Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Fluid delivery systems

Gas pressurized Monitor tank level and provide interlock for feed feed shut-off overpressurizes, alternate fluid delivery system (e.g., pump) centrifuge system when feed vessel delivery gas pressure to maximum safe empties working pressure of downstream system (e.g., pressure regulation) Restrict feed flow rate to be consistent with vent capacity Ensure adequate vent capacity for maximum possible gas flow ... [Pg.64]

A schematic diagram of a chromatograph for SFC is shown in Figure 6.10. In general, the instrument components are a hybrid of components developed for gas and liquid chromatography that have been subsequently modified for use with supercritical fluids. Thus, the. fluid delivery system is a pump modified for pressure control and the injection system a rotary valve similar to components used in liquid chromatography. The column oven and... [Pg.832]

In 1996, workers at GlaxoWellcome disclosed the solution-phase preparation of 2-aminothiazole combinatorial libraries [99], Utilizing 20 glass vials and a DPC liquid dispensing robot, they prepared a library of 2500 compounds by this procedure. Also in 1996, Argonaut reported the use of their computer-controlled fluid delivery system for biaryl synthesis via a Suzuki coupling reaction [61],... [Pg.73]

The Nautilus 2400 Synthesizer [16, 17] (Figure 13.6) is engineered as a closed-to-the-outside-atmosphere fluid delivery system. It is the first commercially available synthesizer of organic compounds that is not based on a robotic system. [Pg.326]

On the other hand, in the development of a complete biosensor instrument it is necessary to develop associated technologies, as the whole system usually consists of four integrated parts (i) a sensitive transducer for detection of the interaction, (ii) a fluid delivery system for sample handling, (iii) surface immobilization chemistries for receptor attachment and for regeneration, and (iv) control electronics, acquisition software and data evaluation. [Pg.420]

For many methods, including the electrochemical method currently under consideration, the only required sample preparation is to dissolve the salts in an accurately known volume. One approach builds the sensor(s) into the filter chamber. Computer-controlled, fluid-delivery systems can be used to add the required amount of water to the cell. An in situ stirring device might be required, and certainly some provision for flushing the chamber must be made. Such a system is conceptually relatively simple but does have a number of disadvantages. [Pg.66]

A typical SFE system comprises three integrated parts (Fig. 2) fluid delivery system, extraction cell of the analytes from the sample matrix, and subsequent collection (trapping) of the analytes. [Pg.996]

More recently, the use of other plasticizers in blood and intravenous fluid delivery systems has obviated concerns associated with DEHP. [Pg.734]

The SFC systems are grouped into two categories analytical SFC for chemical analysis and preparative SFC for scale-up chemical synthesis and purification. On a fundamental level, the instrumentation for SFC consists of the following (1) a fluid delivery system with high-pressure pumps to transport the sample in a mobile phase and to control the pressure (2) the column in a thermostat-controlled oven where the separation process occurs (3) a restrictor to maintain the high pressure in the column (4) a detection system and (5) a computer to control the system as well as to record the results (see Figure 9.5 as an example). In SFC the mobile phase... [Pg.280]

Fig. 4. The Gesim nanoplotter, a robotic fluid delivery system that facilitates the production of chemotropic gradients. Fig. 4. The Gesim nanoplotter, a robotic fluid delivery system that facilitates the production of chemotropic gradients.
The above-mentioned properties are required at the orifice, if the fluid is heated or cooled. Higher viscosities are tolerated in fluid delivery system if this does not create a pressure drop that limits the desired maximum frequency. For high density fluids such as molten metals, the fluid properties should be converted to kinematic values to determine if The fluid properties are acceptable for dispensing. [Pg.211]

The advantages of ESI are that liquid samples may be introduced directly into the IMS, molecular information is retained due to the soft ionization processes, and in several cases multiply charged ions may be formed. The main limitation with ESI for practical analytical IMS is that relatively long rinsing times are needed between samples because memory effects in the fluid delivery system can be quite significant. [Pg.77]

In wet processing, silicon wafers are cleaned and etched, and then cleaned of photoresist and residuals from the etching process. Components made from PFA are used in tools and fluid delivery systems to help prevent contamination. System components which are commonly made from PFA or lined with PFA include piping, valves. [Pg.607]


See other pages where Fluid delivery systems is mentioned: [Pg.321]    [Pg.350]    [Pg.569]    [Pg.596]    [Pg.596]    [Pg.93]    [Pg.1831]    [Pg.1443]    [Pg.467]    [Pg.1101]    [Pg.259]   
See also in sourсe #XX -- [ Pg.596 ]




SEARCH



Fluid delivery

Fluid delivery systems syringe pumps

Fluid systems

© 2024 chempedia.info