In addition to fulfilling the in-house requirements for quality control, state and local air monitoring networks which are collecting data for compliance purposes are required to have an external performance audit on an annual basis. Under this program, an independent organization supplies externally calibrated sources of air pollutant gases to be measured by the instrumentation undergoing audit. An audit report summarizes the performance of the instruments. If necessary, further action must be taken to eliminate any major discrepancies between the internal and external calibration results. [Pg.224]

Self-calibrating features should not be relied upon to the exclusion of any external performance check. The frequency of periodic checks on self-calibrating features will depend on how often the features are used, scale, criticality, and tolerance. Typically armual checks should be conducted on self-calibrating features. [Pg.261]

According to the proposed USP chapter, performance verification is performed with a single external performance verification standard, after operational qualification has shown that the equipment is acceptable for use. Such standards should match the format, size, and shape of actual samples as closely as possible. Frequent analysis of the standard allows reverification of the instrument performance on a continuing basis. Ideally, such performance verification is run before and after each series of analytical measurements to verify both wavelength accuracy and photometric accuracy. [Pg.118]

Finally, the scarce motivation of laboratories in the validation and external performance evaluation of SMETs also has to be mentioned. This may be due to the fact that these methods are not yet extensively applied in monitoring and that the Directives usually do not clearly suggest their application in monitoring. SMETs are applied in research laboratories, but not in routine laboratories. If the Directives included the possibility of the application of these methods in monitoring, it would certainly contribute to a rapid and diffuse spread of SMETs outside the academic world. [Pg.368]

More investigation conducted with a control group to measure external performance criteria such as reduction in near miss incidents and in reinforcement methods to ensure greater effectiveness and sustainability seems warranted for the process. [Pg.255]

Broaching tools can be single or combination types, internal or external, performing either roughing or finishing operations. [Pg.145]

Some of the approaches and techniques for measuring performance and managing the constraints of the subsurface and surface facilities, and the internal and external factors will be discussed in this section. [Pg.331]

The necessary material to perform annual verification of flaw detector is mainly composed of an electronic function generator, an external calibrated attenuator and an oscilloscope. [Pg.703]

ZIXDO/S is parameteri/ed to reproduce spectroscopic transitions, therefore we do not recommend using this method for geometry optim i/ation. You can obtain better results by performing a single-point calculation wuth ZIXDO/S on a geometry obtained from the Model Builder, an optim Ization iisln g one of IlyperChem s oth er methods, or an external source. [Pg.151]

Agency. A second example of an external method of quality assessment is the voluntary participation of the laboratory in a collaborative test (Chapter 14) sponsored by a professional organization such as the Association of Official Analytical Chemists. Finally, individuals contracting with a laboratory can perform their own external quality assessment by submitting blind duplicate samples and blind standard samples to the laboratory for analysis. If the results for the quality assessment samples are unacceptable, then there is good reason to consider the results suspect for other samples provided by the laboratory. [Pg.712]

After densiftcation, external electrode termination and leads are attached for MLC capacitor components, and pin module assembly and IC chip joining is carried out for MLC packages. The devices are then tested to ensure performance and overall reflabiUty. [Pg.313]

A viable electrocatalyst operating with minimal polarization for the direct electrochemical oxidation of methanol at low temperature would strongly enhance the competitive position of fuel ceU systems for transportation appHcations. Fuel ceUs that directiy oxidize CH OH would eliminate the need for an external reformer in fuel ceU systems resulting in a less complex, more lightweight system occupying less volume and having lower cost. Improvement in the performance of PFFCs for transportation appHcations, which operate close to ambient temperatures and utilize steam-reformed CH OH, would be a more CO-tolerant anode electrocatalyst. Such an electrocatalyst would reduce the need to pretreat the steam-reformed CH OH to lower the CO content in the anode fuel gas. Platinum—mthenium alloys show encouraging performance for the direct oxidation of methanol. [Pg.586]


See other pages where External performance is mentioned: [Pg.171]    [Pg.103]    [Pg.176]    [Pg.163]    [Pg.1709]    [Pg.92]    [Pg.232]    [Pg.666]    [Pg.23]    [Pg.92]    [Pg.350]    [Pg.101]    [Pg.21]    [Pg.10]    [Pg.211]    [Pg.171]    [Pg.103]    [Pg.176]    [Pg.163]    [Pg.1709]    [Pg.92]    [Pg.232]    [Pg.666]    [Pg.23]    [Pg.92]    [Pg.350]    [Pg.101]    [Pg.21]    [Pg.10]    [Pg.211]    [Pg.55]    [Pg.331]    [Pg.695]    [Pg.801]    [Pg.1011]    [Pg.39]    [Pg.45]    [Pg.49]    [Pg.53]    [Pg.134]    [Pg.370]    [Pg.246]    [Pg.314]    [Pg.642]    [Pg.76]    [Pg.246]    [Pg.199]    [Pg.288]    [Pg.417]    [Pg.73]    [Pg.583]    [Pg.414]   