Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Size-selectivity

The relation between the inner diameter d and the conductance g of synthetic ion channels and pores is described in the Hill equation [5]. [Pg.402]

Supramolecular chemists without BLM-workstation can approximate the inner diameter of synthetic ion channels and pores by size exclusion experiments in LUVs. Differences in activity between the HPTS assay - compatible with all diameters - and the ANTS/DPX assay reserved for pores with diameter larger than 5 A and the CF assay for pores with larger than 10A can differentiate between ion channels and pores (Fig. 11.5). Larger fluorescent probes like CF-dextrans are available to identify giant pores or defects [26]. However, we caution [Pg.402]


The reactivity of size-selected transition-metal cluster ions has been studied witli various types of mass spectrometric teclmiques [1 ]. Fourier-transfonn ion cyclotron resonance (FT-ICR) is a particularly powerful teclmique in which a cluster ion can be stored and cooled before experimentation. Thus, multiple reaction steps can be followed in FT-ICR, in addition to its high sensitivity and mass resolution. Many chemical reaction studies of transition-metal clusters witli simple reactants and hydrocarbons have been carried out using FT-ICR [49, 58]. [Pg.2394]

Buck U, Gu X, Lauenstein C and Rudolph A 1988 Infrared photodissociation spectra of size-selected (CHjGH) clusters from / = 2 to 8 J. Phys. Chem. 92 5561... [Pg.2401]

Wang L S, Cheng H S and Fan J 1995 Photoeieotron spectroscopy of size-selected transition metal clusters Kc , n = 3-24 J. Chem. Phys. 102 9480... [Pg.2404]

The size selectivity of a particular packing is not infinite, but is limited to a moderate range. All solutes significantly smaller than the pores move through the column s entire volume and elute simultaneously, with a retention volume, Vj, of... [Pg.593]

Examples of the application of size-exclusion chromatography to the analysis of proteins. The separation in (a) uses a single column that in (b) uses three columns, providing a wider range of size selectivity. (Chromatograms courtesy of Alltech Associates, Inc. Deerfield, IL). [Pg.595]

Smaller pore size microfilters in single-pass systems which have pore sizes small enough to remove some vimses by size exclusion have been examined (26,37,38). Minimum levels of vims removal can be estabhshed for these systems if fluid and process conditions are employed which minimize removal of viral particles by mechanisms other than size selection. [Pg.144]

Zeohte 5A is used because its pores can size-selectively adsorb straight-chain molecules while excluding branched and cycHc species. The normal hydrocarbon fraction has better than 95% purity, and the higher octane isomer fraction contains less than 2% normal hydrocarbons (64). [Pg.283]

Results of test work with this filter, producing cakes of 1 mm thickness using a 3 mm clearance, have been pubUshed (33,34). The cake formed on the medium was generally stable, giving high filtration rates over long periods of time, and the precoat type cake did not blind with time. There was no evidence of any size selectivity of the process the only exception was conventional filter aids which were preferentially picked up by the rotating fluid. This... [Pg.411]

Molecular sieves have had increasing use in the dehydration of cracked gases in ethylene plants before low temperature fractionation for olefin production. The Type 3A molecular sieve is size-selective for water molecules and does not co-adsorb the olefin molecules. [Pg.456]

Pipe-Wall Thickness. Once the design pressure and temperature have been established and the pipe material and size selected, the wall thickness is calculated using the appropriate section of the code. In rare cases, a thin pipe must be made thicker to withstand handling. Occasionally the thickness is affected by external loads or vibrations. All codes prescribe essentially the same design formula for metallic hoUow circular cylinders under internal pressure ... [Pg.58]

Size selectivity is the most thorough method of expressing classifier performance under a given set of operating conditions. Cut size and sharpness can be calcinated from size-selectivity data. Size selectivity is defined by... [Pg.1835]

For pumoses of calculating size selectivity from cumulative particle size distribution data, Eq. (20-16) can be expressed in incremental form as follows ... [Pg.1835]

API RP 520. Sizing, Selection, and Installation of Pressure-Relieving Devices in Refineries. Part I, Sizing and Selection, 5th ed., July 1990, and Part II, InstaUation, 3d ed., November 1988. American Petroleum Institute, Washington, D.C. [Pg.2288]

Because a filter sample includes particles both larger and smaller than those retained in the human respiratory system (see Chapter 7, Section III), other types of samplers are used which allow measurement of the size ranges of particles retained in the respiratory system. Some of these are called dichotomous samplers because they allow separate measurement of the respirable and nonrespirable fractions of the total. Size-selective samplers rely on impactors, miniature cyclones, and other means. The United States has selected the size fraction below an aerodynamic diameter of 10 /xm (PMiq) for compliance with the air quality standard for airborne particulate matter. [Pg.47]

API Recommended Practice 520 , Sizing, Selection, and Installation of Pressure Relieving Devices in Refineries, 1993. [Pg.284]

The particles most likely to cause adverse health effects are the fine particulates, in particular, particles smaller than 10 p and 2.5 mm in aerodynamic diameter, respectively. They are sampled using (a) a high-volume sampler with a size-selective inlet using a quartz filter or (b) a dichotomous sampler that operates at a slower flow rate, separating on a Teflon filter particles smaller than 2.5 mm and sizes between 2.5 mm and 10 mm. No generally accepted conversion method exists between TSP and PM,o, which may constitute between 40% and 70% of TSP. In 1987, the USEPA switched its air quality standards from TSP to PMk,. PM,q standards have also been adopted in, for example, Brazil, Japan, and the Philippines. In light of the emerging evidence on the health impacts of fine particulates, the USEPA has proposed that U.S. ambient standards for airborne particulates be defined in terms of fine particulate matter. [Pg.16]

The aerodynamic particle diameter determines the fate of particles in the respiratory system. Coarse particles are deposited in the nose and nasopharynx. Smaller particles that pass the upper airway can be deposited in the bronchial region and lower airway. A size-selective deposition model and sampling of particles has been standardized both in Europe and internationally. The... [Pg.264]

Size-selective sampling Industtial hygiene sampling methods that collect particles with a specific range of aerodynamic diameters. [Pg.1476]

As piping drawings are developed, re-evaluate those lines where estimated pressure drop was a criterion in size selection, taking into account the actual piping configuration and effects of control and piping components. [Pg.447]

Z. Tang, L. E. Scriven, H. T. Davis. Size selectivity in adsorptions of poly-disperse hard-rod fluids in micropores. J Chem Phys 97 5732-5737, 1992. [Pg.71]


See other pages where Size-selectivity is mentioned: [Pg.339]    [Pg.2390]    [Pg.2395]    [Pg.2397]    [Pg.2398]    [Pg.2901]    [Pg.185]    [Pg.280]    [Pg.284]    [Pg.284]    [Pg.499]    [Pg.107]    [Pg.449]    [Pg.42]    [Pg.265]    [Pg.196]    [Pg.1541]    [Pg.1543]    [Pg.1543]    [Pg.1544]    [Pg.1822]    [Pg.1836]    [Pg.2480]    [Pg.2524]    [Pg.372]    [Pg.43]    [Pg.30]   
See also in sourсe #XX -- [ Pg.399 ]

See also in sourсe #XX -- [ Pg.9 ]

See also in sourсe #XX -- [ Pg.131 ]

See also in sourсe #XX -- [ Pg.175 ]




SEARCH



© 2024 chempedia.info