Level of concentration

Few populations, however, meet the conditions for a true binomial distribution. Real populations normally contain more than two types of particles, with the analyte present at several levels of concentration. Nevertheless, many well-mixed populations, in which the population s composition is homogeneous on the scale at which we sample, approximate binomial sampling statistics. Under these conditions the following relationship between the mass of a randomly collected grab sample, m, and the percent relative standard deviation for sampling, R, is often valid. ... [Pg.188]

This low level of concentration is typical of free-radical polymerizations. Next we inquire how long it will take the free-radical concentration to reach 0.99[M-]5, liter" in this case. Let a = (16fk jkj [1] q) ... [Pg.363]

Experiments on the scale of 1 to 1 are often used to study the local ventilation around an operator s workplace. Tracer gas is used to simulate the contaminant transport, and a high concentration level of the model tracer gas makes it possible to work with a convenient level of concentration for the measurements. Figure 12.31 shows an enclosure with an emission source S and a laboratory. setup with a model source 5,. The dimensionless concentration c/cg is... [Pg.1185]

CR = cooling range, °F, difFerence between hot water into tower and cold water from the tower, °F B = rate of blow-down, gpm. (Because an acceptable level of concentration has usually been predetermined, the operator is more concerned with the amount of blowdown necessary to maintain the concentration. Equation 9-132.)... [Pg.395]

Magnesium salts exhibit properties similar to those of calcium, except that they generally are slightly more soluble and normally are present in MU water sources at a lower level of concentration, so that the overall scaling and deposition effect of magnesium salts is lessened. [Pg.224]

From his conductivity measurements on solutions, Arrhenius concluded that strong electrolytes are not exceptions. Instead they dissociate into ions. When z = 2, it meant that each solute species dissociated to give two ions. A compound with Z = 3 dissociated to give three ions. Moreover, interpreting the results of his experiments at varying levels of concentration, Arrhenius concluded that at sufficiently high dilution, every electrolyte becomes fully dissociated. [Pg.1225]

If you decide to study for several hours at once, take short breaks of five or ten minutes every half hour or so. You will find that this method maintains a higher overall level of concentration. [Pg.4]

The analytical value (e.g. the concentration) that corresponds to the critical value. The limit of decision is of minor importance in analytical chemistry because the detection at this level of concentration succeeds only in 50% of all cases. [Pg.315]

The accuracy of a method should be assessed using a minimum of nine determinations conducted over a minimum range of three concentration levels (80%, 100%, and 120% of the target concentration) [37]. Experience from our laboratory has showed that by using at least five levels of concentrations in duplicate (i.e., 80%, 90%i, 100%i, 110%, and 120% of the target concentration), a better result can be achieved. For dissolution studies, the accuracy of the required profile should be tested at 40%, 75%, and 110% of the theoretical release) [20],... [Pg.252]

The validation process begun in Phase I is extended during Phase II. In this phase, selectivity is investigated using various batches of drugs, available impurities, excipients, and samples from stability studies. Accuracy should be determined using at least three levels of concentration, and the intermediate precision and the quantitation limit should be tested. For quality assurance evaluation of the analysis results, control charts can be used, such as the Shewart-charts, the R-charts, or the Cusum-charts. In this phase, the analytical method is refined for routine use. [Pg.257]

Dewhurst R J, Fisher W J, Tweed IKS and Wilkins R J (2003), Comparison of grass and legume silages for milk production. 1. Production responses with different levels of concentrates , Journal of Dairy Science, 86, 2598-2611. [Pg.113]

Although the neutron activation analysis is inherently more sensitive than the atomic absorption spectrometry, both procedures yield a reliable measurement of vanadium in seawater at the natural levels of concentration. [Pg.232]

Total or partial ion suppression is a well-known LC-MS effect, which is induced by coeluting matrix components that can have a dramatic effect on the intensity of the analyte signal. As can be observed in Fig. 1, analyte suppression occurs as a consequence of the different matrix interferences present in waste-water samples, making the identification and/or quantification process difficult or unfeasible. Even when working under selection ion monitoring (SIM) conditions, these matrix effects can cause ion suppression in the detection of some analytes that are present at low levels of concentration, as seen in this figure. Several papers have reported this effect [30-32] and different alternatives to overcome these problems, such as the inclusion of a size-exclusion step [33] or sequential SPE [28], have been applied for the determination of pesticides in... [Pg.57]

Fig-1 SPE-LC-ESI-MS analysis (SIM mode) of two wastewater samples, spiked at different levels of concentration. Compounds (1) ciromazine, (2) oxamil, (3) metomil, (4) carbendazime, (5) thiabendazole, (6) imidacloprid, (7) acetamiprid, (8) thiacloprid... [Pg.58]

The mass balance may be carried out at any level of concentration within the zone to give ... [Pg.1018]

Internal standardization circumvents the effects of time-variant instrument response, but does not compensate for different ionization efficiencies of analyte and standard. For internal standardization, a compound exhibiting close similarity in terms of ionization efficiency and retention time is added to the sample at a known level of concentration, e.g., an isomer eluting closely to the analyte or a homologue may serve for that purpose. It is important to add the standard before any clean-up procedure in order not to alter the concentration of the analyte without affecting that of the standard. For reliable results, the relative concentration of analyte and standard should not differ by more than a factor of about ten. [Pg.480]

Witherup S, Cleveland FP, Shaffer FE, et al. 1955. The physiological effects of the introduction of heptachlor into the diet of experimental animals in varying levels of concentration Report of Experiment No. 2. U.S. Environmental Protection Agency, Freedom of Information Office, MRID No. 00062599. [Pg.148]

The phosphate manufacturing and phosphate fertilizer industry includes the production of elemental phosphorus, various phosphorus-derived chemicals, phosphate fertilizer chemicals, and other nonfertilizer phosphate chemicals [1-30], Chemicals that are derived from phosphorus include phosphoric acid (dry process), phosphorus pentoxide, phosphorus penta-sulfide, phosphoms trichloride, phosphorus oxychloride, sodium tripolyphosphate, and calcium phosphates [8]. The nonfertilizer phosphate production part of the industry includes defluori-nated phosphate rock, defluorinated phosphoric acid, and sodium phosphate salts. The phosphate fertilizer segment of the industry produces the primary phosphorus nutrient source for the agricultural industry and for other applications of chemical fertilization. Many of these fertilizer products are toxic to aquatic life at certain levels of concentration, and many are also hazardous to human life and health when contact is made in a concentrated form. [Pg.399]

Pulse-radiolysis experiments allow an examination of the first steps in the decay of radical-cations. Solutions of the radical-cation in the region of 10 M are generated. Bimolecular reactions between species at this level of concentration proceed relatively slowly and this simplifies interpretation of the experimental data. Particularly, electron transfer between radical-cations and radical species derived from them is not observed during the experiment. [Pg.189]

If you want to add pure antifreeze to what s in your radiator right now, to increase the concentration, you have to take some of the mixture out of the radiator, first. The radiator holds only so much fluid. So, an even more interesting problem involves removing a certain amount of what s in the radiator now and replacing it with pure antifreeze to achieve the level of concentration that you want. [Pg.190]

The Problem A man has a 16-quart radiator that now contains 16 quarts of 20 percent antifreeze. How much of the current mixture has to be removed and replaced with pure antifreeze to raise the level of concentration to 35 percent ... [Pg.190]

Replicates of six samples per each level of concentration were prepared for each compound. Each standard was prepared and titrated immediately. The data sets of end-point volumes and milligrams of the standards were treated statistically, where the standard deviations and regression analysis were performed. [Pg.126]

Six filters for each level of concentration were spiked using variable volume pipettes. The following volumes 13, 25, 50, 100, and 200 yL of the 10 mg/mL solution yielded 0.13, 0.25, 0.50, 1.00 and 2.00 mg of sodium dichloroisocyanurate dihydrate on a filter, respectively. When the filter was dry, the "filter extraction" section was followed. The end-point volumes were converted to milligrams from the calibration curve and the percent recoveries were calculated. [Pg.127]


See other pages where Level of concentration is mentioned: [Pg.193]    [Pg.391]    [Pg.2042]    [Pg.156]    [Pg.480]    [Pg.166]    [Pg.480]    [Pg.80]    [Pg.42]    [Pg.116]    [Pg.63]    [Pg.212]    [Pg.396]    [Pg.116]    [Pg.366]    [Pg.63]    [Pg.262]    [Pg.1]    [Pg.6]    [Pg.312]    [Pg.378]    [Pg.470]    [Pg.683]    [Pg.195]    [Pg.272]    [Pg.193]    [Pg.196]    [Pg.248]   
See also in sourсe #XX -- [ Pg.164 , Pg.165 ]