Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Internal volume

The systems of such type have been developed of all last 10 years. We shall bring some characteristics of one of the last development within the framework of European BRITE project, carried out in LETT This 3D cone-beam tomograph is referred to as EVA Bench or Equipment for Voludensimetry Analysis. It is oriented on NDT of industrial products from ceramics and other composites. One of the main task of this tomograph is achievement of high resolution at study of whole internal volume of researched object. For test sample of the size 10mm spatial resolution in 50mm was obtained [14]. [Pg.217]

Figure 9.14 Calibration curve for GPC as log M versus the retention volume Vj, showing how the location of the detector signal can be used to evaluate M. Also shown are the void volume Vy and the internal volume Vj in relation to Vj, and KVj as a fraction of Vj. Figure 9.14 Calibration curve for GPC as log M versus the retention volume Vj, showing how the location of the detector signal can be used to evaluate M. Also shown are the void volume Vy and the internal volume Vj in relation to Vj, and KVj as a fraction of Vj.
Progressively smaller molecules have access to successively larger fractions of the internal volume. Therefore, as Vj emerges, consecutive fractions of the polymer come with it. Thus we can write the retention volume for a particular molecule weight fraction as... [Pg.647]

Fig. 8. Internal volume (FQ that is accessible to sugars as functions of the cotton molecular diameters (33). (a) Batting A, greige , scoured—bleached , caustic mercerized H, Hquid ammonia treated, (b) Fabric 0> scoured—bleached V> cross-linked. Fig. 8. Internal volume (FQ that is accessible to sugars as functions of the cotton molecular diameters (33). (a) Batting A, greige , scoured—bleached , caustic mercerized H, Hquid ammonia treated, (b) Fabric 0> scoured—bleached V> cross-linked.
Scouting and bleaching slightly increase the accessible internal volume, Hquid ammonia treatment of the scoured—bleached cotton decreases it slightly, caustic mercerization substantially enhances accessibiHty, and cross-linking to impart durable press properties reduces this accessible internal pore volume substantially. [Pg.314]

Another important fac tor is the tendency of product prices to faU as the total national or international volume or produc tion increases. Sales prices may faU by 20 percent for a doubling in volume or produc tion. [Pg.817]

Pi = absolute pressure in vessel at failure Po = ambient pressure outside vessel V = internal volume of vessel 7 = ratio of specific heats... [Pg.225]

Each SynChropak column is tested chromatographically to assure that it has been packed according to specifications. For SynChropak GPC columns, a mixture of a high molecular weight DNA and glycyltyrosine, a dipeptide, is used to evaluate internal volume and efficiency. The mobile phase used for the test is 0.1 M potassium phosphate, pH 7, and the flow rate is 0.5 ml/min for 4.6-mm i.d. columns. Minimum plate count values and operational flow rates are listed in Table 10.4 for 4.6-mm i.d. columns of all supports and the various diameters of the SynChropak GPC 100 columns. [Pg.314]

The internal volume of the casing string above the float collar is Internal volume = 13,800(0.2086)... [Pg.1210]

For the analyses given in Table 1, samples were contained in special polyethylene vials specifically designed to fit the Kaman Nuclear dual-axis rotator assembly. These vials are 4,5cm long and 1.0cm o.d. with an internal volume of 2.3cu cm. When filled, a vial contains approx 0,5g of NC and 2.3g of TNT or HMX. [Pg.358]

Globular proteins are compact, are roughly spherical or ovoid in shape, and have axial ratios (the ratio of their shortest to longest dimensions) of not over 3. Most enzymes are globular proteins, whose large internal volume provides ample space in which to construct cavities of the specific shape, charge, and hy-drophobicity or hydrophilicity required to bind substrates and promote catalysis. By contrast, many structural proteins adopt highly extended conformations. These fibrous proteins possess axial ratios of 10 or more. [Pg.30]

Here the phenomenon of capillary pore condensation comes into play. The adsorption on an infinitely extended, microporous material is described by the Type I isotherm of Fig. 5.20. Here the plateau measures the internal volume of the micropores. For mesoporous materials, one will first observe the filling of a monolayer at relatively low pressures, as in a Type II isotherm, followed by build up of multilayers until capillary condensation sets in and puts a limit to the amount of gas that can be accommodated in the material. Removal of the gas from the pores will show a hysteresis effect the gas leaves the pores at lower equilibrium pressures than at which it entered, because capillary forces have to be overcome. This Type IV isotherm. [Pg.188]

Although it is unclear at present how the public authorities would react if micro reactors were largely employed for production purposes, it stands to reason that in principle faster approval could be achieved in this way Approval is often connected with assigning the equipment under consideration to certain reactor categories which typically are defined, among other features, by the reactor internal volume. [Pg.54]

Das Chemidabor im Mikrochip, Blick durch die Wirtschafi, December 1997 Chemtel glass chip of Orchid Biocomputer, Princeton 144 cells for parallel processing matchbox-sized system with many devices micro pumps with no movable parts 10 nl internal volume carrying out of different reactions in parallel fashion complete chemistry laboratory en miniature 10 000 cells as future-development task [223],... [Pg.89]

The above-mentioned targets refer to general advantages of micro reactors [42, 80, 100, 114, 119]. Enhanced transfer and better controlled residence time improve conversion and selectivity. The tools have small internal volumes, allowing one to generate flexibly a multitude of samples in serial or parallel fashion. Synthesis can be combined with a multi-step procedure. The economy of micro-reactor processes has not really been analyzed so far however, it is clear that as laboratory tools they allow in a number of cases technical expenditure, personnel and costs to be reduced. [Pg.475]

Following the arguments given above, micro mixers are valuable tools for bench-scale continuous processing to fill the recycle loop. For first tests on feasibility, the total volume of the recycle loop has to be kept small, demanding also for small-scale processing units. Conventional devices would probably suffer here from too large internal volumes. [Pg.483]

MIMOS II has three temperature sensors one on the electronics board and two on the SH. One temperature sensor in the SH is mounted near the internal reference absorber, and the measured temperature is associated with the reference absorber and the internal volume of the SH. The other sensor is mounted outside the SH at the contact ring assembly. It gives the approximate analysis temperature for the sample on the Martian surface. This temperature is used to route the Mossbauer data to the different temperature intervals (maximum of 13, with the temperature width software selectable) assigned in memory areas. Shown in Fig. 3.21 are the data of the three temperature sensors taken on Mars (rover Opportunity at Meridiani Planum) in January 2004 between 12 10 PM on Sol 10 (10 Martian days after landing) and 11 30 AM on Sol 11. The temperature of the electronics board inside the rover is much higher than the temperatures inside the SH and the contact plate sensor, which are nearly identical and at ambient Martian temperature. [Pg.62]

MIMOS II has three temperature sensors, one on the electronics board and two on the sensor head. One temperature sensor in the sensor head is mounted near the internal reference absorber, and the measured temperature is associated with the reference absorber and the internal volume of the sensor head. The other sensor is mounted outside the sensor head at the contact ring assembly. It gives the analysis temperature for the sample on the Martian surface. This temperature is used to route... [Pg.449]

A model of blending aqueous salt buffers for chromatography has been developed.1 The model assumed full miscibility, low mixing enthalpy and low volume change. It reproduced experimental S-curves of buffer strength produced by a Pharmacia P3500 dual piston system equipped with a model 24 V dynamic mixer with 0.6 mL internal volume as well as those produced by a BioSepra ProSys 4-piston system equipped with two dynamic mixers of 1.2 mL internal volume. [Pg.129]


See other pages where Internal volume is mentioned: [Pg.9]    [Pg.138]    [Pg.647]    [Pg.207]    [Pg.282]    [Pg.461]    [Pg.381]    [Pg.531]    [Pg.242]    [Pg.221]    [Pg.767]    [Pg.899]    [Pg.84]    [Pg.143]    [Pg.396]    [Pg.421]    [Pg.26]    [Pg.466]    [Pg.1210]    [Pg.1002]    [Pg.208]    [Pg.533]    [Pg.188]    [Pg.188]    [Pg.125]    [Pg.178]    [Pg.8]    [Pg.54]    [Pg.292]    [Pg.495]    [Pg.138]    [Pg.337]   
See also in sourсe #XX -- [ Pg.205 ]

See also in sourсe #XX -- [ Pg.172 ]




SEARCH