In the cathodic protection of storage tanks, potentials should be measured in at least three places, i.e., at each end and at the top of the cover [16]. Widely different polarized areas arise due to the small distance which is normally the case between the impressed current anodes and the tank. Since such tanks are often buried under asphalt, it is recommended that permanent reference electrodes or fixed measuring points (plastic tubes under valve boxes) be installed. These should be located in areas not easily accessible to the cathodic protection current, for example between two tanks or between the tank wall and foundations. Since storage tanks usually have several anodes located near the tank, equalizing currents can flow between the differently loaded anodes on switching off the protection system and thus falsify the potential measurement. In such cases the anodes should be separated. [Pg.100]

Further chapters cover in detail the characteristics and applications of galvanic anodes and of cathodic protection rectifiers, including specialized instruments for stray current protection and impressed current anodes. The fields of application discussed are buried pipelines storage tanks tank farms telephone, power and gas-pressurized cables ships harbor installations and the internal protection of water tanks and industrial plants. A separate chapter deals with the problems of high-tension effects on pipelines and cables. A study of costs and economic factors concludes the discussion. The appendix contains those tables and mathematical derivations which appeared appropriate for practical purposes and for rounding off the subject. [Pg.583]

Examples of cathodic protection with impressed current are, at the present time, protection of steel pipelines in maritime environments or in subsoil. An important example of anodic protection is in the storage of acids in steel tanks—the anodic current passivates the steel (see Fig. 16.1a). [Pg.365]

Cathodic protection has many applications, e.g. in refineries, power stations, gas, water, and oil utilities on marine structures, e.g. jetties, piers, locks, offshore platforms, pipelines, ships hulls, etc. and on land structures, e.g. buried pipeline, storage tanks, cables, etc. For each use, the cathodic protection system requires careful design, either impressed current, sacrificial anodes, or a combination of both may be chosen. There may also be other protection systems, e.g. paint, the nature of which will affect the design parameters and must be taken into consideration. [Pg.273]

Metallurgical and Inspection Requirements for Cast Sacrificial Anodes for Offshore Applications Impressed Current Cathodic Protection of Internal Submerged Surfaces of Steel Water Storage Tanks... [Pg.859]