Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fourier Transform Technique

Fourier transform techniques in spectroscopy [5-7] that are useful in chemistry include all kinds of spectroscopy, in particular, infrared spectroscopy [8] and Raman spectroscopy [9], mass spectrometry, nuclear magnetic resonance spectroscopy [10], and X-ray crystallography [11], [Pg.435]

Even when for all these techniques the Fourier transform is essential, the experimental techniques and thus the apparatus are completely different. A famous general monograph on Fourier transform techniques has been compiled by Bracewell, one of the pioneers [12], [Pg.435]

Once allowance is made for its apparent surface-selective limitation and its requirement that the electrochemical system under investigation be fast and reversible, EMIRS is a versatile technique that can provide valuable mechanistic information for faradaic and non-faradaic processes. The surface selection rule [57, 58] can act as a double-edged weapon it greatly simplifies the spectrum of an adsorbed species and aids assignment, but it may render a surface electrochemical process invisible to IR. [Pg.42]

An alternative spectroscopic approach is not to disperse polychromatic radiation with a prism or grating but rather to create an interference pattern or interferogram that becomes modified by the presence of an absorbing sample. The interferogram is then manipulated mathematically to yield the absorption spectrum of the sample. [Pg.42]

The interferometer used in most common utility FTIR spectrometers was designed by Michelson in 1891 [78]. Although the phenomenon of the interference of light had been recognised much earlier, Michelson s interferometer allowed the two interfering beams to be well-separated in space so [Pg.42]

The Michelson interferometer consists of two mutually perpendicular plane mirrors, one of which can move along the axis shown in Fig. 37(a) and [Pg.43]

Schematic diagrams of (a) the Michelson interferometer and (b) an FTIR spectrometer. References pp. 74 77 [Pg.43]


Recently. Fourier transform technique allowed the determination in natural abundance of C chemical shifts for some 4-thiazoline-2-thiones. Substituent chemical shifts for methyl and phenyl groups have been collected and discussed (874). For the overcrowded polyalkyl-A-4-thiazoline-2-thiones. the evolution of these chemical shifts furnishes... [Pg.384]

Other types of mass spectrometer may use point, array, or both types of collector. The time-of-flight (TOF) instrument uses a special multichannel plate collector an ion trap can record ion arrivals either sequentially in time or all at once a Fourier-transform ion cyclotron resonance (FTICR) instrument can record ion arrivals in either time or frequency domains which are interconvertible (by the Fourier-transform technique). [Pg.201]

Other techniques for mass measurement are available, but they are not as popular as those outlined above. These other methods include mass measurements on a standard substance to calibrate the instrument. The standard is then withdrawn, and the unknown is let into the instrument to obtain a new spectrum that is compared with that of the standard. It is assumed that there are no instrumental variations during this changeover. Generally, this technique is less reliable than when the standard and unknown are in the instrument together. Fourier-transform techniques are used with ion cyclotron mass spectrometers and give excellent mass accuracy at lower mass but not at higher. [Pg.274]

Fourier transformation techniques in spectroscopy are now quite common—the latest to arrive on the scene is Fourier transform Raman spectroscopy. In Chapter 3 1 have expanded considerably the discussion of these techniques and included Fourier transform Raman spectroscopy for the first time. [Pg.468]

The isotope has a nuclear spin quantum number I and so is potentially useful in nmr experiments (receptivity to nmr detection 17 X 10 that of the proton). The resonance was first observed in 1951 but the low natural abundance i>i S(0.75%) and the quadrupolar broadening of many of the signals has so far restricted the amount of chemically significant work appearing on this rcsonance, However, more results are expected now that pulsed fourier-transform techniques have become generally available. [Pg.662]

As a result of different chemical surroundings the resonance frequency absorption will show definite peaks registered by Fourier transform technique. Compared to an internal standard the intensity of the signals is used for quantitative determination of different phosphorus-containing compounds in a given sample. [Pg.617]

The most notable advance in computational crystallography was the availability of methods for rehning protein structures by least-squares optimization. This developed in a number of laboratories and was made feasible by the implementation of fast Fourier transform techniques [32]. The most widely used system was PROLSQ from the Flendrickson lab [33]. [Pg.287]

Thus, identification of all pairwise, interproton relaxation-contribution terms, py (in s ), for a molecule by factorization from the experimentally measured / , values can provide a unique method for calculating interproton distances, which are readily related to molecular structure and conformation. When the concept of pairwise additivity of the relaxation contributions seems to break down, as with a complex molecule having many interconnecting, relaxation pathways, there are reliable separation techniques, such as deuterium substitution in key positions, and a combination of nonselective and selective relaxation-rates, that may be used to distinguish between pairwise, dipolar interactions. Moreover, with the development of the Fourier-transform technique, and the availability of highly sophisticated, n.m.r. spectrometers, it has become possible to measure, routinely, nonselective and selective relaxation-rates of any resonance that can be clearly resolved in a n.m.r. spectrum. [Pg.127]

In recent years, infrared spectroscopy has been enhanced by the possibility of applying Fourier transform techniques to it. This improved spectroscopic technique, known as Fourier transform infrared spectroscopy (FTIR), is of much greater sensitivity than conventional dispersive IR spectroscopy (Skoog West, 1980). Moreover, use of the Fourier transform technique enables spectra to be recorded extremely rapidly, with scan times of only 0-2 s. Thus it is possible to record spectra of AB cements as they set. By comparison, conventional dispersive IR spectroscopy requires long scan times for each spectrum, and hence is essentially restricted to examining fully-set cements. [Pg.364]

A significant advance was the application of the Fourier transform technique to enhance the signal. The optical arrangement of a Fourier transform infrared (FUR) spectrometer is shown in Fig. 27.37 (Habib and Bockris, 1984). A beam of light from an IR source is directed to a beamsplitter, where part of the beam is transmitted to a... [Pg.504]

In the following sections the most important, and relatively simple, transform pairs will be described. They have been chosen, as they represent those that are routinely applied in physical chemistry. Specifically, they are the functions that form the basis of the Fourier-transform techniques that are currently employed... [Pg.352]

Future development of spectroscopic structure-determination methods will depend on the availability of more powerful photon and particle sources as well as advances in photon and particle detectors. Impressive progress has been made in molecular structure determinations based on advances in computation power and in computational algorithms, such as fast Fourier-transform techniques, for nearly every form of spectroscopy and diffraction analysis. Hajdu and co-work-... [Pg.61]

Most chemists tend to think of infrared (IR) spectroscopy as the only form of vibrational analysis for a molecular entity. In this framework, IR is typically used as an identification assay for various intermediates and final bulk drug products, and also as a quantitative technique for solution-phase studies. Full vibrational analysis of a molecule must also include Raman spectroscopy. Although IR and Raman spectroscopy are complementary techniques, widespread use of the Raman technique in pharmaceutical investigations has been limited. Before the advent of Fourier transform techniques and lasers, experimental difficulties limited the use of Raman spectroscopy. Over the last 20 years a renaissance of the Raman technique has been seen, however, due mainly to instrumentation development. [Pg.60]

NMR has been used comparatively little for quantitative analysis although peak areas are directly proportional to concentration. The principal drawbacks are the expensive instrumentation and a lack of sensitivity. The latter can be improved with the aid of computers to accumulate signals from multiple scans or by using a pulsed (Fourier transform) technique. Relative precision lies in the range 3-8%. [Pg.423]

Give plausible reasons why Fourier transform techniques are used for the infrared region but not the visible and ultraviolet spectral regions. [Pg.162]

The applicability of the ESE envelope modulation technique has been extended by two recent publications115,1161. Merks and de Beer1151 introduced a two-dimensional Fourier transform technique which is able to circumvent blind spots in the one-dimensional Fourier transformed display of ESE envelope modulation spectra, whereas van Ormondt and Nederveen1161 could enhance the resolution of ESE spectroscopy by applying the maximum entropy method for the spectral analysis of the time domain data. [Pg.47]

FTIR is a natural for HPLC in that it (FTIR) is a technique that has been used mostly for liquids. The speed introduced by the Fourier transform technique allows, as was mentioned for GC, the recording of the complete IR spectrum of mixture components as they elute, thus allowing the IR photograph to be taken and interpreted for qualitative analysis. Of course, the mobile phase and its accompanying absorptions are ever present in such a technique and water must be absent if the NaCl windows are used, but IR holds great potential, at least for nonaqueous systems, as a detector for HPLC in the future. [Pg.383]

GW Method for Extended, Periodic Systems with a Mixed Slater-Orbital/Plane-Wave Basis and Fourier Transform Techniques... [Pg.36]

The entire analysis of synchronous detection, or lock-in amplification as it is sometimes called, can be conveniently analyzed by straightforward application of the Fourier transform techniques, transform directory, and convolution theorem developed in Section IV of Chapter 1. [Pg.53]


See other pages where Fourier Transform Technique is mentioned: [Pg.181]    [Pg.1165]    [Pg.468]    [Pg.148]    [Pg.1827]    [Pg.2437]    [Pg.213]    [Pg.904]    [Pg.368]    [Pg.365]    [Pg.23]    [Pg.393]    [Pg.313]    [Pg.272]    [Pg.149]    [Pg.60]    [Pg.15]    [Pg.225]    [Pg.64]    [Pg.45]    [Pg.198]    [Pg.292]    [Pg.140]    [Pg.202]   
See also in sourсe #XX -- [ Pg.274 ]




SEARCH



Advanced Fourier transform techniques

Application of Fourier transform techniques

Experimental techniques Fourier transform infrared

Experimental techniques Fourier transform infrared spectroscopy

FTIR spectra collection technique Fourier transform infrared

Fast Fourier-transform techniques

Fourier Transform Technique vibrational spectroscopy

Fourier transform Raman techniques

Fourier transform data-processing techniques

Fourier transform infrared spectra characterization techniques

Fourier transform infrared spectroscopy sampling techniques

Fourier transform mathematical techniques

Fourier transform technique, pulse

Fourier transform techniques problem)

Fourier transform time-resolved techniques

Fourier-transform infrared sampling techniques

Fourier-transform infrared spectroscopy data-processing techniques

Fourier-transform infrared spectroscopy rapid-scan technique

Fourier-transform infrared spectroscopy time-resolved techniques

Indirect Fourier transform technique

Infrared Fourier transform techniques

Infrared spectroscopy Fourier Transform Technique

Laser desorption - Fourier transform techniques

Raman spectroscopy Fourier Transform technique

Signal processing Fourier transform techniques

The Fourier Transform Technique

The use of pulse-ESR and Fourier Transform Techniques

Time domain measurements Fourier transform technique

Transformation techniques

© 2024 chempedia.info