Electrical installation power supplies

Standby supply systems within an electrical installation provide supplies to critical loads on loss of normal power supplies. In an installation one or more of the following types of standby supply systems are likely to be found ... [Pg.224]

Power Supplies and Controls. Induction heating furnace loads rarely can be connected directiy to the user s electric power distribution system. If the load is to operate at the supply frequency, a transformer is used to provide the proper load voltage as weU as isolation from the supply system. Adjustment of the load voltage can be achieved by means of a tapped transformer or by use of a solid-state switch. The low power factor of an induction load can be corrected by installing a capacitor bank in the primary or secondary circuit. [Pg.127]

Economics Power-recoveiy units have no operating costs in essence, the energy is available free. Furthermore, there is no incremental capital cost for energy supply. Incremental installed energy-system costs for a steam-turbine driver and supply system amount to about 800 per kilowatt, and the incremental cost of an electric-motor driver plus supply system is about 80 per kilowatt. By contrast, even the highest-inlet-pressure, largest-flow power-recoveiy machines will seldom have an equipment cost of more than 140 per kilowatt, and costs frequently are as low as 64 per kilowatt. However, at bare driver costs (not including power supply) of 64 to 140 per kilowatt for the power-recovery driver versus about 30 to 80 per Idlowatt for... [Pg.2524]

The object of any electrical power distribution scheme is to provide a power supply system that will convey power economically and reliably from the supply point to the many loads throughout the installation. The standard method of supplying reliable electrical supplies to a load center is to provide duplicated 100 per cent rated supplies. However, there are a number of ways in which these supplies can be provided. [Pg.211]

If an auxiliary power supply is to be installed, its size must be determined. It should be large enough either to shut down all processes safely or to maintain them at a minimal operating level, assuming there is a complete failure of the incoming electrical supply. [Pg.209]

The electrical power of both plants (XX kW) is supplied by the main power supply of building (F). An emergency diesel power supply ofYY kW is installed, which switches on 1 min after a power break. (If YY is not equal to XX The sequence of components to be connected to the emergency set is listed in directive (q), deposited at the control center). The control- and calculating system of both plants is connected by shielded cables to an independent power supply system, called computer power, that excludes influences of power variation or breakdown. [Pg.261]

To the Foundation for Science and Technology and the Azores Regional Government for the financial support to the project, to the Azores Electricity company for the installation of the power supply, and to Mister Francisco Carrondo for allowing the installation of the sampling instrument in his lands. [Pg.142]

An improved electrochemical cell for in situ studies is presented in Figure 14.2. In this method a platinized Pt electrode located in the anode compartment serves as the reference electrode. This cell can be installed in a test station. Such a station can have facilities for temperature and pressure control, humidification of reactant gases (e.g., hydrogen and oxygen), gas flow rate measurement, and measurement of half-and single-cell potentials as a function of current density. Finally, electrical leads from this test station could be connected to, say, power supplies. [Pg.222]

Figure 6.10 shows a typical example for a q-apparatus. It is a power supply for intrinsically safe electric circuits to be installed in zone 1 (and zone 2). The power input (at 24 V AC/DC level) is fed via flameproof plug-and-socket connectors to the apparatus. So, the power supply can be replaced under load without conflicting with the requirements of explosion protection. [Pg.134]

Network conflicts Electrical installation Cable connections Electrical testing Uninterrupted power supplies Input/output... [Pg.723]

The electric field runs were conducted in a companion shock tube with ports for inserting a large cylindrical electrode see Figure 1). The electrode was a 5.4-cm diameter copper electrode mounted in a Plexiglas insulator. The assembly was installed fiush with the bottom wall. The electrode/tube apparatus operated much like an ionization chamber. A D.C. power supply provided continuous output from 100 to 4000 V, giving a field strength of up to 500 V/cm. [Pg.169]

Composite materials are extensively used in modem wind turbine rotor blades. These blades have exhibited a significant increase in length over the past few years (blade lengths exceed 30 m). In addition, wind turbines are increasingly being installed collectively in wind farms, to serve as large electricity plants rather than stand-alone power supply. The associated high investments call for accurate and reliable lifetime prediction methods for the whole turbine, but especially for the blades, which are difficult to repair and to reinstall. [Pg.563]

Secondary services are typically installed for small- to medium-size pharmaceutical plants. They are available at the utilization voltages of 277/480 or 120/208 V. Secondary services are less expensive to install and maintain than primary services. However, the kilowatt-hour cost for electrical power supplied by a secondary service is higher. [Pg.1483]

PAFC are mainly used in stationary power plants for distributed heat and power generation. Power plants, with outputs of single modules in the order of 200 kW, have been installed worldwide supplying, for example, shopping malls or hospitals with electricity, heat and hot water. [Pg.345]


See other pages where Electrical installation power supplies is mentioned: [Pg.347]    [Pg.169]    [Pg.311]    [Pg.254]    [Pg.62]    [Pg.36]    [Pg.45]    [Pg.352]    [Pg.478]    [Pg.162]    [Pg.338]    [Pg.15]    [Pg.477]    [Pg.95]    [Pg.14]    [Pg.299]    [Pg.190]    [Pg.352]    [Pg.478]    [Pg.563]    [Pg.845]    [Pg.117]    [Pg.37]    [Pg.137]    [Pg.273]    [Pg.284]    [Pg.99]    [Pg.467]    [Pg.509]    [Pg.226]    [Pg.137]   