Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Inside storage

Vapour space inside storage tank Storage tank outside buildings... [Pg.401]

Embrittlement of service materials. The low temperatures inside storage tanks and transmission pipelines may cause significant susceptibleness of the structural material in vibrations and shocks. Mild steel and most iron alloys, at LH2 temperatures, lose their ductility being liable to increased risk of mechanical failure [50]. [Pg.551]

There are empirically determined design criteria for designing ventilation systems for flammable materials inside storage and process areas. These design criteria are given in Table 7-6. [Pg.341]

Materials, particularly combustibles, or equipment placed inside storage tank dikes. [Pg.39]

The dry cool meal is conveyed from the DC to outside the solvent extraction plant for size reduction and then on to meal storage. It is important to properly dry and cool the meal to prevent continued evaporative cooling in storage or transport, which will cause reduced flowability, solidification, and bridging of the meal inside storage and transport vessels. [Pg.2503]

Inside storage systems, primarily concrete silos and metal bins, are used for storing soybeans at elevators and plant sites. Sometimes a shortage of available protected storage at peak harvest time exists. Unlike storing cottonseed in dry regions (e.g., west Texas) or corn in the Midwest, soybeans are rarely and for only very short periods stored on concrete pads without protection against the weather. [Pg.350]

STORAGE Handle and store under nitrogen outside or detached storage is preferred, inside storage should be in a standard flammable liquids storage warehouse, room or cabinet. [Pg.5]

DISPOSAL AND STORAGE METHODS absorb on vermiculite and bum in open in cinerator addition of KMn04 will break down to acid, which can be routed to sewage treatmen plant outside storage preferred inside storage should be in a standard flammable liquids storag room or cabinet separate from oxidizing materials, peroxides, acids, and alkalies. [Pg.392]

DISPOSAL AND STORAGE METHODS manage whatever cannot be saved for recovery or recycling in an appropriate and approved waste disposal facility dispose of container and unused contents in accordance with federal, state and local requirements store in a cool, dry, well-ventilated location outside storage is preferred inside storage should be in a standard flammable liquid storage room or cabinet use explosion-proof electrical equipment and lighting ... [Pg.457]

DISPOSAL AND STORAGE METHODS absorb liquid in sand or inert absorbent, and place in a secured sanitary landfill atomize large quantities in a suitable combustion chamber equipped with an appropriate effluent gas cleaning device store in a cool, dry location use only with adequate ventilation keep in the dark store only if stabilized outside storage is preferred inside storage should be in a standard flammable liquids storage room or cabinet separate from strong oxidants, alkalies, food and feedstuffs. [Pg.522]

Insulin is a polypeptide containing SI amino acid.s arranged in two chains (A and Bl linked by disulphide bridges. A precursor, called proinsulin, is hydrolysed inside storage granules to fonn insulin and a residual C-peptide. The granules store insulin as crystals containing zinc and insulin. [Pg.79]

Ethylene oxide is stored in an outside cool area below 30°C (86°E), provided with a water-spray system, and isolated from combustible materials such as acids, bases, chlorides, oxides, and metallic potassium. Protect against physical damage. Avoid inside storage. Shipping should be done in steel cylinders, drums, and insulated tank cars. [Pg.361]

The inside storage of more than 2,000 standard cubic ft. (scf) of flammable gas, or more than 300 pounds of liquefied petroleum gas requires a separate room, compartment, or special storage building. [Pg.196]

CFR1910.106(d)(4)(v) 4.4.20 Dispensing in inside storage rooms shall be by approved pump or self-closing faucet only. [Pg.216]

The OSHA requirements for inside storage rooms for chemicals are given in 29 CFR Part 1910.1 06(d)(4) and are based onNFPA Standard 30-1969. This latter standard has been amended since 1969, but at this time, the OSHA requirements have not been changed to... [Pg.194]

The amount of flammable and combustible liquids permitted in inside storage rooms depends upon the type of construction and whether an automatic fire suppression system is installed or not. The permissible amounts under both the OSHA and more recent NFPA standards are the same and are given in Table 3.11. [Pg.194]


See other pages where Inside storage is mentioned: [Pg.1935]    [Pg.918]    [Pg.401]    [Pg.285]    [Pg.342]    [Pg.342]    [Pg.1693]    [Pg.220]    [Pg.537]    [Pg.580]    [Pg.668]    [Pg.693]    [Pg.729]    [Pg.820]    [Pg.984]    [Pg.1939]    [Pg.200]    [Pg.196]    [Pg.438]    [Pg.194]   
See also in sourсe #XX -- [ Pg.246 ]




SEARCH



Inside

© 2024 chempedia.info