Fast-Atom Bombardment (FAB) and Liquid-Phase Secondary Ion Mass Spectrometry (LSIMS) Ionization... [Pg.17]

A big step forward came with the discovery that bombardment of a liquid target surface by abeam of fast atoms caused continuous desorption of ions that were characteristic of the liquid. Where this liquid consisted of a sample substance dissolved in a solvent of low volatility (a matrix), both positive and negative molecular or quasi-molecular ions characteristic of the sample were produced. The process quickly became known by the acronym FAB (fast-atom bombardment) and for its then-fabulous results on substances that had hitherto proved intractable. Later, it was found that a primary incident beam of fast ions could be used instead, and a more generally descriptive term, LSIMS (liquid secondary ion mass spectrometry) has come into use. However, note that purists still regard and refer to both FAB and LSIMS as simply facets of the original SIMS. In practice, any of the acronyms can be used, but FAB and LSIMS are more descriptive when referring to the primary atom or ion beam. [Pg.17]

The basic principles of fast-atom bombardment (FAB) and liquid-phase secondary ion mass spectrometry (LSIMS) are discussed only briefly here because a fuller description appears in Chapter 4. This chapter focuses on the use of FAB/LSIMS as part of an interface between a liquid chromatograph (LC) and a mass spectrometer (MS), although some theory is presented. [Pg.81]

FAB has evolved, and fast atoms are being replaced by fast ions, such as cesium (Cs+). This variation is called liquid secondary ion mass spectrometry (LSIMS) because the sample solution affords the secondary ion beam while the bombarding ions constitute the primary beam. Spectra... [Pg.287]

Historically, the term SIMS was developed for bombardment of solid surfaces with ions, so, for greater descriptive precision, the name liquid secondary ion mass spectrometry (LSIMS) is better and can be used synonymously with FAB,... [Pg.386]

The term liquid secondary ion mass spectrometry (LSIMS) is sometimes used synonymously with FAB and is preferred by some as being more descriptive, since FAB could apply to bombardment of solid or liquid surfaces and does not indicate the types of secondaries investigated. In practice, little confusion is likely to result from using either term. Strictly, LSIMS can refer to the use of fast ions (FIB). [Pg.394]

LSIMS. liquid-phase secondary ion mass spectrometry... [Pg.446]

Mass Spectrometry. Mass spectrometry holds great promise for low-level toxin detection. Previous studies employed electron impact (El), desorption chemical ionization (DCI), fast atom bombardment (FAB), and cesium ion liquid secondary ion mass spectrometry (LSIMS) to generate positive or negative ion mass spectra (15-17, 21-23). Firm detection limits have yet to be reported for the brevetoxins. Preliminary results from our laboratory demonstrated that levels as low as 500 ng PbTx-2 or PbTx-3 were detected by using ammonia DCI and scans of 500-1000 amu (unpublished data). We expect significant improvement by manipulation of the DCI conditions and selected monitoring of the molecular ion or the ammonia adduction. [Pg.177]

Fast atom bombardment (FAB) Plasma desorption (PD) Liquid secondary-ion mass spectrometry (LSIMS) Thermospray (TSP)/plasmaspray (PSP) Electrohydrodynamic ionisation (EHI) Multiphoton ionisation (MPI) Atmospheric pressure chemical ionisation (APCI) Electrospray ionisation (ESI) Ion spray (ISP) Matrix-assisted laser desorption/ionisation (MALDI) Atmospheric pressure photoionisation (APPI) Triple quadrupole (QQQ) Four sector (EBEB) Hybrid (EBQQ) Hybrid (EB-ToF, Q-ToF) Tandem ToF-ToF Photomultiplier... [Pg.352]

LSIMS is a more suitable ionisation technique than FD for analysis of mixtures by means of tandem mass spectrometry, because of the higher ion currents generated from polymer additives using LSIMS. LSIMS/MS experiments may be used in conjunction with FD-MS as a screen to determine class, molecular weight and structure of mixtures of organic polymer additives. [Pg.372]

Sample preparation for the common desorption/ionisation (DI) methods varies greatly. Films of solid inorganic or organic samples may be analysed with DI mass spectrometry, but sample preparation as a solution for LSIMS and FAB is far more common. The sample molecules are dissolved in a low-vapour-pressure liquid solvent - usually glycerol or nitrobenzyl alcohol. Other solvents have also been used for more specialised applications. Key requirements for the solvent matrix are sample solubility, low solvent volatility and muted acid - base or redox reactivity. In FAB and LSIMS, the special art of sample preparation in the selection of a solvent matrix, and then manipulation of the mass spectral data afterwards to minimise its contribution, still predominates. Incident particles in FAB and LSIMS are generated in filament ionisation sources or plasma discharge sources. [Pg.384]

Lang SR, Staudenmann W, James P, Manz HJ, Kessler R, Galli B, Moser HP, Rummelt A, Merkle HP (1996) Proteolysis of human calcitonin in excised bovine nasal mucosa elucidation of the metabolic pathway by liquid secondary ionization mass spectrometry (LSIMS) and matrix assisted laser desorption ionization mass spectrometry (MALDI). Pharm Res 13 1679-1685. [Pg.133]

The principle of FAB, less frequently referred to as liquid secondary ionization mass spectrometry (LSIMS), is very similar to secondary-ion mass spectrometry (SIMS). However, FAB utilizes a liquid matrix, such as glycerol, in which a sample is dissolved. The matrix is used to enhance sensitivity and ion current stability. [Pg.509]

Fast-atom bombardment (FAB) and liquid secondary-ion mass spectrometry (LSIMS) methods make up the category of the particle bombardment ionization. In both methods the analyte is dissolved in a liquid such as glycerol, thioglycerol, m-nitrobenzyl alcohol, or diethanolamine and about 1 1 is placed on a... [Pg.713]

In FAB, the sample is usually dispersed in a non-volatile liquid matrix, such as glycerol or diethanolamine, and deposited at the end of a sample probe that can be inserted into the ion source. The sample on the probe is ionised when bombarded by the fast atom beam. However, ionisation of the matrix also occurs, leading to a very large background signal. The technique is thus limited for the analysis of small molecules. Fast-moving ions (Cs+ or Ar+) can be used instead of fast-moving atoms, which is the basis of a technique called liquid secondary ion mass spectrometry (LSIMS). [Pg.310]


See other pages where LSIMS spectrometry is mentioned: [Pg.155]    [Pg.16]    [Pg.372]    [Pg.404]    [Pg.405]    [Pg.411]    [Pg.531]    [Pg.538]    [Pg.542]    [Pg.735]    [Pg.756]    [Pg.7]    [Pg.13]    [Pg.12]    [Pg.381]    [Pg.383]    [Pg.73]    [Pg.184]    [Pg.215]    [Pg.152]    [Pg.728]    [Pg.730]   


SEARCH



Fast Atom Bombardment (FAB) and Liquid-matrix Secondary Ion Mass Spectrometry (LSIMS)

Fast atom bombardment (FAB) and liquid secondary ion mass spectrometry (LSIMS)

LSIMS

Liquid secondary ion mass spectrometry LSIMS)

Mass Spectrometry Basics LSIMS

© 2024 chempedia.info