each amino acid and delivery of 20% of the combustion products to the mass spectrometer, accuracy was 0.04%e and RSD 0.23%o19. [Pg.1059]

TOF mass spectrometers are very robust and usable with a wide variety of ion sources and inlet systems. Having only simple electrostatic and no magnetic fields, their construction, maintenance, and calibration are usually straightforward. There is no upper theoretical mass limitation all ions can be made to proceed from source to detector. In practice, there is a mass limitation in that it becomes increasingly difficult to discriminate between times of arrival at the detector as the m/z value becomes large. This effect, coupled with the spread in arrival times for any one m/z value, means that discrimination between unit masses becomes difficult at about m/z 3000. At m/z 50,000, overlap of 50 mass units is more typical i.e., mass accuracy is no better than about 50-100 mass... [Pg.191]

A mass spectrometer can measure integer relative mass with high accuracy, but the result is not nearly so informative as measurement of accurate relative mass. An example illustrates the reason. [Pg.271]

Other techniques for mass measurement are available, but they are not as popular as those outlined above. These other methods include mass measurements on a standard substance to calibrate the instrument. The standard is then withdrawn, and the unknown is let into the instrument to obtain a new spectrum that is compared with that of the standard. It is assumed that there are no instrumental variations during this changeover. Generally, this technique is less reliable than when the standard and unknown are in the instrument together. Fourier-transform techniques are used with ion cyclotron mass spectrometers and give excellent mass accuracy at lower mass but not at higher. [Pg.274]

The U.S. Environmental Protection Agency publishes sets of Series Methods that describe procedures for detecting and estimating the quantity of environmentally hazardous substances. There are strict requirements for accuracy, reproducibility, and for calibration of mass spectrometers. [Pg.301]

Accurate, precise isotope ratio measurements are important in a wide variety of applications, including dating, examination of environmental samples, and studies on drug metabolism. The degree of accuracy and precision required necessitates the use of special isotope mass spectrometers, which mostly use thermal ionization or inductively coupled plasma ionization, often together with multiple ion collectors. [Pg.369]

Accurate, precise isotope ratio measurements are used in a variety of applications including dating of artifacts or rocks, studies on drug metabolism, and investigations of environmental issues. Special mass spectrometers are needed for such accuracy and precision. [Pg.426]

One of the important advantages of ICPMS in problem solving is the ability to obtain a semiquantitative analysis of most elements in the periodic table in a few minutes. In addition, sub-ppb detection limits may be achieved using only a small amount of sample. This is possible because the response curve of the mass spectrometer over the relatively small mass range required for elemental analysis may be determined easily under a given set of matrix and instrument conditions. This curve can be used in conjunction with an internal or external standard to quantily within the sample. A recent study has found accuracies of 5—20% for this type of analysis. The shape of the response curve is affected by several factors. These include matrix (particularly organic components), voltages within the ion optics, and the temperature of the interffice. [Pg.630]

Atomic masses calculated in this manner, using data obtained with a mass spectrometer can in principle be precise to seven or eight significant figures. The accuracy of tabulated atomic masses is limited mostly by variations in natural abundances. Sulfur is an interesting case in point. It consists largely of two isotopes, fiS and fgS. The abundance of sulfur-34 varies from about 4.18% in sulfur deposits in Texas and Louisiana to 4.34% in volcanic sulfur from Italy. This leads to an uncertainty of 0.006 amu in the atomic mass of sulfur. [Pg.53]

The double-focusing mass spectrometer consists of both magnetic sector and electrostatic analysers (ESAs), the latter being a device which focuses ions with the same m jz values but differing energies. The extent to which the beams of ions of closely similar m jz ratios overlap is thus reduced so that in many cases they may be separated. This then allows their mjz ratios to be determined with more accuracy and precision and the atomic composition of the ion to be determined. [Pg.59]

Table 5.21 Intra-assay precision and accuracy of theLC-MS-MS determination of Idoxifene using a triple-quadrupole mass spectrometer. Reprinted from J. Chromatogr., B, 757, Comparison between liquid chromatography-time-of-flight mass spectrometry and selected-reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of Idoxifene in human plasma , Zhang, H. and Henion, J., 151-159, Copyright (2001), with permission from Elsevier Science... Table 5.21 Intra-assay precision and accuracy of theLC-MS-MS determination of Idoxifene using a triple-quadrupole mass spectrometer. Reprinted from J. Chromatogr., B, 757, Comparison between liquid chromatography-time-of-flight mass spectrometry and selected-reaction monitoring liquid chromatography-mass spectrometry for quantitative determination of Idoxifene in human plasma , Zhang, H. and Henion, J., 151-159, Copyright (2001), with permission from Elsevier Science...
High-resolution mass spectrometer A mass spectrometer capable of high resolution and measuring m/z ratios with high accuracy to enable the atomic composition of an ion to be determined. [Pg.306]

Mass spectrometers can measure the masses of isotopes and molecules with high accuracy. Scientists use this capability to solve a variety of problems. Mass spectrometers are essential instruments in labora-tories that study topics as varied as drug identification and climatic change. [Pg.161]

The most widespread modem use of mass spectrometers is to identify chemical substances. When a molecule is placed in a mass spectrometer, the electrical discharge strips away one of its electrons. This so-called parent ion has virtually the same mass as the neutral molecule. If the mass of the parent ion is measured with high enough accuracy, the data can provide the molecular formula of the substance. [Pg.162]

Analytical standards are prepared for two purposes for fortifying control matrices to determine the analytical accuracy and for calibrating the response of the analyte in the mass spectrometer detector. The purity of all standards must be verified before preparation of the stock solutions. All standards should be refrigerated (2-10 °C) in clean amber-glass bottles with foil/Tefion-lined screw-caps. The absolute volume of the standard solutions may be varied at the discretion of the analyst, as long as the correct proportions of the solute and solvent are maintained. Calibrate the analytical balance before weighing any analytical standard material for this method. [Pg.371]

Principles and Characteristics Mass spectrometry can provide the accurate mass determination in a direct measurement mode. For a properly calibrated mass spectrometer the mass accuracy should be expected to be good to at least 0.1 Da. Accurate mass measurements can be made at any resolution (resolution matters only when separating masses). For polymer/additive deformulation the nominal molecular weight of an analyte, as determined with an accuracy of 0.1 Da from the mass spectrum, is generally insufficient to characterise the sample, in view of the small mass differences in commercial additives. With the thousands of additives, it is obvious that the same nominal mass often corresponds to quite a number of possible additive types, e.g. NPG dibenzoate, Tinuvin 312, Uvistat 247, Flexricin P-1, isobutylpalmitate and fumaric acid for m = 312 Da see also Table 6.7 for m = 268 Da. Accurate mass measurements are most often made in El mode, since the sensitivity is high, and reference mass peaks are readily available (using various fluorinated reference materials). Accurate mass measurements can also be made in Cl... [Pg.355]

Resolution does not affect the accuracy of the individual accurate mass measurements when no separation problem exists. When performing accurate mass measurements on a given component in a mixture, it may be necessary to raise the resolution of the mass spectrometer wherever possible. Atomic composition mass spectrometry (AC-MS) is a powerful technique for chemical structure identification or confirmation, which requires double-focusing magnetic, Fourier-transform ion-cyclotron resonance (FTICR) or else ToF-MS spectrometers, and use of a suitable reference material. The most common reference materials for accurate mass measurements are perfluorokerosene (PFK), perfluorotetrabutylamine (PFTBA) and decafluorotriph-enylphosphine (DFTPP). One of the difficulties of high-mass MS is the lack of suitable calibration standards. Reference inlets to the ion source facilitate exact mass measurement. When appropriately calibrated, ToF mass... [Pg.356]

Magnetic sector mass spectrometers accelerate ions to more than 100 times the kinetic energy of ions analysed in quadrupole and ion trap mass spectrometers. The higher accelerating voltage contributes to the fact that ion source contamination is less likely to result in degraded sensitivity. This is particularly important for analysis that requires stable quantitative accuracy. [Pg.388]

Different options are available for LC-MS instruments. The vacuum system of a mass spectrometer typically will accept liquid flows in the range of 10-20 p,L min-1. For higher flow-rates it is necessary to modify the vacuum system (TSP interface), to remove the solvent before entry into the ion source (MB interface) or to split the effluent of the column (DLI interface). In the latter case only a small fraction (10-20 iLrnin ) of the total effluent is introduced into the ion source, where the mobile phase provides for chemical ionisation of the sample. The currently available commercial LC-MS systems (Table 7.48) differ widely in characteristics mass spectrometer (QMS, QQQ, QITMS, ToF-MS, B, B-QITMS, QToF-MS), mass range m/z 25000), resolution (up to 5000), mass accuracy (at best <5ppm), scan speed (up to 13000Das-1), interface (usually ESP/ISP and APCI, nanospray, PB, CF-FAB). There is no single LC-MS interface and ionisation mode that is readily suitable for all compounds... [Pg.499]

Lasers have advanced the analytical use of mass spectrometers to characterise additives in polymers, and routine application of MALDI is no longer limited to high molecular masses only. MALDI can now clearly produce isotopically resolved mass spectra of small molecules (<800 Da) in an L-ToF instrument, which can be used successfully for the characterisation of molecules of different chemical classes. High mass resolution with an improvement of mass accuracy to... [Pg.702]

Table I also shows that the main component of the total CO2 evolved, which is determined by GC, is the C02, and the total of the other CO2 isotopes (e.g., 6C02 and 8C02) is about 10 of C02. The low concentrations of the isotopic 8C02 and C02 are still, however, an easily measurable quantity of GC-mass spectrometer. The C02 is used as the standard, because the measurement of relates directly to the quantity of the abundant C02. Its low concentration levels help to improve the measuring accuracy of the other CO2 isotopes, chich are also in low concentration. The moles... Table I also shows that the main component of the total CO2 evolved, which is determined by GC, is the C02, and the total of the other CO2 isotopes (e.g., 6C02 and 8C02) is about 10 of C02. The low concentrations of the isotopic 8C02 and C02 are still, however, an easily measurable quantity of GC-mass spectrometer. The C02 is used as the standard, because the measurement of relates directly to the quantity of the abundant C02. Its low concentration levels help to improve the measuring accuracy of the other CO2 isotopes, chich are also in low concentration. The moles...

See other pages where Mass spectrometers accuracy is mentioned: [Pg.252]    [Pg.277]    [Pg.423]    [Pg.46]    [Pg.529]    [Pg.530]    [Pg.531]    [Pg.615]    [Pg.622]    [Pg.89]    [Pg.267]    [Pg.203]    [Pg.936]    [Pg.58]    [Pg.100]    [Pg.27]    [Pg.280]    [Pg.741]    [Pg.821]    [Pg.354]    [Pg.361]    [Pg.381]    [Pg.394]    [Pg.397]    [Pg.414]    [Pg.511]    [Pg.512]   