Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Evaporators Accessories

Vent connections ara normally provided. In many cases they must be permanently installed. In other cases intermittent venting may be acceptable. See Chapter 13 on Evaporator Performance for a discussion of evaporator and evaporator accessory venting. [Pg.322]

Direct-expansions are more appropriate for smaller systems which should be compact, and where there are just one or few evaporators. Overfeed (recirculation) systems should be considered for aU applications where first cost for additional equipment (surge drums, low-pressure receivers, refrigerant pumps, and accessories) is lower than the savings for the evaporator surface. [Pg.1117]

In the early days of flame spectrometry, some very elaborate accessories were designed to give reproducible discrete sample nebulization.16,17 However, as the technique became more widely employed, the devices used became progressively simpler, often taking the form of small funnels with a capillary bore outlet connected directly to the nebulizer capillary.17 Even this is not really necessary, because all that is required is a small (1-2 ml capacity) beaker with a conical depression in the bottom. Conventional Auto Analyser sample cups work very well. The end of the flexible nebulizer aspiration tube is simply dipped into the droplet of solution in the cone. This is especially useful if, for example, such sample cups have been used for evaporative pre-concentration of water samples in a vacuum desiccator.19... [Pg.76]

Thin films of silicates have been produced by pressing powders in a diamond anvil cell (Hofmeister 1997), by cutting grain samples to submicron thick slices with an ultra-microtome (Bradley et al 1999), by electron-beam evaporation (Djouadi et al. 2005), and by laser deposition in a vacuum (Brucato et al. 2004). On one hand, powders produced in a laboratory are directly measured in transmittance when they are embedded in a matrix of transparent materials (e.g. KBr or polyethylene). On the other hand, reflectance measurements do not require the use of matrices powders of selected-size grains are directly measured with an appropriate optical accessory. Through measurements in both transmittance and reflectance, it is possible to evaluate the optical constants of a material. These are certainly the physical parameters... [Pg.136]

Dry eye results from an unstable tear film or tear evaporation, which results in damage to the ocular surface. The Unified Theory published in 1998 provided the basis for understanding dry eye as an inflammatory disease of the integrated lacrimal functional unit.The lacrimal functional unit consists of the ocular surface (cornea, meibomian glands, and conjunctiva), main and accessory lacrimal glands, and their interconnecting nerves. In the healthy state the lacrimal functional unit maintains a... [Pg.238]

The Karl Fischer test method (ASTM D-1364, ASTM D-6304) covers the direct determination of water in petroleum. In the test, the sample injection in the titration vessel can be performed on a volumetric or gravimetric basis. Viscous samples can be analyzed with a water vaporizer accessory that heats the sample in the evaporation chamber, and the vaporized water is carried into the Karl Fischer titration cell by a dry, inert carrier gas. [Pg.48]

The Karl Fischer method is applied in a multitude of substances from finished products (butter, cheese, dried milk sugar, etc.) to solvents and other industrial products (paper, gas, petroleum, plastic films, etc.). Solids and not soluble samples must, prior to the measurement, either be ground into powders, extracted with anhydrous solvents, eliminated as azeotropes or heated to evaporate the water in special accessories. The only difficult cases are encountered with strongly acidic or basic media since they denature reactants as well as ketones and aldehydes which perturb the titration through formation of acetals (special reagents must be used for these instances). [Pg.481]


See other pages where Evaporators Accessories is mentioned: [Pg.1033]    [Pg.1146]    [Pg.2185]    [Pg.41]    [Pg.856]    [Pg.969]    [Pg.1941]    [Pg.1199]    [Pg.1315]    [Pg.2434]    [Pg.1200]    [Pg.1316]    [Pg.2415]    [Pg.1037]    [Pg.1150]    [Pg.2189]    [Pg.119]    [Pg.171]    [Pg.210]    [Pg.1033]    [Pg.1146]    [Pg.2185]    [Pg.41]    [Pg.856]    [Pg.969]    [Pg.1941]    [Pg.1199]    [Pg.1315]    [Pg.2434]    [Pg.1200]    [Pg.1316]    [Pg.2415]    [Pg.1037]    [Pg.1150]    [Pg.2189]    [Pg.119]    [Pg.171]    [Pg.210]    [Pg.167]    [Pg.364]    [Pg.314]    [Pg.491]    [Pg.535]    [Pg.73]    [Pg.318]    [Pg.782]    [Pg.445]    [Pg.63]    [Pg.1145]    [Pg.64]    [Pg.479]    [Pg.731]    [Pg.115]    [Pg.389]    [Pg.76]    [Pg.430]   
See also in sourсe #XX -- [ Pg.210 ]




SEARCH



Accessories

Evaporator Accessories

Evaporator Accessories

© 2024 chempedia.info