Big Chemical Encyclopedia

Chemical substances, components, reactions, process design ...

Articles Figures Tables About

Devices considerations

Many processes require equipment designed to rigid specifications together with automatic control and safety devices. Consideration should be given to the control, and limitation of the effects, of equipment malfunction or maloperation including ... [Pg.253]

Analysis time is typically of the order of minutes to hours depending on the sample. Normally the time spent in actual AMS analysis is not the constraining factor, but rather sample purification prior to the spectrometric analysis. Accelerator mass spectrometers are space demanding facilities that typically occupy hundreds of square meters. Normally, dedicated personnel operate the device. Considerable effort is directed into refining the methods to allow operation by smaller, less costly facilities. [Pg.65]

This presentation addresses tissue engineering and how it relates to biomaterials and medical devices. Consideration is given to risk analysis and risk management in tissue engineering, and current proposals are discussed for an approach to the regulation of tissue engineering products and regulatory processes in the European Union. EUROPEAN COMMUNITY EUROPEAN UNION UK WESTERN EUROPE... [Pg.55]

Roberts ME, Sokolov AN, Bao ZN (2009) Material and device considerations for organic thin-film transistor sensors. J Mater Chem 19 3351... [Pg.204]

The desire to increase P values above those of molecules used in the earliest materials has led to the exploration of organic compounds as the active components of second order NLO devices. Considerable effort has been expended in the synthesis and analysis of candidate molecules, which are largely donor-acceptor substituted conjugated n systems. (2) Examples of compound classes whose members display large nonresonant P include azo dyes, stilbenes, polyenes, merocyanines, stilbazolium salts, and quinoid... [Pg.270]

High-viscosity liquids If the system is filled with highly viscous liquids such as polymers, the rupture disc can be considered because the SRV will have to be equipped with steam jackets, which will increase the price of the device considerably. [Pg.139]

Design of junction devices. Considerable effort has been applied to the design of junction devices for reference electrodes and salt bridges. For highest stability and reproducibility, the junction should be formed within a cylindrical tube by one of the methods described in Ref. 10 or 11. Such junctions can be... [Pg.178]

General Biologic/Device Considerations The following is a list of potential unique considerations for assessing the safety of biologic-device combination products ... [Pg.795]

As expected, decreasing the injection barriers and adding electron-transporting molecules improves the efficiency of the device considerably. Today s best efficiencies have been reported for the structure ITO/PEDT PSS/PVK OXD-7 Firpic(12wt. %)/Ca/Al. As shown by the data in Fig. 11.19, the maximum EQE was 5.9% (corresponding to 12 cd/A) and the peak PCE was 6.4 lm/W [84]. [Pg.357]

SPME is a very simple and efficient sample preparation method, requiring no solvent (at least for GC applications). Following its introduction (Belardi 1989 Arthur 1990), SPME has been widely used in different fields of analytical chemistry since its first applications to environmental and food analysis. A recent extensive review (Vas 2004) covers the principles and applications of the technique. Other reviews (Queiroz 2004 Hinshaw 2003 Wang 2004 O Reilly 2005 Ouyang 2006) describe special aspects. All conventional steps of extraction, concentration, possibly derivatization, and transfer to a GC are integrated into one step and one device, considerably simphf5dng the sample preparation procedure. (If HPLC is to be used, SPME more closely resembles conventional SPE in a special miniaturized format.)... [Pg.132]

Electrochemists should consider the poor performance of stacks of batteries and fuel cells connected in series, compared to the performance of single cells. The solution to this problem is probably by microprocessor monitoring and control of each of the cells in the stack, making it possible to disconnect a malfunctioning cell for later replacement. Although not an electrochemical problem per se, its solution could increase the viability of electrochemical energy conversion devices considerably. [Pg.71]

As PE is a popular material for disposable medical devices, considerable effort has been applied to assess its response to radiation sterilisation. In experiments up to 75 and 200 kGy, it has been reported that most mechanical properties improve with radiation exposure. Slight discoloration due to phenolic-based antioxidants and particularly in combination with HAS was one detrimental aspect observed. Radiation resistance is measured by changes in properties. Bulk properties such as HDT and failure by yielding will be insensitive to surface degradation and will therefore imply high radiation resistance. Tensile properties are less sensitive to surface degradation than flexural ones. [Pg.83]

Device considerations Can the device a user is on handle certain types of content ... [Pg.146]


See other pages where Devices considerations is mentioned: [Pg.275]    [Pg.383]    [Pg.78]    [Pg.783]    [Pg.797]    [Pg.497]    [Pg.340]    [Pg.489]    [Pg.501]    [Pg.154]    [Pg.254]    [Pg.54]    [Pg.775]    [Pg.38]    [Pg.333]    [Pg.156]    [Pg.299]    [Pg.49]    [Pg.292]    [Pg.347]    [Pg.185]    [Pg.111]   


SEARCH



Basic MR Device Design Considerations

Considerations when applying device

Device fabrication, consideration

Device fabrication, consideration molecular electronics

© 2024 chempedia.info