Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Installation water tanks

A series of tests were performed at the AFC s National Reactor Testing Station in Idaho, starting in 1953. The reactor was situated outdoors, and was operated remotely. The core of the first version had fuel assembhes of aluminum and enriched uranium plates of the Materials Testing Reactor (MTR) type, installed in a water tank. One of the five control rods could be ejected downward and out of the core by spring action upon intermption of a magnet... [Pg.217]

Internal cathodic protection of water tanks and boilers is most economical if it is taken care of at the design stage. It can, however, be installed at a later stage as a rehabilitation measure to halt the progress of corrosion. Tanks and boilers in ships were described in Section 17.4. Further applications of internal protection are dealt with in Chapter 21. [Pg.441]

The electrolysis protection process using impressed current aluminum anodes allows uncoated and hot-dipped galvanized ferrous materials in domestic installations to be protected from corrosion. If impressed current aluminum anodes are installed in water tanks, the pipework is protected by the formation of a film without affecting the potability of the water. With domestic galvanized steel pipes, a marked retardation of the cathodic partial reaction occurs [15]. Electrolytic treatment alters the electrolytic characteristics of the water, as well as internal cathodic protection of the tank and its inserts (e.g., heating elements). The pipe protection relies on colloidal chemical processes and is applied only to new installations and not to old ones already attacked by corrosion. [Pg.456]

Further chapters cover in detail the characteristics and applications of galvanic anodes and of cathodic protection rectifiers, including specialized instruments for stray current protection and impressed current anodes. The fields of application discussed are buried pipelines storage tanks tank farms telephone, power and gas-pressurized cables ships harbor installations and the internal protection of water tanks and industrial plants. A separate chapter deals with the problems of high-tension effects on pipelines and cables. A study of costs and economic factors concludes the discussion. The appendix contains those tables and mathematical derivations which appeared appropriate for practical purposes and for rounding off the subject. [Pg.583]

On-off two-position with differential gap Slow Any Any Large-capacity temperature and level installations. Storage tanks, hot-water supply tanks, room heating, compressor suction scmbber... [Pg.293]

Cold-water tanks made from Polythene or GRP are generally available, especially in domestic sizes, and are now often used in domestic installations. [Pg.60]

Another way to reduce consumption is to install a pressure reducer ahead of the DI water tanks. This will also reduce wear on DI water valves. [Pg.89]

Figure 185 shows an office building equipped with stratified water tank. The deep water tank is installed in unused space of the building. The volume of tank is 375 m3 that can store 3,500 kWh of cold heat with a 90 kW heat pump chiller. Inside of the water tank, an apparatus, which decreases inlet velocity of water is installed. [Pg.336]

NFPA 22—Standard for Water Tanks For Private Fire Protection NFPA 24—Standard for the Installation of Private Fire Service Mains and Their Appurtenances... [Pg.351]

The irnportant question to answer at this point is whether we need to be concerned about the critical radius of insulation when insulating hot-water pipes or even hr -water tanks. Should we always check and make sure that the outer radius of insulation sufficiently exceeds the critical radius before we install any insulation Probably not, as explained here. [Pg.176]

Uol-water tank insulation kits consisting of 3-cm thick fiberglass insulation k = 0.035 V/m °C) large enough to wrap the entire tank are available in the market for about 30. If such an insulation is installed on this water tank by the home owner himself, how long will it take for thi.s additional insulation to pay for itself Anstrers.-17.5 percent, 1.5 years... [Pg.219]

Ideally, a plant of this size is started up in stages, so that replacement will be a continuous process. Membranes in all the 10 packs of a press are generally renewed at the same time. A reserve of 10 assembled packs can be kept in a water tank for immediate installation. If necessary, a single pack in a press can be renewed at any time, although this complicates the maintenance schedule. The reserve press on the plant, which could serve either stage I or stage II, was used when a press was being serviced. [Pg.149]

Figure 1. Fuel Cell Test Installation a) fuel processor 1- system of hot desulphurization, 2 — reactor, 3 - water tank, 4-feed water supply, 5 - steam generator, 6 — synthesis gas cooler, 7 - drop separator b) circuit of reformer with hot desulphurization c) circuit of coal steam gasifier with hot desulphurization... Figure 1. Fuel Cell Test Installation a) fuel processor 1- system of hot desulphurization, 2 — reactor, 3 - water tank, 4-feed water supply, 5 - steam generator, 6 — synthesis gas cooler, 7 - drop separator b) circuit of reformer with hot desulphurization c) circuit of coal steam gasifier with hot desulphurization...
Install the bottom water tank. This is in the form of a shallow tray about 1/2 meter deep resting on the floor and extending to the wall. A hole in one side of it joins to the water pump pipe. The water in this tank is not under pressure. [Pg.268]

Install the beams over the pile which rest on the wall and are to support the shield and upper water tank. [Pg.268]

Install the upper water tank sides and water mains and connections. [Pg.269]

The tubes or liners 46 are set in place and the shield sections are sealed together so lhai they represent a continuous gas tight disc except for ihe sa. ety, control, and uranium rod openings. Sealed to the siiielJ, a.nd extending outwardly and downwardly from it, there is placed the thin metal gas cover which exlencis over the ciusivie oC the concrete wall. The upper water tank. sides and water mains and connections are then installed, and the control and safety rod placed in their receptacles, connected to... [Pg.682]

The bottom water tank is then installed. A hole in... [Pg.682]

The total flume length should be not less than 19 times the maximum weir head, Weir plate shall be installed not less than 1.6 times the maximum weir head away from the water tank that the overflow water tongue will not spread immediately after weir. [Pg.83]

Pock marks Air bubbles adhering to pipe in flotation tank Improper adjustment of spray rings that surround water tank Install wiper in tank Readjust spray rings... [Pg.167]

Water supply for important units shall be from more than one source, as well as from a dedicated water tank installed at a height. [Pg.98]

The dedicated water tank is generally an overhead tank which is always kept full by an independent source of water. It is connected to the safety showers and eyewash fountains. These shall be installed in areas where strong corrosive acids, alkalies, and other chemicals are being handled. [Pg.104]

In hard or moderately hard waters, galvanised steel hot-water tanks, with galvanised circulating pipes and cast-iron boilers, usually give trouble-free service, but failure by pitting occurs occasionally. Sometimes this is due to extraneous causes, such as rubbish left inside the tank when it is installed. Iron filings left in the bottom of the tank or deposits of inert material are liable to interfere with the formation of the protective scale by the water, and can lead to failure. [Pg.88]


See other pages where Installation water tanks is mentioned: [Pg.446]    [Pg.459]    [Pg.823]    [Pg.57]    [Pg.59]    [Pg.60]    [Pg.790]    [Pg.221]    [Pg.79]    [Pg.478]    [Pg.477]    [Pg.105]    [Pg.478]    [Pg.105]    [Pg.3]    [Pg.22]    [Pg.116]    [Pg.165]    [Pg.221]    [Pg.404]    [Pg.82]    [Pg.343]    [Pg.57]    [Pg.33]    [Pg.343]    [Pg.86]   
See also in sourсe #XX -- [ Pg.336 ]




SEARCH



Tank installations

Water tanks

© 2024 chempedia.info