Magnetic sectors mass

Figure Bl.7.4. Schematic diagram of a reverse geometry (BE) magnetic sector mass spectrometer ion source (1) focusing lens (2) magnetic sector (3) field-free region (4) beam resolving slits (5) electrostatic sector (6) electron multiplier detector (7). Second field-free region components collision cells (8) and beam deflection electrodes (9). Figure Bl.7.4. Schematic diagram of a reverse geometry (BE) magnetic sector mass spectrometer ion source (1) focusing lens (2) magnetic sector (3) field-free region (4) beam resolving slits (5) electrostatic sector (6) electron multiplier detector (7). Second field-free region components collision cells (8) and beam deflection electrodes (9).
Figure Bl.7.5. (a) MIKE spectrum of the iinimoleciilar decomposition of 1-butene ions (m/z 56). This spectrum was obtained in the second field-free region of a reverse geometry magnetic sector mass... Figure Bl.7.5. (a) MIKE spectrum of the iinimoleciilar decomposition of 1-butene ions (m/z 56). This spectrum was obtained in the second field-free region of a reverse geometry magnetic sector mass...
Some Factors Important in Choosing between Quadrupole and Magnetic-Sector Mass Spectrometers... [Pg.186]

Linked Scanning and Metastable Ions in Magnetic-Sector Mass Spectrometry... [Pg.237]

Peak matching can be done on quadrupole and magnetic-sector mass spectrometers, but only the latter, particularly as double-focusing instruments, have sufficiently high resolution for the technique to be useful at high mass. [Pg.274]

The ion optics of a magnetic-sector mass spectrometer cause the ion beam leaving the ion source to arrive at a collector after being separated into individual m/z values and focused. [Pg.405]

Fig. 1. Schematic diagram of a double-focusing Nier-Johnson magnetic sector mass spectrometer where ( " ) represents paths of ions having slightly... Fig. 1. Schematic diagram of a double-focusing Nier-Johnson magnetic sector mass spectrometer where ( " ) represents paths of ions having slightly...
Secondary Ion Mass Spectrometry Dynamic Secondary Ion Mass Spectrometry Static Secondary Ion Mass Spectrometry SIMS using a Quadruple Mass Spectrometer SIMS usii a Magnetic Sector Mass Spectrometer See Magnetic SIMS... [Pg.768]

The direct imaging magnetic sector mass analyzer (Fig. 3.19) has the unique property that all parts (lenses, electrostatic analyzer and magnetic sector field) of the secondary ion optics are stigmatic (comparable with light microscopes). This means that all points of the surface are simultaneously projected into the analyzer. [Pg.111]

Tandem quadrupole and magnetic-sector mass spectrometers as well as FT-ICR and ion trap instruments have been employed in MS/MS experiments involving precursor/product/neutral relationships. Fragmentation can be the result of a metastable decomposition or collision-induced dissociation (CID). The purpose of this type of instrumentation is to identify, qualitatively or quantitatively, specific compounds contained in complex mixtures. This method provides high sensitivity and high specificity. The instrumentation commonly applied in GC/MS is discussed under the MS/MS Instrumentation heading, which appears earlier in this chapter. [Pg.17]

Reactions of D with D20 and of 0 with 02, N20, and N02 have been studied with a magnetic sector mass spectrometer. Competition between electron transfer and ion-atom interchange has been observed in the production of 02 by reaction of 0 with 02, an endothermic reaction. The negative ion of the reacting neutral molecule is formed in 02, N2Of and N02 but not in D20. Rate constants have been estimated as a function of repeller potential. [Pg.34]

Choi MS, Francois R, Sims K, Bacon MP, Brown-Leger S, Fleer AP, Ball L, Schneider D, Pichat S (2001) Rapid determination of °Th and Pa in seawater by desolved micro-nebulization Inductively Coupled Plasma magnetic sector mass spectrometiy. Mar Chem 76 99-112... [Pg.55]

Walder AJ, Freedman PA (1992) Isotopic ratio measurement using a double focusing magnetic sector mass analyser with an inductively coupled plasma as an ion somce. J Anal At Spectrom 7 571-575... [Pg.59]

Generally FAB produces protonated, MH+, or depro-tonated, (M — H) , quasi-molecular ions with a little excess energy which will sometimes produce fragment ions of low intensity. FAB is therefore a mild to soft ionisation technique which produces primarily molecular weight information and some structural information. Positive and negative ionisation mass spectra are produced with equal facility. FAB was originally used with magnetic sector mass spectrometers, but lately mainly with quadrupole mass spectrometers (Table 6.10). [Pg.368]

Thermospray ionisation sources are usually outfitted with a quadrupole or magnetic sector mass spectrometer (including hybrids or tandem forms). Thermospray operation allows a reversed-phase solvent system, e.g. a 50 50 (v/v) water-methanol or acetonitrile mix containing 0.1 M ammonium acetate. This ensures compatibility with the universal HPLC procedures available in many industrial research laboratories. [Pg.377]

Magnetic sector mass spectrometers accelerate ions to more than 100 times the kinetic energy of ions analysed in quadrupole and ion trap mass spectrometers. The higher accelerating voltage contributes to the fact that ion source contamination is less likely to result in degraded sensitivity. This is particularly important for analysis that requires stable quantitative accuracy. [Pg.388]

The main characteristics of sector mass spectrometers are shown in Table 6.29. Magnetic sector mass spectrometers are often considered more difficult to operate than QMS and ToF-MS the high-voltage source is more demanding to chromatographic interfacing. For figures of merit, see Table 6.27. [Pg.388]

Applications Sector instruments are applied for niche applications such as high-resolution measurements and fundamental ion chemistry studies. Magnetic sector mass spectrometers remain the instrument of choice in areas of target compound trace analysis, accurate mass measurement and isotope ratio measurement. [Pg.388]


See other pages where Magnetic sectors mass is mentioned: [Pg.1332]    [Pg.1334]    [Pg.1336]    [Pg.157]    [Pg.177]    [Pg.183]    [Pg.255]    [Pg.264]    [Pg.542]    [Pg.547]    [Pg.612]    [Pg.612]    [Pg.612]    [Pg.631]    [Pg.410]    [Pg.58]    [Pg.100]    [Pg.36]    [Pg.242]    [Pg.998]    [Pg.1004]    [Pg.353]    [Pg.361]    [Pg.388]    [Pg.396]    [Pg.656]   


SEARCH



Chemical magnetic sector mass spectrometer

Double-focusing magnetic sector mass analyzer

Glow discharge mass spectrometry magnetic sector

Laser Ablation Cluster Source with a Magnetic Sector Mass Selector at the University of California, Santa Barbara

Magnetic Sector Mass Analysers

Magnetic sector

Magnetic sector field mass spectrometer

Magnetic sector inductively coupled plasma mass

Magnetic sector inductively coupled plasma mass spectrometry , determination

Magnetic sector mass analyzer method

Magnetic sector mass analyzer technology

Magnetic sector mass analyzer with electron ionization

Magnetic sector mass selector

Magnetic sector mass spectrometers

Magnetic sector mass spectrometers Mattauch-Herzog geometry

Magnetic sector mass spectrometers double-focusing

Magnetic sector mass spectrometers electrostatic analyzer

Magnetic sector mass spectrometers linked scans

Magnetic sector mass spectrometers performance characteristics

Magnetic sector mass spectrometers principle

Magnetic sectors mass spectrometric

Magnetic-Sector Tandem Mass Spectrometers

Magnetic-sector mass spectrometry, linked scanning

Mass Spectrometry of Small Molecules Magnetic-Sector Instruments

Mass Spectrometry of Small Molecules Magnetic-Sector nstruments

Mass analysis magnetic sector

Mass analyzer magnetic sector

Mass analyzers, electrostatic magnetic sector

Mass spectrometer magnetic/electric-sector

Mass spectrometers, isotopic analyses magnetic sector

Mass spectrometry analyzers magnetic/electric sector

Mass spectrometry magnetic sector instruments

Mass spectrometry magnetic-sector

Sector

Sectorization

The Magnetic Sector Mass Analyzer

The Magnetic Sector Mass Spectrometer

© 2024 chempedia.info