Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Factors resulting

Health and Safety Factors. Results of acute oral toxicity studies of 2-pyrrohdinone on white rats and guinea pigs show the LD q to be 6.5 ml,/kg. Skin patch tests on 200 human subjects indicate that 2-pyrrohdinone is a skin kritant, but there is no indication of sensitising action. It is a mild eye irritant (79). [Pg.361]

Particulate Emissions To meet environmental regulations, AFBC boilers, and some PFBC boilers, use a back-end particulate collector, such as a baghouse or an electrostatic precipitator (ESP). Compared to PC units, the ash from FBCs has higher resistivity and is finer Decause the flue-gas path contains cyclones. Both factors result in reduced ESP collection efficiency with AFBC units, but good performance has been achieved with PFBC units, where the SO3 present in the flue gas lowers the ash resistivity. In general, however, bag-houses are the preferred collection devices for both AFBC and PFBC apphcations. [Pg.2387]

In designing the push-pull hood, one always applies a safety factor, , resulting in the exhaust flow rate for design, which is expressed as the following ... [Pg.972]

One of the oldest, simplest, and most efficient methods for removing solid particulate contaminants from gas streams is by filtration through fabric media. The fabric filter is capable of providing high collection efficiencies for particles as small as 0.5 pm and will remove a substantial quantity of particles as small as 0.01 pm. In its simplest form, the industrial fabric filter consists of a woven or felted fabric through which dust-laden gases are forced. A combination of factors results in the collection of particles on the fabric filters. When woven fabrics arc used, a dust cake eventually forms. This, in turn, acts predominantly as a sieving mechanism. When felted fabrics are used, the dust cake is minimal or nonc.xistent. [Pg.150]

The sum over Cl coefficients is an interference factor resulting from the fact that the full Cl pair energies converge faster than the second-order pair energies. [Pg.280]

Most workers in exploratory experiments use high grade solvents for it helps avoid complicating factors. Results thus obtained cannot necessarily be extrapolated safely to technical, reused, or reclaimed solvents, and serious errors have been made by doing so. If, in commercial practice, a lower grade solvent is to be used, its effect on the catalyst should be ascertained beforehand. [Pg.8]

For the first six substituents in Table 5-1 K2 is 3 to 5 powers of 10 greater than Kx. At pH = pATm the maximum equilibrium concentration of the (Z)-diazohydroxide (last column) is very small. For the 2,6-dichloro-4-nitrobenzenediazonium ion, however, Kx is smaller than K2 by a factor of only 101 67 = 37. This factor results in a significantly higher maximum concentration of the (Z)-diazohydroxide. Finally, the benzene-l-diazonium-4-diazohydroxide cation reaches a maximum equilibrium concentration of approximatively 80% at pH = pKm because, as mentioned before, Ki is larger than K2 by a factor of ten. [Pg.95]

Vitamin B12 is essential to growth, cell reproduction, the manufacture of myelin (which surrounds some nerve fibers), and blood cell manufacture. The intrinsic factor, which is produced by cells in the stomach, is necessary for the absorption of vitamin B12 in the intestine A deficiency of the intrinsic factor results in abnormal formation of erythrocytes because of the body s failure to absorb vitamin B12, a necessary component for blood cell formation. The resulting anemia is a type of megaloblastic anemia called pernicious anemia. [Pg.437]

Insulin and other growth factors result in the phosphorylation of BP-1 at five unique sites. Phosphorylation of BP-1 results in its dissociation from 4E, and it cannot rebind until critical sites are dephosphorylated. The protein kinase responsible has not been identified, but it appears to be different from the one that phos-phorylates 4E. A kinase in the mammalian target of rapamycin (mTOR) pathway, perhaps mTOR itself, is involved. These effects on the activation of 4E explain in part how insuhn causes a marked posttranscriptional... [Pg.367]

The other factor deficiencies are rare genetic disorders. Mutations in the gene for the respective clotting factors results in impaired functionality or production of the factor (Table 64-7). [Pg.994]

Coordinates such as these, which have the symmetry properties of the point group are known as symmetry coordinates. As they transform in the same manner as the IRs when used as basis coordinates, they factor the secular determinant into block-diagonal form. Thus, while normal coordinates most be found to diagonalize the secular determinant, the factorization resulting horn the use of symmetry coordinates often provides considerable simplification of the vibrational problem. Furthermore, symmetry coordinates can be chosen a priori by a simple analysis of the molecular structure. [Pg.122]

The steric factor results from physical interactions between atoms. From this factor comes the basic chirality. For the cases of solid metal catalysts, chirality may come from the support, the arrangement of active sites on the metal surface (Ogston concept1), or from an adsorbed or attached chiral entity. [Pg.112]

The prerequisite for an experimental test of a molecular model by quasi-elastic neutron scattering is the calculation of the dynamic structure factors resulting from it. As outlined in Section 2 two different correlation functions may be determined by means of neutron scattering. In the case of coherent scattering, all partial waves emanating from different scattering centers are capable of interference the Fourier transform of the pair-correlation function is measured Eq. (4a). In contrast, incoherent scattering, where the interferences from partial waves of different scatterers are destructive, measures the self-correlation function [Eq. (4b)]. [Pg.14]

Some of the 220 detectors recently recovered have been analysed not only for radon exposure but also to determine the value of F (the equilibrium factor) in the houses. A preliminary set of such F factor results, obtained by analysing the inner and outer LR- 115 track densities of each detector, are presented in Table III for 12 houses with mean indoor radon concentrations greater than 200 Bq/nP. In Table III are also presented radon daughter doses estimated using the individually determined equilibrium factor values F together with the doses estimated on the basis of an assumed mean F factor value of 0.45. [Pg.125]

Master curves can often be made for crystalline as well as for amorphous polymers (33-38). The horizontal shift factor, however, will generally not correspond to a WLF shift factor. In addition, a vertical shift factor is generally required which, has a strong dependence on temperature (36-38). At least part of the vertical shift factor results from the change in... [Pg.80]


See other pages where Factors resulting is mentioned: [Pg.671]    [Pg.429]    [Pg.28]    [Pg.188]    [Pg.24]    [Pg.36]    [Pg.173]    [Pg.366]    [Pg.158]    [Pg.637]    [Pg.381]    [Pg.522]    [Pg.249]    [Pg.78]    [Pg.72]    [Pg.201]    [Pg.117]    [Pg.222]    [Pg.367]    [Pg.80]    [Pg.195]    [Pg.269]    [Pg.504]    [Pg.123]    [Pg.101]    [Pg.130]    [Pg.58]    [Pg.93]    [Pg.184]    [Pg.183]    [Pg.29]    [Pg.111]    [Pg.101]    [Pg.230]    [Pg.172]    [Pg.39]   
See also in sourсe #XX -- [ Pg.424 ]




SEARCH



Errors, Limitations, and Other Factors Affecting Results

Etching results, factors influencing

Factors affecting experimental results

Results Obtained in a Factor VIII Assay

Results on the influences of various factors

© 2024 chempedia.info