Electric power system protection monitoring

ELECTRIC POWER, SYSTEM PROTECTION, CONTROL, AND MONITORING OF... [Pg.415]

See also-. Climatic Effects Consumption Domestic Energy Use Electric Motor Systems Electric Power, Generation of Electric Power, System Protection, Control, and Monitoring of Electric Power Substations Electric Power Transmission and Distribution Systems Government and the Energy Marketplace Regulation and Rates for Electricity. [Pg.427]

Electric Power, System Protection, Control, and Monitoring of... [Pg.1290]

An electric power substation is a facility that provides a junction between parts of the power grid. The substation s functions, critical for the proper operation of the power system, include the interconnection of power lines from different parts of the system the monitoring and control of system operating conditions and the protection of the power system equipment. [Pg.428]

E/E/PE It represents the control/protection/monitoring system and/or combination of them, based on one or more electrical/electronic/ programmable electronic (E/E/PE) devices including all elements of the system such as power supply, sensor, input/output (I/O), control system, final elements, etc. The terms encompasses hardware, software, and I/O. [Pg.928]

Because the engineered safety features are passive systems or are actuated by the protection and safety monitoring system (with diverse actuation system (DAS) backup), whereas the plant duty systems are electrically powered and actuated by the plant control system (PLS), there is significant diversity between the duty and protection systems. [Pg.119]

Use a break-detection system that is automatically tied into the laser-power interlock loop. Such a system continuously monitors the integrity of the laser fiber path and causes a laser shutdown in the event that fiber integrity is not confirmed. There are different methods of performing such a monitoring function. One simple method is to run an interlock wire loop in the same protective jacket as the fiber, on the theory that both the fiber and the wire would be broken simultaneously. One disadvantage of this method is that it does not directly monitor the laser fiber itself. Another is that it requires an electrical current to be broken, which raises the possibility of other safety hazards. [Pg.139]

The four divisions (guard lines) of the protection and safety monitoring system and its uninterruptible power supply, the electrical penetrations through the containment, portions of the plant control system, the main control room and the remote shutdown workstation are concentrated within the northern section of the Auxiliary Building. A large fire or explosion in this area could render these features imusable for a significant amount of time. Such an event would most likely result in an immediate reactor trip, due to the loss of power and control... [Pg.353]


See other pages where Electric power system protection monitoring is mentioned: [Pg.1005]    [Pg.1204]    [Pg.243]    [Pg.479]    [Pg.173]    [Pg.534]    [Pg.527]    [Pg.487]    [Pg.423]    [Pg.291]    [Pg.236]    [Pg.173]    [Pg.109]    [Pg.190]    [Pg.236]    [Pg.236]    [Pg.72]    [Pg.294]    [Pg.2487]    [Pg.155]    [Pg.182]    [Pg.122]    [Pg.74]    [Pg.428]    [Pg.20]    [Pg.357]   
See also in sourсe #XX -- [ Pg.421 , Pg.422 ]




SEARCH



Electric Power System

Electric power

Electric power system protection

Electric power system protection control and monitoring

Electrical power systems

Electrical protection

Electrical system

Monitor system

Monitoring system

Power electrical

Power system

Protection systems

Protection systems, electrical

Protective systems

© 2024 chempedia.info