Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Digital images filtering

The RRI image of an MP distribution can thus be derived with a digital image subtraction routine, where the intensities obtained for each pixel of the two images are divided by the appropriate filter transmission coefficient. [Pg.96]

Bright DS, Steel EB. Two dimensional top hat filter for extracting spots and spheres from digital images. J Microsc 1987 146 191-200. [Pg.158]

Appropriate electrophoresis systems in various sizes are available from numerous companies. More expensive are the imaging devices, usually consisting of a UV transilluminator and a CC-camera attached to a computer. There are several types of digital image analysers commercially available. Alternatively, one may use ordinary photography (use a red filter and UV-transilluminator) to obtain an image of the gel. [Pg.815]

For the estimation of Chi formation in hairy roots, the root cells were examined on a laser scanning confocal image system attached to a microscope. The filter package with a laser (excitation 568 nm) and a 590-610 nm band pass barrier filter for red fluorescence was employed. Digital image analysis was performed by a computer-aided image processing system with software. [Pg.206]

The application of in situ hybridization (ISH) has advanced from short lived, non-specific isotopic methods, to very specific, long lived, multiple color fluorescent-ISH probe assays (FISH). Improvements in the optics, filter technology, microscopes, cameras, and data handling by software, have allowed for a cost effective FISH setup to be within reach of most researchers. The application of mFISH (multiplex-FISH), coupled to the advances in digital imaging microscopy, have vastly improved the capabilities for non-isotopic detection and analysis of multiple nucleic acid sequences in chromosomes and genes (1). [Pg.75]

Fig. 1. The chemotaxis of human umbilical vein endothelial cells in response to bFGF (50 ng/mL), VEGF (50ng/mL), and the chemokines IL-8 (50 nM) and RANTES (100 nM). The assay was carried out using filters with a pore size of 8 pM, and the migration assay was carried out for 6 h. The results are given as area of the digitized image of the migrated cells (pixels), using a Sony video camera and a Kontron Vidas image analysis system. Fig. 1. The chemotaxis of human umbilical vein endothelial cells in response to bFGF (50 ng/mL), VEGF (50ng/mL), and the chemokines IL-8 (50 nM) and RANTES (100 nM). The assay was carried out using filters with a pore size of 8 pM, and the migration assay was carried out for 6 h. The results are given as area of the digitized image of the migrated cells (pixels), using a Sony video camera and a Kontron Vidas image analysis system.
Equation 11.7 can be used for the weak filter representation of a given digital image. [Pg.272]

One solution to the problem is to increase the ionization probability. This can be done by choosing primary ions with heavy mass, for example, Bi+ or even Ccarbon atoms. The noise level can also be reduced by techniques of digital image processing. For example, a fast Fourier transform technique has been used to remove noise from the image. This technique transforms an image from a space domain to a reciprocal domain by sine and cosine functions. Noise can be readily filtered out in such domain. After a reverse Fourier transform, filtered data produces an image with much less noise. [Pg.245]

Inhibition of Ice Recrystallization. IR inhibition assays were conducted as previously described". Briefly, samples are placed in capillary tubes and snap-frozen at about -35 C. They were then placed in the cryocycler chamber, with the temperature held at -6 C for >16 h. Digital images through crossed polarizing filters were taken of the capillaries immediately after they were placed in the chamber and at the end of the incubation period. Crystal size in the images was compared. Samples were classified as show ing IR inhibition if there was no apparent growth in the crystal size over time. [Pg.90]

DIS is a context-dependent acronym for either digital imaging spectrophotometer or digital imaging spectroscopy. In earlier publications, DIS is synonymous with FAS, an acronym for filter array spectrophotomer. [Pg.733]


See other pages where Digital images filtering is mentioned: [Pg.273]    [Pg.494]    [Pg.273]    [Pg.494]    [Pg.156]    [Pg.522]    [Pg.192]    [Pg.167]    [Pg.223]    [Pg.130]    [Pg.229]    [Pg.80]    [Pg.3]    [Pg.256]    [Pg.306]    [Pg.78]    [Pg.231]    [Pg.22]    [Pg.79]    [Pg.217]    [Pg.223]    [Pg.281]    [Pg.264]    [Pg.195]    [Pg.575]    [Pg.346]    [Pg.141]    [Pg.216]    [Pg.215]    [Pg.164]    [Pg.185]    [Pg.98]    [Pg.115]    [Pg.130]    [Pg.481]    [Pg.166]    [Pg.105]    [Pg.103]    [Pg.538]    [Pg.72]    [Pg.32]    [Pg.64]   
See also in sourсe #XX -- [ Pg.58 ]




SEARCH



Digital filtering

Digital images

© 2024 chempedia.info