Absorbance and concentration

It must be present in sufficient concentration and absorb more strongly than the other reactants under the conditions of the experiment so that it is the major light absorber. [Pg.746]

The release of dimethyl sulfoxide is accompanied by an increase in absorbance (D) at 325 nm. The absorbance D is defined as log(I(/I), where 1 and I are die intensities of die incident and transmitted light, respectively. Figure 3-15 illustrates die relationship between concentration and absorbance changes for die hydrolysis of die cobalt... [Pg.156]

Figure 3-15. Reiationship between concentration and absorbance changes for the hydroiysis of [Co(NH3)5L] ... Figure 3-15. Reiationship between concentration and absorbance changes for the hydroiysis of [Co(NH3)5L] ...
The accuracy and precision of carotenoid quantification by HPLC depend on the standard purity and measurement of the peak areas thus quantification of overlapping peaks can cause high variation of peak areas. In addition, preparation and dilution of standard and sample solutions are among the main causes of error in quantitative analysis. For example, the absorbance levels at of lutein in concentrations up to 10 mM have a linear relationship between concentration and absorbance in hexane and MeOH on the other hand, the absorbance of P-carotene in hexane increased linearly with increasing concentration, whereas in MeOH, its absorbance increased linearly up to 5 mM but non-linearly at increasingly higher concentrations. In other words, when a stock solution of carotenoids is prepared, care should be taken to ensure that the compounds are fuUy soluble at the desired concentrations in a particular solvent. [Pg.471]

There are several good reasons to focus on linear models. Theory may indicate that a linear relation is to be expected, e.g. Lambert-Beer s law of the linear relationship between concentration and absorbance. Even when a linear relation does not hold strictly it can be a sufficiently good local approximation. Finally, one may try and find a transformation of the individual variables (e.g. a logarithmic transformation), in order to obtain an acceptable linear model for the transformed variables. Thus, we simplify eq. (36.1) to... [Pg.351]

In some cases, curved lines may be used as standard curves if they give a suitable equation for the line and an acceptable r2 is obtained (see below). However, it is always preferable to have a straight-line relationship between concentration and absorbance. [Pg.313]

J. Phys. Chem., in press]. From continuous radiolysis experiments, we have determined the yields of hydrogen and rhodium(I) as functions of pH, initial substrate concentration, and absorbed dose. [Pg.393]

Chinery RL, Gleason AK. 1993. A compartmental model for the prediction of breath concentration and absorbed dose of chloroform after exposure while showering. Risk Anal 13(1) 51-62. [Pg.257]

A problem in the application of FTIR to ambient air is that water vapor, C02, and CH4 are all present in significant concentrations and absorb strongly in certain regions of the spectrum. As a result, the spectral regions that are useful for ambient air measurements are 760- to 1300-cm-1, 2000- to 2230-cm-1, and 2390-to 3000-cm l. [Pg.551]

In this case, a is the differential optical absorption cross section for the absorption band. In practice, of course, there are many different absorbers, t, present at different concentrations and absorbing at different wavelengths over the path length L. [Pg.556]

A number of B.P. tests require derivatization of the substance under investigation before the UV absorbance is recorded. In these cases, in order to take account of the possibility of the reaction not proceeding to completion, the comparative method is employed, which makes use of a reference (defined in the B.P.). The concentrations and absorbances of the reference and substance under investigation are related by equation (2.5) ... [Pg.20]

Figure 17.6—Relationship between concentration and absorbance for ELISA assays. The ratio of both types of molecules at the wall is the same as that in solution (3 in the example shown). Linearity, plotted on a semi-logarithmic scale, is only observed for a very narrow range of concentrations. Figure 17.6—Relationship between concentration and absorbance for ELISA assays. The ratio of both types of molecules at the wall is the same as that in solution (3 in the example shown). Linearity, plotted on a semi-logarithmic scale, is only observed for a very narrow range of concentrations.
Another method that can be used to quickly extract useful chemical information from an infrared image dataset is MCR 50-52,54,56-58 In some cases, this method can be used to obtain the concentration and absorbance spectra for each constituent in the original dataset. However, if the goal is not necessarily to resolve the constituents spectra, but rather to empirically classify them, a regression method may be more appropriate.53,59,60 The most prominent multivariate regression methods include PLS and ANNs. [Pg.271]

A popular use of a spectrophotometer is to measure concentration using the relationship between concentration and absorbance described by the Beer-Lambert law, which dictates that the absorbance of a light-absorbing substance is proportional to its concentration in solution ... [Pg.107]

Siddiqui et al. [28] developed and validated an analytical spectral calibration method to quantify buclizine hydrochloride, which is a piperazine derivative and used a single active principle in pharmaceutical forms were done. The quantification of buclizine hydrochloride was performed in the wavelength range of 218-226 nm at N = 6. The linear regression equation has been constructed using relationship between concentration and absorbance at 218, 220, 222, 224, and 226 nm. [Pg.30]

We can see fipom this equation that absorbance is therefore proportional to the concentration level of absorbing species for given instrumental conditions. When however, the concentration and absorbance levels increase, the imperfections of the absorption process causes a deviation IVom the straight calibration line towards lower values. In order to obtain a precise measure of the concentration for a specimen situated in the non-linear response region, it is necessary to dilute it until an absorbance measurement in the linear domain is recorded. With state-of-the-art instruments fitted with micro-computers, a precise calibration can easily be established in a range of slight curvature. [Pg.41]

Using the optimum concentration range for Cd (0.05-2 mgl-1) prepare a series of six concentrations to be used in constructing a calibration curve for Cd. Record your concentrations and absorbance readings in the table in the Results Summary section. Plot the calibration curve for cadmium (absorbance vs concentration). [Pg.190]

Table 12 Correlation matrix between tryptophan concentration and absorbance at seven wavelengths for the 14 standard solutions from Table 11... Table 12 Correlation matrix between tryptophan concentration and absorbance at seven wavelengths for the 14 standard solutions from Table 11...
This is a colorimetric method and colour development is virtually instantaneous and no waiting is required before measuring fluoride concentration. Colour determinations are made photometrically, using a spectrophotometer. A curve developed from standards can be used for determining the fluoride concentration of a sample or the concentration can be calculated on the basis of a pair of standards. The latter technique makes use of the fact that the relationship between fluoride concentration and absorbance (within the range of the method) is linear and thus that two points can define accurately the position of the line. [Pg.128]

Unfair, I hear you mutter under your breath, velocities have a lower limit of zero but lack an upper limit, so it is no wonder that they exhibit an asymmetrical distribution. True enough, but this also applies to many other quantities, such as absolute temperature, mass, concentration, and absorbance. The point here is not why a number of distributions are decidedly non-Gaussian, but that they are. [Pg.75]


See other pages where Absorbance and concentration is mentioned: [Pg.232]    [Pg.30]    [Pg.125]    [Pg.312]    [Pg.227]    [Pg.387]    [Pg.258]    [Pg.73]    [Pg.256]    [Pg.7]    [Pg.78]    [Pg.232]    [Pg.334]    [Pg.65]    [Pg.286]    [Pg.327]    [Pg.540]    [Pg.127]    [Pg.13]    [Pg.720]    [Pg.227]    [Pg.22]    [Pg.168]    [Pg.227]    [Pg.111]    [Pg.57]    [Pg.613]   
See also in sourсe #XX -- [ Pg.385 , Pg.385 ]

See also in sourсe #XX -- [ Pg.48 ]

See also in sourсe #XX -- [ Pg.720 ]




SEARCH



The relationship between absorbance and concentration