Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

High microscopic methods

There are no known examples of supported clusters dispersed in crystallo-graphically equivalent positions on a crystalline support. Thus, no structures have been determined by X-ray diffraction crystallography, and the best available methods for structure determination are various spectroscopies (with interpretations based on comparisons with spectra of known compoimds) and microscopy. The more nearly uniform the clusters and their bonding to a support, the more nearly definitive are the spectroscopic methods however, the uniformities of these samples are not easy to assess, and the best microscopic methods are limited by the smallness of the clusters and their tendency to be affected by the electron beam in a transmission electron microscope furthermore, most supported metal clusters are highly reactive and... [Pg.217]

The above-mentioned method is effective in identifying the molecules of detected ions. However, because PVDF film is not permeable to light, it is difficult to observe tissue sections. To resolve this problem, we developed a method to fix tissue sections on transparent film, and then performed MS on those sections.6 We used a conductive film because we expected the ionization efficiency would increase when the electric charge accumulation on the sample was reduced. The film used for this purpose was a polyethylene terephthalate (PET) film with a thickness of 75-125 pm, having a 5 15-nm-thick layer of evaporated oxidation indium tin (ITO) upon it (ITO film). This film is used in touch-panel displays because of its high transparency and superior conductivity. We used it to perform MS/MS for tissue sections and succeeded in identifying multiple proteins from mass spectra.6 Therefore, the further development of this method will enable the application of the mass-microscopic method to observe tissue by optical microscope and to perform tandem mass spectrometry (MSn) at the observation part, simultaneously, enabling the identification of molecules included the part. [Pg.371]

Therefore, no detailed discussion on the interaction of any liposomes with any particular cell type should be stated here. We refer to several recent publications for a study of interaction of DOPE CHEMS liposomes and COS-7 and HUVEC (109) and for a study on size-dependent uptake of particles into B16-F10 (72). The combination of flow cytometry and a microscopic method (e.g., spectral bio-imaging) turned out to be highly useful both to study the initial mode of internalization and to follow the intracellular fate of liposomes and other particulate carrier systems. [Pg.372]

We presented fully self-consistent separable random-phase-approximation (SRPA) method for description of linear dynamics of different finite Fermi-systems. The method is very general, physically transparent, convenient for the analysis and treatment of the results. SRPA drastically simplifies the calculations. It allows to get a high numerical accuracy with a minimal computational effort. The method is especially effective for systems with a number of particles 10 — 10, where quantum-shell effects in the spectra and responses are significant. In such systems, the familiar macroscopic methods are too rough while the full-scale microscopic methods are too expensive. SRPA seems to be here the best compromise between quality of the results and the computational effort. As the most involved methods, SRPA describes the Landau damping, one of the most important characteristics of the collective motion. SRPA results can be obtained in terms of both separate RPA states and the strength function (linear response to external fields). [Pg.147]

Another problem encountered in hardness measurement of microcrystalline materials by a microscopic method is the very high scatter of results (measurements made on grains and on intergrain bonds), with a common low evaluation of the hardness of a material as a whole. A. Szy-... [Pg.253]

The pulsed field gradient NMR technique can be readily used for the determination of the water droplet size distribution in W/O emulsions or the oil droplet size distributions in O/W emulsions. Important advantages are the non-invasive nature, the ease of sample preparation, and the feet that pulsed field gradient NMR measures the droplet size distribution of the bulk in contrast with microscopic methods which estimate the size distribution of the surface. Both the proposed matrix method and the iterative curve fitting procedure can be successfully applied in a factory environment. The method can be implemented on a high as well as on a low resolution NMR spectrometer. [Pg.162]

There are three basic preparation techniques in light microscopical methods. Which is used depends on such factors as the necessity to retain structural relationships for high resolution work, the nature of the issue (basic chemico-structural information, resolution of organoleptic issues), etc. The preparative methods used are smears (or comminution) handsections or cryosections and sections of fixed, embedded product. [Pg.234]

In the recent literature the terms nanoparticles and nanosystems are used, in analogy to colloid and colloidal systems. The prefix nano indicates dimensions in the 1 to 100 nm range. This is above the atomic scale and, unless highly refined methods are used, below the resolution of a light microscope and thus also below the accuracy of optical microstructuring techniques. [Pg.2]

Although membrane proteins are more difficult to purify and crystallize than are water-soluble proteins, researchers using x-ray crystallographic or electron microscopic methods have determined the three-dimensional structures of more than 20 such proteins at sufficiently high resolution to discern the molecular details. As noted in Chapter 3. the structures of membrane proteins differ from those of soluble proteins with regard to the distribution of hydrophobic and hydrophilic groups. We will consider the structures of three membrane proteins in some detail. [Pg.502]

Table 8.3 High-magnification microscopic methods for textiles types of contrast and illumination ... Table 8.3 High-magnification microscopic methods for textiles types of contrast and illumination ...

See other pages where High microscopic methods is mentioned: [Pg.1673]    [Pg.2906]    [Pg.512]    [Pg.363]    [Pg.110]    [Pg.52]    [Pg.40]    [Pg.304]    [Pg.3]    [Pg.121]    [Pg.313]    [Pg.203]    [Pg.76]    [Pg.512]    [Pg.153]    [Pg.343]    [Pg.106]    [Pg.357]    [Pg.368]    [Pg.46]    [Pg.43]    [Pg.374]    [Pg.128]    [Pg.89]    [Pg.244]    [Pg.212]    [Pg.169]    [Pg.16]    [Pg.2709]    [Pg.586]    [Pg.329]    [Pg.3]    [Pg.294]    [Pg.273]    [Pg.657]    [Pg.509]    [Pg.586]    [Pg.174]    [Pg.92]   
See also in sourсe #XX -- [ Pg.392 ]




SEARCH



High methods

Microscopic method