Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Limiting Transients

In addition to the above, capacitors are many times overlooked and unless their dielectric punch-through voltage for transients is known, limiting transients to 1.5 times the DC working voltage is recommended. [Pg.113]

Test grouting was conducted in accordance with predetermined criteria not to exceed an extreme limiting transient grout pressure of... [Pg.394]

The behavior of such a system is easy to predict in the absence of mobile ions. Ohmic contacts and a high resistivity bulk give rise to a bulk-controlled or space-charge limited currents (L3). A complete analysis of the space-charge limited transient current in insulating crystals has been given (14)- The analysis in polymers is modified by the presence of mobile ionic impurities in two ways. First, in thermal equilibrium the bulk ion and electron concentrations must be... [Pg.179]

The Au-PI-Al samples are no longer symmetric. The observed behavior is consistent with electron injection at the Al-PI contact but not at the Au-PI contact. The increase in work function in Au over A1 implies a less effective electron injector. When the A1 is biased negatively, a peaked space-charge limited transient is observed, and when the Au is biased negatively, the transient has no peak. [Pg.188]

When the cathode is A1 a peak is observed in the transient, but not when the cathode is Au. This observation is consistent with a space-charge limited transient due to electron injection from the smaller work-function A1 electrode. [Pg.189]

G. Denault, M. Mirkin, and A. J. Bard [/. Electroanai Chem., 308, 27 (1991)] suggested that by normalizing the diffusion-limited transient current, /, obtained at an ultramicroelectrode at short times, by the steady-state current, one can determine the diffusion coefficient, Z), without knowledge of the number electrons involved in the electrode reaction, n, or the bulk concentration of the reactant, C. ... [Pg.225]

A surge protection device is a device intended to limit transient over-voltages, and to divert damaging surge currents away from sensitive equipment. [Pg.239]

Section 534 of the lET Regulations contains the requirements for the installation of surge protective devices (SPDs) to limit transient over-voltages where required by section 443 of BS 7671 2008 or where specified by the designer. [Pg.239]

The most limiting transients are determined by conservative analyses which maximize mass and energy additions to the RCS. In addition, the RCS is assumed to be in a water-solid condition at the time of the transient such a condition has been noticed to exist infrequently during plant operation since the operator is instructed to avoid water-solid conditions whenever possible. [Pg.54]

For transients that may be DNB limited, the radial peaking factor is important. The radial peaking factor increases with decreasing power level due to control rod insertion. This increase in FAH is included in the core limits. Transients that may be DNB limited are assumed to begin with an FAH, consistent with the initial power level defined in the Technical Specifications (see Chapter 16 of Reference 5.6). [Pg.124]

The limiting transient states are emergency shutdowns or rapid shutdowns. During these transient conditions, the sodium temperature at the core outlet falls rapidly (DT = 130°C at 20°C/s). Moreover, depending on operating choices, the primary flow rate can also vary. When these transients occur, two problems must be examined ... [Pg.362]

ABSTRACT The method based on the results of the joint model linking a semi-Markov modelling of the system operation process with a multistate approach to system reliability and the linear programming are proposed to the operation and reliability optimization of complex technical systems at the variable operation conditions. The method consists in determining the optimal values of limit transient probabilities at the system operation states that maximize the system lifetimes in the reliability state subsets. The proposed method is applied to the operation and reliability optimization of the port grain transportation system composed of three multistate non-homogeneous series-parallel subsystems linked in series, changing its reliability structure and its components reliability parameters at variable operation conditions. [Pg.385]

Finally, after making the inverse to (4) substitution, we get the optimal limit transient probabilities... [Pg.386]

Replacing in (3) given in (Kolowrocki Soszyhska-Budny 2014), the limit transient probabilities Pi, of the system operation process at the operation states by their optimal values maximizing the mean value //(r) of the system lifetime in the reliability states subset r,r -i-1,..., z) defined by (1) and the mean values Mj, of the unconditional sojourn times at the operation states by their corresponding unknown optimal values we get the system of equations... [Pg.387]

Further, the limit transient probabilities p t) can be approximately obtained using the formula... [Pg.2101]


See other pages where Limiting Transients is mentioned: [Pg.222]    [Pg.184]    [Pg.184]    [Pg.123]    [Pg.115]    [Pg.109]    [Pg.211]    [Pg.27]    [Pg.53]    [Pg.54]    [Pg.54]    [Pg.14]    [Pg.261]    [Pg.374]    [Pg.2101]   


SEARCH



Transient flows of Gaussian networks in the GT limit

Transient limitations

© 2024 chempedia.info