Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fluorescence fluorescent probes

Grazing incidence excitation of a fluorescent probe in a phospholipid monolayer can also be used to indicate order. The collective tilt of the molecules in a domain inferred from such measurements is indicative of long-range orientational order [222]. [Pg.136]

Hasegawa M, Sugimura T, Shindo Y and Kitahara A 1996 Structure and properties of AOT reversed micelles as studied by the fluorescence probe technique Colloids Surf. A 109 305-18... [Pg.2605]

The sample cells for molecular fluorescence are similar to those for optical molecular absorption. Remote sensing with fiber-optic probes (see Figure 10.30) also can be adapted for use with either a fluorometer or spectrofluorometer. An analyte that is fluorescent can be monitored directly. For analytes that are not fluorescent, a suitable fluorescent probe molecule can be incorporated into the tip of the fiber-optic probe. The analyte s reaction with the probe molecule leads to an increase or decrease in fluorescence. [Pg.428]

Approximately a minimum of 1 to 5,000 is required before complexation is no longer dependent on molecular weight for small anions such as KI and l-ariiLinonaphthaLine-8-sulfonate (ANS) (86,87). The latter anion is a fluorescent probe that, when bound in hydrophobic environments, will display increased fluorescence and, as expected, shows this effect in the presence of aqueous PVP. PVP, when complexed with Hl, shrinks in si2e as it loses hydrodynamic volume, possibly because of interchain complexation. ANS, on the other hand, causes the polymer to swell by charge repulsion because it behaves like a typical polyelectrolyte (88). [Pg.531]

D Shalon, SJ Smith, PO Brown. A DNA microairay system for analyzing complex DNA samples using two-color fluorescent probe hybridization. Genome Res 6 639-645, 1996. MB Eisen, PT Spellman, PO Brown, D Botstem. Cluster analysis and display of genomewide expression patterns. Proc Natl Acad Sci USA 95 14863-14868, 1998. [Pg.348]

Zn-complexes with heterocyclic ligands as fluorescent probes for biological investigations 98CSR179. [Pg.218]

Group II assays consist of those monitoring cellular second messengers. Thus, activation of receptors to cause Gs-protein activation of adenylate cyclase will lead to elevation of cytosolic or extracellularly secreted cyclic AMP. This second messenger phosphorylates numerous cyclic AMP-dependent protein kinases, which go on to phosphorylate metabolic enzymes and transport and regulatory proteins (see Chapter 2). Cyclic AMP can be detected either radiometrically or with fluorescent probe technology. [Pg.83]

Experiments on transport, injection, electroluminescence, and fluorescence probe the spatial correlation within the film, therefore we expect that their response will be sensitive to the self-affinity of the film. This approach, which we proved useful in the analysis of AFM data of conjugated molecular thin films grown in high vacuum, has never been applied to optical and electrical techniques on these systems and might be an interesting route to explore. We have started to assess the influence of different spatial correlations in thin films on the optical and the electro-optical properties, as it will be described in the next section. [Pg.100]

The formation of a microphase structure can be sensitively detected by using hydrophobic fluorescent probes. Hydrophobic microdomains tend to solubilize hydrophobic small molecules present together in aqueous solution. For example, diphenylhexatriene (DHT) is hydrophobically bound to the St aggregates in ASt-x in aqueous solution and, as a result, the fluorescence intensity is greatly enhanced. Figure 9 shows the fluorescence intensity of DHT in the presence of ASt-x relative to the intensity in its absence (I/I0) as a function of the ASt-x concentration [29],... [Pg.67]

Van Paassen [57] describes the CMC of some polyether carboxylates with different fatty chains and EO degrees (Fig. 2). In an extensive study, Binana-Limbele et al. [59] investigated the micellar properties of the alkylpolyether carboxylates of the general formula CnH + OCF CH OCI COONa with n = 8, x = 5, and n = 12 and x = 5,1, and 9, by means of electrical conductivity (CMC, apparent micellar ionization degree) and time-resolved fluorescence probing (micelle aggregation number A7) as a function of temperature and surfactant concentration (Table 1). [Pg.324]

In an effort to understand how actin-actin interactions might be affected by the binding of the myosin head, and in order to gain more insight into the nature of the actin-myosin interface, we have investigated the nature of the kinetic actin-myosin intermediates involved in the process of S)-induced polymerization of G-actin. For this purpose, a variety of fluorescent probes (e.g., pyrene, NBD, AEDANS) have been covalently attached to the C-terminus of G-actin to probe the G-actin-S] interaction under conditions of tightest binding, i.e., in the absence of ATP. [Pg.54]

Okada et al. examined the effects of TBT on cellular content of glutathione (GSH) in rat thymocites using a flow cytometer and 5-chloromethylfluorescein diacetate, a fluorescent probe for monitoring the change in the cellular content of GSH. TBT at nanomolar concentrations reduced the cellular content of GSH. There is an important implication on the TBT-induced depletion of cellular GSH since GSH has an important role in protecting the cells against oxidative stress and chemical and metal intoxications. TBT-induced decrease in cellular content of GSH in thymocytes may increase the vulnerability of the immune system. ° ... [Pg.420]

Haugland, RP (1992), Handbook of Fluorescent Probes and Research Chemicals, Molecular Probs, p... [Pg.208]

Dendritic hosts can be used in aqueous solution to encapsulate water-soluble fluorescent probes. Changes in the photophysical properties of these encapsulated probes are useful to understand the properties of the microenvironment created by the dendritic interior. For example, adamantyl-terminated poly(pro-pylene amine) dendrimers from the first to the fifth generation (36 represents the third generation) can be dissolved in water at pH<7 in the presence of -cyclodextrin because of encapsulation of the hydrophobic adamantyl residue inside the /1-cyclodextrin cavity and the presence of protonated tertiary amine units inside the dendrimer [72]. Under these experimental conditions, 8-anifi-... [Pg.184]

Dendrimers containing a polar surface and an apolar interior can work as hosts of hydrophobic fluorescent probes in aqueous environment. In particular. [Pg.185]

Conformational changes within or near the ATP-binding site of H,K-ATPase have also been demonstrated with the reversible fluorescent probes TNP-ATP [97,98] and... [Pg.35]

Shaw, C.F. Ill, Schaeffer, N.A., Elder, R.C., Eidsness, M.K., Trooster, J.M. and Calls, G.H.M. (1984) Bovine serum albumin-gold thiomalate complex gold-197 Moessbauer, EXAFS and XANES, electrophoresis, sulfur-35 radiotracer, and fluorescent probe competition studies. Journal of the American Chemical Society, 106, 3511-3521. [Pg.311]

Three- and four-photon absorption of a multiphoton absorbing fluorescent probe. Appl. Opt., 43. 5394-5398. [Pg.152]

Baumgard, T, Hunt, G., Farkas, E. R., Webb, W. W. and Feigenson, G. W. (2007) Fluorescence probe partitioning between Lo/Ld phases in lipid membranes. Biochim. Biophys. Acta,... [Pg.238]

Figure 4.7 Changes in intraceiiuiar calcium in cultured rat ventricular myocytes exposed to oxidant stress. Calcium was measured using the fluorescent probe Fura>2. The ratio of the Fura-2 fluorescence measured at 340 and 380 nm excitation is shown and this is proportional to the intracellular calcium concentration. The fast-speed traces shown (note the 3.5 s time-scale) were recorded after various durations of oxidant stress. Myocytes under control conditions (before t = 0) show spontaneous calcium transients. These transients decreased in frequency with oxidant stress until cells failed to show spontaneous activity but continued to maintain a low intracellular calcium. Figure 4.7 Changes in intraceiiuiar calcium in cultured rat ventricular myocytes exposed to oxidant stress. Calcium was measured using the fluorescent probe Fura>2. The ratio of the Fura-2 fluorescence measured at 340 and 380 nm excitation is shown and this is proportional to the intracellular calcium concentration. The fast-speed traces shown (note the 3.5 s time-scale) were recorded after various durations of oxidant stress. Myocytes under control conditions (before t = 0) show spontaneous calcium transients. These transients decreased in frequency with oxidant stress until cells failed to show spontaneous activity but continued to maintain a low intracellular calcium.
P. J. Robinson, J. T. Walker, C. W. Keevil, and J. Cole, Reporter genes and fluorescent-probes for studying the colonisation of biofilms in a drinking-water supply line by enteric bacteria. FEMS Microbiol. 729 183 (1995). [Pg.409]

Fluorescent probes are divided in two categories, i.e., intrinsic and extrinsic probes. Tryptophan is the most widely used intrinsic probe. The absorption spectrum, centered at 280 nm, displays two overlapping absorbance transitions. In contrast, the fluorescence emission spectrum is broad and is characterized by a large Stokes shift, which varies with the polarity of the environment. The fluorescence emission peak is at about 350 nm in water but the peak shifts to about 315 nm in nonpolar media, such as within the hydrophobic core of folded proteins. Vitamin A, located in milk fat globules, may be used as an intrinsic probe to follow, for example, the changes of triglyceride physical state as a function of temperature [20]. Extrinsic probes are used to characterize molecular events when intrinsic fluorophores are absent or are so numerous that the interpretation of the data becomes ambiguous. Extrinsic probes may also be used to obtain additional or complementary information from a specific macromolecular domain or from an oil water interface. [Pg.267]


See other pages where Fluorescence fluorescent probes is mentioned: [Pg.821]    [Pg.266]    [Pg.102]    [Pg.220]    [Pg.99]    [Pg.71]    [Pg.134]    [Pg.71]    [Pg.260]    [Pg.199]    [Pg.204]    [Pg.276]    [Pg.66]    [Pg.341]    [Pg.121]    [Pg.127]    [Pg.186]    [Pg.372]    [Pg.89]    [Pg.129]    [Pg.179]    [Pg.667]    [Pg.271]    [Pg.272]    [Pg.282]    [Pg.282]    [Pg.284]   
See also in sourсe #XX -- [ Pg.122 ]

See also in sourсe #XX -- [ Pg.194 ]




SEARCH



Fluorescence probing

Fluorescent probes

© 2024 chempedia.info