Early separations

Early separators used in NiCd cells for space applications consisted of materials as ordinary as Whatman filter paper and eventually nonwoven nylon felt (Pellon 2505). Pellon 2505 was more stable than cellulosic separators, but it too had stability limitations. In the late 1960s and early 1970s, nonwoven polypropylene saw limited use in NiCd cells. The PP separators were quite useful where sterilization (heating the cell to 135 °C) was required.The major difficulty with nonwoven polypropylene was that it was only marginally wet-table. and the amount of electrolyte that can be placed in the cell was limited. [Pg.211]

Unfortunately, in spite of the published literature on wine proteins, we do not know the actual protein levels at which table or dessert wines are stable. The changes in protein content during production and processing of wines are still not known with sufficient accuracy to predict their behavior. The winemaker has to depend on empirical tests if he is to produce protein stable wines. Early separation of new wines from their fermentation yeast greatly improves their chances for protein stability by decreasing the release of yeast autolysis products into the wine. [Pg.132]

The early separation of the lanthanides was beset by difficulties as a result of the similarity in size and charge of the lanthanide ions. The separations were generally based on slight differences in solubility, which were exploited through schemes of fractional crystallization. The differences in behavior resulting from a decrease in ion... [Pg.843]

Separation of the The early separation of the lanthanides was beset by difficulties as a result of the... [Pg.843]

Early separation methods, based on the selective partition of crude taxine between an organic solvent and water solutions of different pH values [31] have been abandoned, and column chromatography on silica gel using mixtures of CHClj-EtOH as eluant is today the method of choice. Further purification can be achieved on TLC or with HPLC. Unlike crude taxine, taxane alkaloids are often crystalline compounds, especially those of the taxine A-type. [Pg.243]

Sequencing of 28-S ribosomal DNA [86] did not find support for an independent two-way separation of Haplosclerida s.l., but supported the hypothesis of an early separation of this group from other morphologically related groups such as the Poecilosclerida. [Pg.344]

Remove Corrosive and Unstable Materials Early. The early separation of corrosive and unstable melerials is desirable. The early removal of corrosive materials probably will increase the lifetime of downstream processing units or allow fbara to be constructed of less expensive materials. Unstable species that ate sensitive to temperature, shear, and so on should be removed early, as should potentially toxic components. Components thet might undergo unfavorable side reactions also should be removed early. [Pg.209]

Xenon isotopes in oceanic basalts provide the most basic evidence on early differentiation of our planet and on formation of the atmosphere. Several Xe isotopes are produced by extinct radioactivity, providing a method to quantify events at the very start of Earth history near 4500 million years ago to a high precision, within several tens of millions of years. The difference between Xe/ °Xe of the mantle and atmosphere is fundamental evidence for their early separation (e.g., Thompson 1980 Staudacher and Allegre 1982). It is thought that formation of the atmosphere involved some early degassing of the mantle. Whether the Earth ever had a primary atmosphere is still an open question, and ultimately depends upon whether the inner planets formed in the presence of a solar nebula gas phase. The timing of these early events, the degree to which Xe isotope differences reflect variations in I/Xe and Pu/Xe of source reservoirs, and the... [Pg.289]

Horizontal drum Separates gas, oil and water as for example as an early separation of natural gas upstream of drying or to handle sour water. Typically a relatively small load of hydrocarbon. Often called a flash drum . [Pg.149]

Early separations were slow, with typical analysis times of 3 h for a four-column system. This disadvantage has been overcome by the use of microparticulate column packings which reduce the analysis time to 45 minutes with a four-column system, or, in extremely favourable cases, to 9 minutes with a single ultra-high resolution column. The technique is well suited to automatic sample injection, which allows 24 hour operation of equipment. [Pg.134]

The first approach to automatic liquid chromatography (LC) of amino acids (AAs) - known today as ion-exchange chromatography - was published by Spackman, Stein, and Moore in 1958, which led to the award of the Nobel Prize in 1972 to Stanford Moore and William H. Stein. Forty-five years later, it now takes less than 5 min (Figure 1) to separate and quantitate the essential protein AAs instead of 2 days. Early separations were carried out by postcolumn derivatizations. [Pg.2667]

Ion-exchange chromatography has been used in the separation of ionic species for more than half a century. Early separations were achieved with either sulfonated or quatemized polystyrenedivinylbenzene (PSDVB). Unfortunately, these materials are often unsuitable for protein separations because the strong nonspecific adsorption between the hydrophobic sorbents and proteins necessitates the use of organic solvent or extremes in pH to achieve elution. Such conditions are sufficiently harsh to denature protein three-dimensional structure and, consequently, alter biological activity. [Pg.81]

MN-300 is a 0.1 mm thick native fibrous cellulose layer (fiber length 2-20 microns) made by Machery-Nagel and served as an early separation system. [Pg.930]

Some of the first data on californium complexes involved materials such as the halides, citrate, lactate, a-hydroxyisobutyrate, etc., as these materials played a role in early separation/purification schemes [7,23] (also see Section 11.4). In general, it is expected that only small differences in stability would exist between Cf(iii) and its trivalent neighbors Bk(iii) and Es(iii), with larger differences being found between Cf(iii) and Am(in). A general discussion of actinide complexes (including californium) in aqueous solution is available [198]. [Pg.183]

The results show that the external-internal cooling reduces significantly the cycle times particularly for the moulding of thick plastic products. According to Chen s off-line experimental results (13), the part warpage starts from the crystalline melting temperature,. An early separation... [Pg.143]


See other pages where Early separations is mentioned: [Pg.27]    [Pg.549]    [Pg.29]    [Pg.888]    [Pg.117]    [Pg.423]    [Pg.159]    [Pg.426]    [Pg.122]    [Pg.224]    [Pg.199]    [Pg.126]    [Pg.106]    [Pg.238]    [Pg.213]    [Pg.203]    [Pg.113]    [Pg.27]    [Pg.16]    [Pg.549]    [Pg.76]    [Pg.434]    [Pg.183]    [Pg.148]    [Pg.361]    [Pg.67]    [Pg.434]    [Pg.15]    [Pg.111]   