Identification wavelength

Additions to the PLM include monochromatic filters or a monochromator to obtain dispersion data (eg, the variation in refractive index with wavelength). By the middle of the twentieth century, ultraviolet and infrared radiation were used to increase the identification parameters. In 1995 the FTIR microscope gives a view of the sample and an infrared absorption pattern on selected 100-p.m areas (about 2—5-ng samples) (37). [Pg.334]

Many sources of energy are used to excite samples to emit characteristic wavelengths for chemical identification and assay (91,92). Very high temperature sources can be employed but are not necessary. AH materials can be vaporized and excited with temperatures of only a few electron volts. The introduction of samples to be analyzed into high temperature or high density plasmas and thek uniform excitation often are problematic. [Pg.114]

Polarimetry. Polarimetry, or polarization, is defined as the measure of the optical rotation of the plane of polarized light as it passes through a solution. Specific rotation [ a] is expressed as [cr] = OcjIc where (X is the direct or observed rotation, /is the length in dm of the tube containing the solution, and c is the concentration in g/mL. Specific rotation depends on temperature and wavelength of measurement, and is a characteristic of each sugar it may be used for identification (7). [Pg.9]

The X-ray emission process followii the excitation is the same in all three cases, as it is also for the electron-induced X-ray emission methods (EDS and EMPA) described in Chapter 3. The electron core hole produced by the excitation is filled by an electron falling from a shallower level, the excess energy produced being released as an emitted X ray with a wavelength characteristic of the atomic energy levels involved. Thus elemental identification is provided and quantification can be obtained from intensities. The practical differences between the techniques come from the consequences of using the different excitation sources. [Pg.335]

The characteristic lines observed in the absorption (and emission) spectra of nearly isolated atoms and ions due to transitions between quantum levels are extremely sharp. As a result, their wavelengths (photon energies) can be determined with great accuracy. The lines are characteristic of a particular atom or ion and can be used for identification purposes. Molecular spectra, while usually less sharp than atomic spectra, are also relatively sharp. Positions of spectral lines can be determined with sufficient accuracy to verify the electronic structure of the molecules. [Pg.386]

As one dilutes the amount of an element in an arc, the number of lines observable is reduced, and ultimately there remain only a few lines of the element which is diluted. These lines are referred to in Section 20.2 as the raies ultimes or persistent lines and tables of their wavelengths may be found in chemical handbooks. The identification of these lines will permit detection of elements present in low concentration, and all qualitative methods utilise the persistent lines. [Pg.766]

A further aid to identification comes from the fact that a molecule commonly has complex series of absorptions spanning a range of wavelengths. This fingerprint region of the spectrum may be too difficult to analyze in detail, but its presence enables us to recognize the substance by comparing the spectrum to an atlas of spectra. [Pg.217]

As is well known the difficulty of analysis of a sample increases as its complexity increases. Analysis usually commences with a rather nonspecific clean-up step and requires that the separation step that follows be highly selective and depends on a detection step that is as specific as possible. As the selectivity of detection increases there is also an increase in the reliability of the identification and it is possible to reduce the demands made on the selectivity of the preceding separation method. This is the case for radiometric and enzymatic methods and also explains the popularity of fluorescence measurements. The latter obtain their selectivity from the freedom to choose excitation and measurement wavelengths. [Pg.36]

The maximum absorption wavelengths in different solvents of many carotenoids can be found in the literature, and the % III/II values are also available for some carotenoids. It is common to find variations of 1 to 3 nm in for the same carotenoid in the same solvent cited in different publications. No identification based simply on the matching of recorded UV-Vis spectra with tabulated data can be done without considering the relationships of structures and the factors influencing light absorption. The principal factors that influence carotenoid UV-Vis absorption spectra are discussed below. [Pg.464]

The identification of synthetic colorants (pure or mixtures) in foods is usually carried out using spectrophotometry but the resolution of complex mixtures in food requires a previous separation of extract components by SPE and chromatographic techifiques. Dual wavelength, solid phase, and derivative spectrophotometric methods combined with chemometric approaches have been used. ... [Pg.539]

The identification and quantification of potentially cytotoxic carbonyl compounds (e.g. aldehydes such as pentanal, hexanal, traw-2-octenal and 4-hydroxy-/mAW-2-nonenal, and ketones such as propan- and hexan-2-ones) also serves as a useful marker of the oxidative deterioration of PUFAs in isolated biological samples and chemical model systems. One method developed utilizes HPLC coupled with spectrophotometric detection and involves precolumn derivatization of peroxidized PUFA-derived aldehydes and alternative carbonyl compounds with 2,4-DNPH followed by separation of the resulting chromophoric 2,4-dinitrophenylhydrazones on a reversed-phase column and spectrophotometric detection at a wavelength of378 nm. This method has a relatively high level of sensitivity, and has been successfully applied to the analysis of such products in rat hepatocytes and rat liver microsomal suspensions stimulated with carbon tetrachloride or ADP-iron complexes (Poli etui., 1985). [Pg.16]

Polar or thermally labile compounds - many of the more modern pesticides fall into one or other of these categories - are not amenable to GC and therefore LC becomes the separation technique of choice. HPLC columns may be linked to a diode-array detector (DAD) or fluorescence detector if the target analyte(s) contain chromophores or fluorophores. When using a DAD, identification of the analyte(s) is based on the relative retention time and absorption wavelengths. Similarly, with fluorescence detection, retention time and emission and absorption wavelengths are used for identification purposes. Both can be subject to interference caused by co-extractives present in the sample extract(s) and therefore unequivocal confirmation of identity is seldom possible. [Pg.742]

Tables 15 and 16 show the absorption maxima of some metal complexes of benzothiazolyl-substituted formazans 230 and 231.283 The wavelengths are metal ion dependent, making formazans useful reagents for the identification of specific metal ions or the simultaneous determination of two ions. The wavelengths are much longer than those of the formazan anion (Table 14). The general trend for electron-rich substituents is toward a larger shift this is to be expected as it tends to enhance the aromatic character of the ring and increase the covalent character of the metal — nitrogen bond. The sharpness of the absorption band has been attributed to coordination to the heterocyclic nitrogen as in 232.57S... Tables 15 and 16 show the absorption maxima of some metal complexes of benzothiazolyl-substituted formazans 230 and 231.283 The wavelengths are metal ion dependent, making formazans useful reagents for the identification of specific metal ions or the simultaneous determination of two ions. The wavelengths are much longer than those of the formazan anion (Table 14). The general trend for electron-rich substituents is toward a larger shift this is to be expected as it tends to enhance the aromatic character of the ring and increase the covalent character of the metal — nitrogen bond. The sharpness of the absorption band has been attributed to coordination to the heterocyclic nitrogen as in 232.57S...

See other pages where Identification wavelength is mentioned: [Pg.73]    [Pg.73]    [Pg.263]    [Pg.54]    [Pg.873]    [Pg.285]    [Pg.293]    [Pg.293]    [Pg.201]    [Pg.334]    [Pg.52]    [Pg.28]    [Pg.49]    [Pg.127]    [Pg.196]    [Pg.211]    [Pg.413]    [Pg.414]    [Pg.417]    [Pg.255]    [Pg.997]    [Pg.38]    [Pg.770]    [Pg.229]    [Pg.321]    [Pg.207]    [Pg.13]    [Pg.13]    [Pg.27]    [Pg.338]    [Pg.64]    [Pg.331]    [Pg.437]    [Pg.285]    [Pg.104]    [Pg.294]    [Pg.878]    [Pg.223]   