Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Laser improved model

An improved model of a laser) In the simple laser model considered in Section 3.3, we wrote an algebraic equation relating N, the number of excited atoms, to n, the number of 1 aser photons. In more realistic models, this would be replaced by a differential equation. For instance, Milonni and Eberly (1988) show that after certain reasonable approximations, quantum mechanics leads to the system... [Pg.81]

Calculating the exact response of a semiconductor heterostructure to an ultrafast laser pulse poses a daunting challenge. Fortunately, several approximate methods have been developed that encompass most of the dominant physical effects. In this work a model Hamiltonian approach is adopted to make contact with previous advances in quantum control theory. This method can be systematically improved to obtain agreement with existing experimental results. One of the main goals of this research is to evaluate the validity of the model, and to discover the conditions under which it can be reliably applied. [Pg.251]

In the field of DNA sequencing instruments, Perkin-Elmer [26] switched from the PMT-based model 373 sequencer to the CCD-based model 377, which allowed the simultaneous discrimination of four or more colors in emission, in a single lane of an electrophoretic gel. The CCD made possible the use of a specific fluorescent label for each type of base and throughput was improved more than four times [27], Excitation uses an argon laser. [Pg.100]

The present research has treated important parts of the modeling of combustion and NOx formation in a biomass grate furnace. All parts resulted in useful approaches. For all these approaches successful first steps were taken. Currently, more research is underway to obtain improved results NH3 production is measured in the grid reactor with the tunable diode laser, detailed kinetics will be attached to the front propagation model, including the measured NH3 release functionalities, and for the turbulent combustion model heat losses are taken into account. In addition, the fuel layer model has to be coupled to the turbulent combustion model in the furnace. [Pg.180]

Compact and stable devices are available that take advantage of the improved quality of the crystal lasers, as well as increased pump efficiencies. Hundreds of different models of Nd + based lasers have demonstrated laser action (Kaminskii, 1981). It is possible to operate these Nd + solid state lasers in the continuous regime, with output powers ranging from 1 W to 1000 W. Pulsed operation is also possible, with a pulse length from the picosecond range, via mode-locking, to tens of nanoseconds by Q-switch operation. [Pg.63]

In some cases the measured V-V transfer rates differ from theoretical predictions, which indicates that some improvement is needed in theoretical models. Sophisticated computer analysis has to be employed to transform the experimental data to theoretical parameters The spectroscopic studies of cw and pulsed chemical lasers including the local variation of laser output on different vibration-rotation transitions as a function of distance froih the injectory array has been a useful tool, too, for elucidating the different reaction paths and the excited molecular levels involved... [Pg.83]

In this reciew the attempt is made to exhibit some of the possibilities of laser applications in modem spectroscopy. The rapid development of new laser types and the improvement of the existing models lend lasers steadily increasing importance as spectroscopic light sources, and it seems that the laser revolution is only just beginning. These laser developments lead in different directions ... [Pg.84]

Focused X-ray beam (at Beam Line 15A) was used for this study. In order to improve the resolution, the focused beam (about 1 x 1.5 mm) was cut into 0.9-0.5 mm O by apertures which were set just in front of the cell. Modulation frequency was 10 Hz. Scanning X-Y stage which was originally developed for the laser microscopy was set perpendicular to the surface of the iron-base table and scanning and data acquisition were controlled by PC-9801 VM2 microcomputer (NEC Co. Ltd.) with the original program Various size and shape of metal foils were glued on the paper to have a model patterned sample. [Pg.156]

The technology of Low Level Laser Therapy (LLLT) was introduced into clinical medicine more than three decades ago. This form of treatment has great appeal due to its novelty, ease in use, relatively cost-efficient and low morbidity profile [5], LLLT has been shown to improve remarkably the process of wound healing in humans [5-8] and animal models [9-11], In vitro studies demonstrated that LLLT has a stimulating effect on cell mitosis [12] and proliferation and migration of fibroblasts [13], keratinocytes [14, 15] and endothelial cells [16], LLLT enhances NO secretion [17] and cytokine production [18, 19] and may lead to increased dermal angiogenesis [20],... [Pg.264]


See other pages where Laser improved model is mentioned: [Pg.211]    [Pg.214]    [Pg.288]    [Pg.289]    [Pg.216]    [Pg.152]    [Pg.379]    [Pg.252]    [Pg.115]    [Pg.187]    [Pg.194]    [Pg.117]    [Pg.22]    [Pg.433]    [Pg.146]    [Pg.48]    [Pg.210]    [Pg.221]    [Pg.105]    [Pg.641]    [Pg.303]    [Pg.287]    [Pg.220]    [Pg.352]    [Pg.362]    [Pg.32]    [Pg.87]    [Pg.697]    [Pg.344]    [Pg.346]    [Pg.377]    [Pg.452]    [Pg.113]    [Pg.154]    [Pg.344]    [Pg.506]    [Pg.259]    [Pg.715]    [Pg.39]    [Pg.107]    [Pg.179]   
See also in sourсe #XX -- [ Pg.81 , Pg.286 ]




SEARCH



© 2024 chempedia.info