Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Dimension and Bases

The two operations introduced by the axioms can occur in combinations. Using the associativity, we define uniquely a linear combination of vectors v , v , with coefficients (real numbers), ,  [Pg.518]

Let us have n vectors Vj, —, v . We say that the vectors are linearly dependent when there exist some real numbers, ,, not all zero and such [Pg.518]

We say that vector space is finite-dimensional when there exists a positive integer n such that any (n+1) vectors Vi, —, v +, are linearly dependent. If so, the smallest number n = N (say) having this property is called the dimension of space the notation is [Pg.518]

Thus there exist some N linearly independent vectors in but any (N+1) vectors are linearly dependent. An arbitrary set of N linearly independent vectors is then called a basis of (N-dimensional) vector space I.  [Pg.518]

Let thus b, , bn constitute a basis of our T Then, clearly, any vector V e P equals some linear combination of the basis vectors, say [Pg.518]


AH of the reactions considered to be useful in the production of hemoglobin-based blood substitutes use chemical modification at one or more of the sites discussed above. Table 2 Hsts the different types of hemoglobin modifications with examples of the most common reactions for each. Differences in the reactions are determined by the dimensions and reactivity of the cross-linking reagents. Because the function of hemoglobin in binding and releasing... [Pg.162]

The objective in selecting a support for a catalytic appHcation is to provide a suitable, stable base for the active catalytic component. The support should be chemically inert so that it does not interfere with the role of the catalytic component, and it should possess acceptable physical properties for the intended apphcation. The support should retain its dimensions and chemical integrity under the conditions necessary to operate the catalytic process. [Pg.193]

On the base of the developed mathematical models was developed regression model of the atomizer efficiency via main design pai ameters such as linear dimensions and operation temperatures. [Pg.84]

Cathodic protection, complete or partial (stem and bow), is arranged by the distribution of the anodes so that the desired current distribution is maintained correctly in the relevant areas. Galvanic anodes, depending on their dimensions and current output, deliver a certain maximum current which depends on the conductivity. The calculated maximum current from Eq. (6-12) based on the driving voltage and grounding resistance is reduced in practice on working anodes due to film for-... [Pg.399]

The data used to generate the maps is taken from a simple statistical analysis of the manufacturing process and is based on an assumption that the result will follow a Normal distribution. A number of component characteristics (for example, a length or diameter) are measured and the achievable tolerance at different conformance levels is calculated. This is repeated at different characteristic sizes to build up a relationship between the characteristic dimension and achievable tolerance for the manufacture process. Both the material and geometry of the component to be manufactured are considered to be ideal, that is, the material properties are in specification, and there are no geometric features that create excessive variability or which are on the limit of processing feasibility. Standard practices should be used when manufacturing the test components and it is recommended that a number of different operators contribute to the results. [Pg.54]

A fume cupboard should be sited to avoid disturbances to the fume cupboard, its operator, and other personnel. It should not interfere with the escape route from the area in the event of an emergency. It should be sited to maximize the working efficiency of the cupboard and the area in which it is installed. Although specified dimensions and layout cannot guarantee performance, the values in Table 10.8 are based on experience and are widely used. [Pg.890]

The user must have experience in thermal analysis and HVAC dimensioning and be familiar with the theoretical principles and details upon which such analysis is based in the program used. Engineering judgment will have to be used for tbe definition of the input parameters. [Pg.1073]

Based on the requirements of the separation, media of suitable pore size, particle size, and surface properties are selected as well as column dimensions and column material. In some cases a suitable combination of media type and column dimensions may be available as a prepacked column. In most cases, this is a more expensive alternative to preparing the column yourself but will provide a consistent quality as assured by the manufacturing and testing procedures of the vendor. The consistent quality may be critical in obtaining reproducible results and may thus be a cost-effective solution. Also, the fact that smaller particle-sized media are more difficult to pack and require special, and expensive, equipment has resulted in that gel filtration media of small particle size, e.g. smaller than 15 /zm, are predominantly supplied as prepacked columns. [Pg.61]

To maximize control in setting tolerances there is usually a minimum and a maximum limit on thickness, based on the process to be used such as those in Tables 3-6 to 3-9. Each plastic has its own range that depends on its chemical structure, composition (additives, etc.), and melt-processing characteristics. Any dimensions and tolerances are theoretically possible, but they could result in requiring special processing equipment, which usually becomes expensive. There are of course products that require and use special equipment such as polycarbonate compact discs (CDs) to meet extremely tight tolerances. [Pg.159]

The more useful types of chirally active bonded phases are those based on the cyclodextrins. There are a number of different types available, some of which have both dispersive or polar groups bonded close to the chirally active sites to permit mixed interactions to occur. This emphasizes the basic entropic differences between the two isomers being separated. A range of such products is available from ASTEC Inc. and a separation of the d and / isomers of scopolamine and phenylephrine are shown in figure 4. The separations were carried out on a cyclodextrin bonded phase (CYCLOBOND 1 Ac) that had been acetylated to provide semi-polar interacting groups in close proximity to the chiral centers of the cyclodextrin. The column was 25 cm long, 4.6 mm in diameter and packed with silica based spherical bonded phase particles 5pm in diameter. Most of the columns supplied by ASTEC Inc. have these dimensions and, consequently, provide a... [Pg.291]

The compressibility of group-IVA and -VIA transition-metal boride powders is measured by the dimensions and weights of the blanks, by measuring the stroke of the punches with a cathetometer, or alternatively by electrical conductivity (based upon the metallic conductivity of most borides). The process of densiheation by pressing is defined by ... [Pg.298]

Unlike traditional textbooks of tribology, in this book we regard boundary lubrication as a limit state of hydrodynamic lubrication when film thickness is down to molecular dimension and independent of the velocity of relative motion. The discussions are based on the existing results, some from literatures but mostly from the authors own work. The topics are mainly focused on the mechanical properties of boundary films, including rheology transitions, molecular ordering, and shear responses. Ordered molecule films, such as L-B films and SAM, are discussed, with emphasis on the frictional performance, energy dissipation and the effects from structural features. Boundary films can be modeled either as a confined substance, or an adsorbed/reacted layer on the... [Pg.94]

This analysis gives satisfactory results concerning the average crystallite sizes even in unfavorable experimental conditions such as overlapped or very weak and noisy peaks, and it allows an easy treatment of non-perfect monochromaticity of the radiation. But, it is important to emphasize that it is almost impossible to obtain the promised detailed description of the crystallite size and strain distributions. This is a fundamental problem related to the adopted procedure that is based on the a priori choice of the peak shape that inevitably imposes the general shape of such distributions [40]. For these reasons, the average dimension and strains remain the only reliable information. [Pg.135]

The surface area and the dimensions and volume of the pores can be determined in many ways. A convenient method is based on measurement of the capacity for adsorption. The experimental techniques do not differ from those used for chemisorption (see Section 3.6.3). The fundamental difference between physi.sorption and chemisorption is that in chemisorption chemical bonds are formed, and, as a consequence, the number of specific sites is measured, whereas in physisorption the bonds are weak so that non-chemical properties, in particular the surface area, are determined. [Pg.97]

The classification of critical points in one dimension is based on the curvature or second derivative of the function evaluated at the critical point. The concept of local curvature can be extended to more than one dimension by considering partial second derivatives. d2f/dqidqj, where qt and qj are x or y in two dimensions, or x, y, or z in three dimensions. These partial curvatures are dependent on the choice of the local axis system. There is a mathematical procedure called matrix diagonalization that enables us to extract local intrinsic curvatures independent of the axis system (Popelier 1999). These local intrinsic curvatures are called eigenvalues. In three dimensions we have three eigenvalues, conventionally ranked as A < A2 < A3. Each eigenvalue corresponds to an eigenvector, which yields the direction in which the curvature is measured. [Pg.149]

The choice of columns used for 2DLC is based upon experience with the sample and resolution required. The HPLC column descriptors of selectivity, resolution, peak capacity, sample capacity, degree of sample recovery, and speed of separation have been discussed previously (Unger et al., 2000). Columns with higher peak capacity and sample capacity (IEC, HIC, NPLC, and RPLC) are preferred in the first dimension, and higher speed columns (SEC and RPLC) are better in the second dimension. This is discussed in detail in Chapters 2 and 6. [Pg.108]

Moment analysis is one of the simplest types of analysis and is useful for measuring the performance of the chromatography. Moments can be used to measure the same things that are measured in ID chromatographic systems these include the first, second, and third moments, which are more accurate than the related peak maximum, peak width, and peak asymmetry. In 2D, however, these values each have a component in each dimension and this can be easily determined in software-based measurement systems. [Pg.120]


See other pages where Dimension and Bases is mentioned: [Pg.255]    [Pg.489]    [Pg.24]    [Pg.1126]    [Pg.518]    [Pg.255]    [Pg.489]    [Pg.24]    [Pg.1126]    [Pg.518]    [Pg.190]    [Pg.268]    [Pg.124]    [Pg.354]    [Pg.103]    [Pg.109]    [Pg.165]    [Pg.510]    [Pg.392]    [Pg.399]    [Pg.221]    [Pg.9]    [Pg.201]    [Pg.72]    [Pg.376]    [Pg.72]    [Pg.897]    [Pg.50]    [Pg.379]    [Pg.561]    [Pg.425]    [Pg.29]    [Pg.519]    [Pg.8]    [Pg.473]    [Pg.122]    [Pg.29]    [Pg.106]   


SEARCH



Base dimensions

© 2024 chempedia.info